Plan Review Details - Permit 12030659
Plan Review Stops For Permit 12030659
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-04-17 Cont ID  
Sent By jwitmer Date 2012-04-17 Time 14:36 Rev Time 0.00
Received By jwitmer Date 2012-04-17 Time 14:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-04-02 Cont ID  
Sent By jwitmer Date 2012-04-02 Time 16:32 Rev Time 0.00
Received By jwitmer Date 2012-04-02 Time 15:50 Sent To  
Notes
2012-04-02 16:31:57BUILDING PLAN REVIEW
 PERMIT: 12030659
 ADD: 1020 CHAROLETTE AVE
 CONT: HOLT CONTRACTORS
 TEL: (561)2129099
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) CONTRACTOR TO TAKE RESPONSIBILITY FOR THEIR PLANS.
 PRINT THEIR NAME, SIGN THEIR NAME AND LICENSE NUMBER ON
 THE PLANS. @007/09 FBC-B 106.1.
  
 2) MISSING INFORMATION ON WALL SECTION A-A:
 2A) PLANS DO NOT IDENTIFY THE TYPE OF LEDGER ATTACHED
 TO THE BLOCK WALL.
 2B) PLANS DO NOT IDENTIFY THE TYPE OF ANCHOR, DIAMETER,
 LENGTH NOR SPACING.
 2C) PLANS DO NOT IDENTIFY THE TYPE OF BUCKET OR HANGER
 USED TO HANG THE 2 X 10'S.
 2D) PLANS DO NOT INDICATE NEITHER TOP NOR BOTTOM PLATES
 NOR THE ANCHORING OF THE BOTTOM PLATE TO THE CONCRETE
 FLOOR.
 2E) PLANS DO NOT INDICATE IF THE NEWLY FORMED SPACE
 ABOVE THE NEW ROOM WILL BE USED FOR A MEZZANINE FOR
 STORAGE, IF SO PROVIDE THE DESIGNED STORAGE IN PSF.
 FBC-B 1104.1-2.
 2F) TO THE CODE EDITION THIS PLAN WAS DESIGNED TOO.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2012-04-05 Cont ID  
Sent By rlecky Date 2012-04-05 Time 17:23 Rev Time 0.00
Received By rlecky Date 2012-04-05 Time 17:21 Sent To  
Notes
2012-04-05 17:25:33SEPERATE PERMIT HAS BEEN SUBMITTED FOR THE ELECTRIC
 #12040066. RL

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2012-04-24 Cont ID  
Sent By wjolin Date 2012-04-24 Time 11:26 Rev Time 0.00
Received By wjolin Date 2012-04-24 Time 11:23 Sent To M
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-04-04 Cont ID  
Sent By wjolin Date 2012-04-04 Time 12:13 Rev Time 0.00
Received By wjolin Date 2012-04-04 Time 11:13 Sent To  
Notes
2012-04-04 12:13:131020 CHARLOTTE AVENUE
 PERMIT #12030659
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 INDICATE ANY CHEMICALS OR FUELS TO BE USED IN THE GLASS
 ART CARVING ROOM.
  
 PROVIDE ADDITIONAL INFORMATION (FUEL, VENTING, ETC.) ON
 THE NEW KILN SHOWN ON THE PLAN.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-04-25 Cont ID  
Sent By hmoser Date 2012-04-25 Time 14:37 Rev Time 0.00
Received By hmoser Date 2012-04-17 Time 14:26 Sent To  
Notes
2012-04-17 14:26:16B08

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-04-09 Cont ID  
Sent By hmoser Date 2012-04-09 Time 09:40 Rev Time 0.00
Received By hmoser Date 2012-03-28 Time 10:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-04-25 Cont ID  
Sent By hmoser Date 2012-04-25 Time 14:36 Rev Time 0.00
Received By hmoser Date 2012-04-25 Time 14:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-04-09 Cont ID  
Sent By hmoser Date 2012-04-09 Time 09:39 Rev Time 0.00
Received By hmoser Date 2012-04-09 Time 09:34 Sent To  
Notes
2012-04-09 09:39:47PLANS DENIED
 PROVIDE VENTILATION ON THE PLANS FOR THE KILN AND DUST
 COLLECTOR.
 PROVIDE PIPING ON THE PLANS FOR THE COMPRESSOR.
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2012-04-03 Cont ID  
Sent By eschneid Date 2012-04-03 Time 16:53 Rev Time 0.25
Received By eschneid Date 2012-04-03 Time 12:14 Sent To  
Notes
2012-04-03 16:56:30INTERIOR WORK ONLY LESS THAN 50% OF STRUCTURE VALUE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved