| Plan Review Stops For Permit 12030659 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-04-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-04-17 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-04-17 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-04-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-04-02 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-04-02 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2012-04-02 16:31:57 | BUILDING PLAN REVIEW | | | PERMIT: 12030659 | | | ADD: 1020 CHAROLETTE AVE | | | CONT: HOLT CONTRACTORS | | | TEL: (561)2129099 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) CONTRACTOR TO TAKE RESPONSIBILITY FOR THEIR PLANS. | | | PRINT THEIR NAME, SIGN THEIR NAME AND LICENSE NUMBER ON | | | THE PLANS. @007/09 FBC-B 106.1. | | | | | | 2) MISSING INFORMATION ON WALL SECTION A-A: | | | 2A) PLANS DO NOT IDENTIFY THE TYPE OF LEDGER ATTACHED | | | TO THE BLOCK WALL. | | | 2B) PLANS DO NOT IDENTIFY THE TYPE OF ANCHOR, DIAMETER, | | | LENGTH NOR SPACING. | | | 2C) PLANS DO NOT IDENTIFY THE TYPE OF BUCKET OR HANGER | | | USED TO HANG THE 2 X 10'S. | | | 2D) PLANS DO NOT INDICATE NEITHER TOP NOR BOTTOM PLATES | | | NOR THE ANCHORING OF THE BOTTOM PLATE TO THE CONCRETE | | | FLOOR. | | | 2E) PLANS DO NOT INDICATE IF THE NEWLY FORMED SPACE | | | ABOVE THE NEW ROOM WILL BE USED FOR A MEZZANINE FOR | | | STORAGE, IF SO PROVIDE THE DESIGNED STORAGE IN PSF. | | | FBC-B 1104.1-2. | | | 2F) TO THE CODE EDITION THIS PLAN WAS DESIGNED TOO. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2012-04-05 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-04-05 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-04-05 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2012-04-05 17:25:33 | SEPERATE PERMIT HAS BEEN SUBMITTED FOR THE ELECTRIC | | | #12040066. RL |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2012-04-24 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-04-24 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-04-24 |
Time |
11:23 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2012-04-04 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-04-04 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-04-04 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2012-04-04 12:13:13 | 1020 CHARLOTTE AVENUE | | | PERMIT #12030659 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | INDICATE ANY CHEMICALS OR FUELS TO BE USED IN THE GLASS | | | ART CARVING ROOM. | | | | | | PROVIDE ADDITIONAL INFORMATION (FUEL, VENTING, ETC.) ON | | | THE NEW KILN SHOWN ON THE PLAN. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-04-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-04-25 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-04-17 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-04-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-04-09 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-03-28 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-04-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-04-25 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-04-25 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-04-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-04-09 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-04-09 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2012-04-09 09:39:47 | PLANS DENIED | | | PROVIDE VENTILATION ON THE PLANS FOR THE KILN AND DUST | | | COLLECTOR. | | | PROVIDE PIPING ON THE PLANS FOR THE COMPRESSOR. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2012-04-03 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2012-04-03 |
Time |
16:53 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2012-04-03 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2012-04-03 16:56:30 | INTERIOR WORK ONLY LESS THAN 50% OF STRUCTURE VALUE. |
|
|