|
 |
 |
 |
 |
 |
Plan Review Details - Permit 12030652
| Plan Review Stops For Permit 12030652 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-04-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-05 |
Time |
07:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-04 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2012-04-04 16:35:21 | SENT TO R MCD DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-03-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-28 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-27 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2012-03-27 11:46:44 | TO RM DESK | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-04-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-05 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-05 |
Time |
06:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-03-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-28 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-28 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2012-03-28 11:01:58 | 2007 FBC W/2009 REVISIONS | | | | | | MECHANICAL REVISION DENIED | | | | | | 1) THE ENGINEER THAT SIGNED AND SEALED THE REVISION, | | | FERNANDO GOMEZ-PINA, IS NOT THE DESIGNER OF RECORD, | | | HAROLD TUSSLER, THAT SIGNED AND SEALED THE ORIGINAL | | | PLANS. SEE FS 471 AND FAC 61G15-27 FOR SUCCESSOR | | | ENGINEER ADOPTING AS HIS OWN THE WORK OF ANOTHER | | | ENGINEER. | | | | | | 2) THE ORIGINAL PLANS INDICATE THAT THE ENTIRE HVAC | | | SYSTEM WAS TO BE REPLACED, INCLUDING THE AIR HANDLER | | | AND CONDENSING UNIT. THE REVISION INDICATES THAT ONLY | | | THE DUCKWORK WAS REPLACED AND NO EQUIPMENT SCHEDULE IS | | | PROVIDED ON THE REVISED PLANS. PLEASE CLARIFY. CITY | | | AMENDMENTS 106.1.1 | | | | | | 3) THE 10" TRANSFER DUCT FROM THE MASTER SUITE IS | | | UNDERSIZED. FBCR M1602.4 REQUIRES THAT ALL SUPPLY AIR | | | INTO THE MASTER SUITE IS TO BE CONSIDERED WHEN SIZING | | | THE TRANSFER DUCTS. THEREFORE, THE TRANSFER DUCT SHOULD | | | BE 12". PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |