| 2012-04-03 14:14:14 | BUILDING PLAN REVIEW |
| | PERMIT: 12030566 |
| | ADD: 6901 OKEECHOBEE BLVD UNIT C15 |
| | CONT: YORK ELECTRIC |
| | TEL: (786)287-7380 |
| | |
| | 2010 FLORIDA BUILDING CODE W/ |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) PLEASE CORRECT JOBSITE LOCATION ON THE PLANS, FROM |
| | ROYAL PALM BEACH TO WEST PALM BEACH. 2010 WEST PALM BCH |
| | ADMINISTRATIVE CODE 106.1.1. LOCATION. |
| | |
| | 2) CONTRACTOR TO TAKE RESPONSIBILITY FOR THE |
| | CONSTRUCTION DOCUMENT DESIGN BY SIGNING YOUR NAME TO |
| | THE PLANS, PRINTING YOUR NAME AND ELECTRICAL LICENSE |
| | NUMBER. 2010 WEST PALM BCH ADMINISTRATIVE CODE 106.1. |
| | |
| | 3) THE PLAN INDICATES USE OF 1/4" ALUMINUM STUDS. HOW |
| | ARE THE STUDS FASTENED TO THE PVC LETTERS? HOW ARE THE |
| | STUDS TO BE ANCHORED TO THE WALL? WHAT TYPE OF MATERIAL |
| | IS THE FACADE CONSTRCUTED FROM? |
| | |
| | 4) MISSING WIND DESIGN CRITERIA? |
| | 1609.6.2 WIND DESIGN PROCEDURES |
| | 1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE |
| | ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION. |
| | |
| | 2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH SECTION1609.5. |
| | |
| | 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.4. |
| | |
| | 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| | SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4 |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |