Plan Review Details - Permit 12030528
Plan Review Stops For Permit 12030528
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-04-19 Cont ID  
Sent By shill Date 2012-04-19 Time 11:32 Rev Time 0.00
Received By shill Date 2012-04-19 Time 11:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-04-02 Cont ID  
Sent By shill Date 2012-04-02 Time 15:47 Rev Time 0.00
Received By shill Date 2012-04-02 Time 15:47 Sent To  
Notes
2012-04-02 15:51:32****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. GOVERNING CODE CHANGED TO FBC 2010 EFFECTIVE MARCH
 15, 2012. PLEASE REVISE ENGINEERING.
  
 2. PLEASE REVISE ITEM 6 ON ENGINEERING; IT STATES THAT
 FABRIC IS TO BE REMOVED AT 75MPH (90 MPH 3 SECOND
 GUST). THIS IS NOT ACCURATE, 75MPH IS A 3 SECOND GUST,
 NOT SUSTAINED, AND IS NOT THE SAME AS 90MPH. FBC
 3105.4.2.1.
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-04-19 Cont ID  
Sent By shill Date 2012-04-19 Time 11:32 Rev Time 0.00
Received By shill Date 2012-04-12 Time 11:17 Sent To  
Notes
2012-04-13 11:18:17INCOMING SENT TO S HILL DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-04-02 Cont ID  
Sent By shill Date 2012-04-02 Time 15:51 Rev Time 0.00
Received By shill Date 2012-03-21 Time 14:18 Sent To  
Notes
2012-03-21 14:19:15SENT TO ZONING BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2012-03-28 Cont ID  
Sent By eschneid Date 2012-03-28 Time 17:48 Rev Time 0.25
Received By eschneid Date 2012-03-28 Time 17:48 Sent To B
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved