| Plan Review Stops For Permit 12030454 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-05-15 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-05-15 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-04-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-04-09 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-04-09 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2012-04-09 16:12:29 | BUILDING PLAN REVIEW | | | PERMIT: 12030454 | | | ADD: 319 CLEMATIS ST 1ST/ 2ND FLOOR COMMON AREAS | | | CONT: CLAY KOHLMEYER GENERAL CONTRACTING | | | TEL: (561)719-3429 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | 1) PLANS INDICATE THEY ARE DESIGNED TO THE 2007/09 FBC, | | | AS OF MARCH 15, 2012 PLANS SUBMITTED FOR PERMIT ARE TO | | | BE DESIGNED TO THE FAMILY OF 2010 FBCODES. | | | | | | 2) THE COVER SHEET & LIFE SAFETY SHEET INDICATE THIS | | | BUILDING TO BE A TYPE II-B CONSTRUCTION. 2007/09 FBC-B | | | TABLE 503 TO BE A 10 STORY BUILDING WITH BUSINESS | | | OCCUPANCIES THE BUILDING TYPE WOULD BE A MINIMUM OF A | | | TYPE IB. | | | | | | 3) THE PLANS ARE DEFICIENT IN INDICATING RATED WALLS, | | | STAIRWELLS, FIRE PUMP ROOMS, TENANT SEPERATION WALLS, | | | THERE ARE NO CUT SECTION OF WALLS INDICATING LISTED | | | ASSEMBLIES AND HOUR OF FIRE RATING FOR FIRE RATED WALLS | | | AND OPENING PROTECTIVES. FBC-B 707,708, 709 & TABLE | | | 715.4. | | | | | | 4) PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-B 713.6 | | | "FIRE & SMOKE BARRIERS PROTECT ALL OPENINGS". | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-03-26 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-03-26 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-03-26 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2012-05-10 |
|
|
Cont ID |
|
| Sent By |
ddaniels |
Date |
2012-05-10 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
ddaniels |
Date |
2012-05-10 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2012-05-10 12:43:04 | 05/10/2012 PLANS REVIEWED BY FIRE **APPROVED** | | | | | | COMMENTSS ADDRESSED IN LETTER TO BUILDING. | | | | | | DERRICK L. DANIELS, BATTALION CHIEF | | | WEST PALM BEACH FIRE RESCUE | | | OFFICE OF THE FIRE MARSHAL | | | (561) 805-6722 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2012-04-10 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-04-10 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-04-10 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2012-04-10 12:48:43 | 319 CLEMATIS STREET | | | PERMIT #12030454 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SHEET A2.0: INDICATE THE HOURLY FIRE RESISTANCE RATING | | | OF THE NEW FIRE RATED GLASS WALLS AND GLASS DOOR. DOOR | | | SHALL BE SELF CLOSING AND POSITIVE LATCHING. SUBMIT | | | PRODUCT DATA. | | | | | | EACH NEW SMOKE OR FIRE-RATED WALL/PARTITION SHALL BE | | | PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING | | | FIRE/SMOKE BARRIER-PROTECT ALL OPENINGS. CHARACTERS | | | SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN | | | WIDTH. | | | | | | ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO | | | THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION | | | DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. ALL | | | DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF | | | THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | MODIFICATION OF THE FIRE SPRINKLER SYSTEM AND FIRE | | | ALARM SYSTEM. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-15 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-05-04 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2012-05-04 16:30:49 | EXPEDITED | | | B--17 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-04-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-04-12 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-03-19 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2012-03-22 17:32:15 | SENT TO B17 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-05-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-15 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-05-15 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-04-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-04-06 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-04-06 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2012-04-06 13:53:23 | PLANS DENIED | | | PROVIDE WALL SCHEDULE ON PLANS. WHAT WALLS ARE RATED IF | | | ANY. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-03-30 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-03-30 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-03-30 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2012-04-06 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2012-04-06 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2012-04-06 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2012-04-06 09:16:21 | INTERIOR RENOVATIONS ONLY. |
|
|