Plan Review Details - Permit 12030359
| Plan Review Stops For Permit 12030359 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2012-05-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-21 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-21 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2012-05-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-02 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-02 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2012-05-02 10:20:16 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PLEASE SEE SHEET 1 OF THE PRODUCT APPROVAL FOR | | | SHUTTER TO GLASS SEPARATION REQUIREMENTS AND REVISE THE | | | INSTALLATION SCHEDULE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-04-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-04-16 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-04-16 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2012-04-16 09:47:07 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM | | | /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF) | | | | | | IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 606.4, | | | PROVIDE CALCULATIONS. | | | | | | CONTRACTOR'S RESUBMITTAL STATES THAT CUSTOMER HAS | | | EXISTING ACCORDIONS. PROVIDE A PERMIT NUMBER FOR THE | | | FBC COMPLIANT SHUTTERS, UNABLE TO FIND IN OUR RECORDS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-03-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-03-28 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-03-28 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2012-03-28 17:00:50 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM | | | /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF) | | | | | | IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 606.4, | | | PROVIDE CALCULATIONS. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2012-05-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-21 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-05-14 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2012-05-14 15:04:09 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-05-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-05-02 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-04-23 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2012-04-23 11:10:56 | TO SH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-04-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-04-16 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-04-16 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-03-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-03-28 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-03-14 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2012-03-15 15:38:21 | UNDER 5 K BUILDING | | 2012-03-15 07:55:04 | SENT TO MISC 1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |