Plan Review Details - Permit 12030345
Plan Review Stops For Permit 12030345
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2012-11-27 Cont ID  
Sent By rmcdouga Date 2012-11-27 Time 16:43 Rev Time 0.00
Received By rmcdouga Date 2012-11-27 Time 16:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2012-11-26 Cont ID  
Sent By rmcdouga Date 2012-11-26 Time 10:58 Rev Time 0.00
Received By rmcdouga Date 2012-11-26 Time 10:56 Sent To  
Notes
2012-11-26 11:48:132007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE
 SIGNED AND DATED BY THE PREPARER. THE ENERGY CALCS.
 HAVE THE ATTIC INSULATION AS R-0.1 AND THE PLANS SHOW
 R-30 ATTIC INSULATION. PLEASE CORRECT. 2007 FBC ENERGY
 GLITCH AMENDMENTS N1100.2
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-10-19 Cont ID  
Sent By rmcdouga Date 2012-10-19 Time 16:06 Rev Time 0.00
Received By rmcdouga Date 2012-10-19 Time 16:06 Sent To  
Notes
2012-10-19 16:17:162007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE
 SIGNED AND DATED BY THE PREPARER AND THE OWNER/AGENT.
 2007 FBC ENERGY GLITCH AMENDMENTS N1100.2
  
 2) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 EXTERIOR DOORS AND WINDOWS, STRUCTURAL MULLIONS AND
 ROOFING MATERIAL AS REQUIRED BY DCA RULE 9B-72.
  
 3) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR
 THE PROJECT. CITY AMENDMENTS 106.3.3
  
 4) AN IMPACT FEE REVIEW IS REQUIRED BY PALM BEACH
 COUNTY. SIGN OUT ONE SET OF THE PLANS AN TAKE THEM TO
 PALM BEACH COUNTY FOR REVIEW. SUBMIT THE STAMPED PLANS
 AND A COPY OF THE IMPACT FEE RECEIPT TO THE CITY OF WPB
 BUILDING DEPARTMENT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-04-13 Cont ID  
Sent By jroach Date 2012-10-18 Time 12:01 Rev Time 0.00
Received By rmcdouga Date 2012-04-11 Time 07:47 Sent To  
Notes
2012-04-11 07:55:342007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO SETS OF A SUBSURFACE SOIL TEST TO
 DETERMINE THE BEARING CAPACITY OF THE SOIL. FBC R401.4
  
 2) THE STRUCTURE IS LOCATED IN A 140 MPH WINDSPEED AND
 IS EXPOSURE CATEGORY C. PLEASE SPECIFY THIS DESIGN
 REQUIREMENT INFORMATION ON THE PLANS.FBC R301.1 AND
 R301.2.1.4.3
  
 3) THE STRUCTURE IS LOCATED WITHIN 600 FEET OF THE
 INTERCOASTAL WATERWAY WHICH REQUIRES THE ROOF SHEATHING
 UPLIFT AND ROOF TO WALL UPLIFT LOADS TO BE INCREASED BY
 20 PERCENT BY FBC R301.2.1.4.3 (2).
  
 4) THE CONSTRUCTION TYPE SPECIFIED ON THE PLANS IS TYPE
 III-B. THIS TYPE OF CONSTRUCTION REQUIRES 2 HOUR FIRE
 RATED EXTERIOR WALLS. THE COMMON CONCRETE BLOCK DOES
 NOT PROVIDE A TWO HOUR FIRE RATING. SHOW HOW THE
 REQUIRED RATING WILL BE ACHIEVED. NOTE: THE LEAST
 RESTRICTIVE ALLOWABLE CONSTRUCTION TYPE FOR THIS
 STRUCTURE IS TYPE V-B WHICH DOES NOT REQUIRE ANY FIRE
 RATED ASSEMBLIES. YOU MAY WISH TO DECLARE THIS
 CONSTRUCTION TYPE ON THE PLANS.
  
 5) SUBMIT TWO COPIES OF A SURVEY / SITE PLAN THAT
 INDICATES THE DISTANCE TO PROPERTY LINES AND OTHER
 STRUCTURES LOCATED ON THE SAME LOT. FBC R302.1
  
 6) THE DRAWING INDEX ON PLAN SHEET A0.0 LISTS A SHEET
 S-1.0 FOUNDATION PLAN AND DETAILS WHICH WAS MISSING
 FROM THE PLANS. PLEASE SUBMIT MISSING PLANS. CITY
 AMENDMENTS 106.3.5.4
  
 7) SHEET A-3.0 WAS ALSO LISTED IN THE DRAWING INDEX BUT
 MISSING FROM THE PLANS. PLEASE SUBMIT MISSING PLANS.
 CITY AMENDMENTS 106.3.5.4
  
 8) PROVIDE WALL SECTIONS AND A WALL SCHEDULE
 IDENTIFYING THE WALL TYPES ON THE PLANS. CITY
 AMENDMENTS 106.3.5.4
  
 9) SUBMIT A WINDOW AND DOOR SCHEDULE ON THE PLANS. CITY
 AMENDMENTS 106.3.5.4
  
 10) SPECIFY THE REQUIRED EXTERIOR DOOR AND WINDOW
 DESIGN PRESSURES ON THE PLANS. FBC R301.2.1
  
 11) CALL OUT THE COLUMN TYPES AT THE LOCATIONS ON THE
 PLANS. CITY AMENDMENTS 106.3.5.4
  
 12) SPECIFY THE CONNECTORS THAT WILL BE USED TO ATTACH
 THE NEW TRUSSES AT THE EXISTING WALLS. CITY AMENDMENTS
 106.3.5.4
  
 13) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE
 SIGNED AND DATED BY THE PREPARER AND THE OWNER/AGENT.
 2007 FBC ENERGY GLITCH AMENDMENTS N1100.2
  
 14) ICYNENE SPRAY FOAM INSULATION IS TYPICALLY APPLIED
 TO THE UNDERSIDE OF THE ROOF SHEATHING WITH AN
 UN-VENTED ATTIC. THE ENERGY CALCULATIONS SPECIFY A
 VENTED ATTIC. PLEASE CLARIFY. CITY AMENDMENTS 106.1.1
  
 15) SUBMIT TWO COPIES OF MANUFACTURES SPECIFICATIONS AN
 EVALUATION REPORT FOR THE ICYNENE SPRAY FOAM
 INSULATION. FBC R314
  
 16) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 EXTERIOR DOORS AND WINDOWS, STRUCTURAL MULLIONS AND
 ROOFING MATERIAL AS REQUIRED BY DCA RULE 9B-72.
  
 17) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR
 THE PROJECT. CITY AMENDMENTS 106.3.3
  
 18) PLEASE PROVIDE A RESPONSE LETTER INDICATING HOW
 EACH OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-03-20 Cont ID  
Sent By rlecky Date 2012-03-20 Time 11:30 Rev Time 0.00
Received By rlecky Date 2012-03-20 Time 10:14 Sent To  
Notes
2012-03-20 11:17:03PLANS REDLINED FOR ADDITIONAL REQUIREMENTS.
  
 ROBERT LECKY
 ELECTRIC PLANS EXAMINER
 [email protected]
 561-805-6718
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-11-26 Cont ID  
Sent By rmcdouga Date 2012-11-26 Time 10:58 Rev Time 0.00
Received By rmcdouga Date 2012-11-16 Time 15:48 Sent To  
Notes
2012-11-19 15:49:14GAVE TO ROBBIE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-10-31 Cont ID  
Sent By lmartine Date 2012-10-19 Time 16:48 Rev Time 0.00
Received By lmartine Date 2012-10-11 Time 08:46 Sent To  
Notes
2012-10-12 08:47:05SENT TO R MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-04-13 Cont ID  
Sent By rmcdouga Date 2012-04-13 Time 14:45 Rev Time 0.00
Received By rmcdouga Date 2012-03-15 Time 14:50 Sent To  
Notes
2012-03-15 14:50:45R--3

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2012-11-26 Cont ID  
Sent By rmcdouga Date 2012-11-26 Time 10:55 Rev Time 0.00
Received By rmcdouga Date 2012-11-26 Time 10:55 Sent To  
Notes
2012-11-26 10:56:37MU-2012-19850

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-04-10 Cont ID  
Sent By rmcdouga Date 2012-04-10 Time 11:11 Rev Time 0.00
Received By rmcdouga Date 2012-04-10 Time 11:11 Sent To  
Notes
2012-04-10 11:12:51AN IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-04-11 Cont ID  
Sent By rmcdouga Date 2012-04-11 Time 07:47 Rev Time 0.00
Received By rmcdouga Date 2012-04-11 Time 07:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-04-10 Cont ID  
Sent By rmcdouga Date 2012-04-10 Time 11:11 Rev Time 0.00
Received By rmcdouga Date 2012-04-10 Time 11:11 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2012-10-18 Cont ID  
Sent By jroach Date 2012-10-18 Time 11:58 Rev Time 0.00
Received By jroach Date 2012-10-18 Time 11:58 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2012-03-22 Cont ID  
Sent By jroach Date 2012-03-22 Time 10:56 Rev Time 0.00
Received By jroach Date 2012-03-22 Time 09:25 Sent To  
Notes
2012-03-22 11:01:31ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 03.22.2012
 PERMIT NO.: 12030345
 ADDRESS: 216 31ST STREET
 CONTRACTOR/CONTACT: JONATHAN FOGT
 TELEPHONE NO.: 561.863.6039
 SCOPE OF REVIEW: ADDITION OF ONE BEDROOM AND LIVING
 ROOM TO EXISTING RESIDENCE.
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. AS THE VALUE OF THE PROPOSED IMPROVEMENTS EXCEEDS 50
 PERCENT OF THE ASSESSED VALUE OF THE STRUCTURE, THE
 PROPERTY SHALL BE BROUGHT IN COMPLIANCE WITH ARTICLE
 XIV (LANDSCAPING) OF THE CITY'S ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDRS).
  
  A LANDSCAPE PERMIT APPLICATION SHALL BE SUBMITTED WITH
 TWO (2) COPIES OF A LANDSCAPE PLAN, AND A CERTIFIED
 COST ESTIMATE. THE LANDSCAPE PLAN SHALL INDICATE ALL
 EXISTING AND PROPOSED TREES/SHRUBS/GROUNDCOVER/ETC AND
 A TABULATION TABLE INDICATING COMPLIANCE WITH ARTICLE
 XIV.
  
  IF THE EXISTING LANDSCAPING CURRENTLY CONFORMS TO THE
 MINIMUM STANDARDS OF ARTICLE XIV AND NO ADDITIONAL WORK
 IS NEEDED, SIMPLY PROVIDE A PLAN INDICATING ALL OF THE
 EXISTING LANDSCAPING, ALONG WITH A TABULATION TABLE,
 INDICATING COMPLIANCE WITH SUCH.
  
 2. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY
 SHALL BE PROVIDED.
  
 3. TWO (2) COPIES OF A SITE PLAN SHALL BE PROVIDED. THE
 SITE PLAN SHALL NOTE THE LOCATION OF THE ALL OF THE
 EXISTING AND PROPOSED IMPROVEMENTS. DIMENSIONS SHALL BE
 PROVIDED FROM THE PROPOSED ADDITION TO ALL PROPERTY
 LINES.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  