| Plan Review Stops For Permit 12030334 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2012-08-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-08-01 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-08-01 |
Time |
12:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2012-07-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-07-05 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-07-05 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2012-07-05 12:37:37 | BUILDING PLAN REVIEW | | | PERMIT: 12030334 | | | ADD: 2275 PALM BEACH LAKES BLVD | | | SHILOH FAMILY WORSHIP CENTER - PHASE II | | | CONT: CUTTING EDGE BUILDING SYSTEMS, INC | | | TEL: (561)282-8265 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | THE THIRD SUBMITTAL THE NEW SHEETS HAVE NOT BEEN | | | INSERTED INTO THE PLANS, AS REVIEWED NOT COMPLETE SETS | | | OF PLANS. | | | | | | 1) COMPLIED. | | | | | | 2) COMPLIED. PLANS INDICATE THIS TENANT SPECE TO BE | | | FIRE SPRINKLERED FIRE SPRINKLER LAYOUT IS INDICATED ON | | | A2.0 WITH NEW FIRE SPRINKLER NOTE SHOP DRAWINGS TO | | | FOLLOW WITH HYDROLIC CALCULATIONS. | | | | | | 3) COMPLIED. | | | | | | 4) COMPLIED. | | | | | | 5) PROVISO: SHEET A6.0 & A6.1 INDICATES CLOUDS AS PART | | | OF A ISOLATED CEILING DESIGN WITHIN THE ASSEMBLY | | | OCCUPANCY. PLEASE PROVIDE DETAILS ON WHAT TYPE OF | | | MATERIALS THIS SYSTEM IS COMPOSED OF, HOW IT IS TO BE | | | HUNG, AND TO WHAT THE CLOUD SYSTEM IS TO BE ATTACHED? | | | ADDITIONAL INFORMATION IS REQUIRED? 106.1.2. SHOP | | | DRAWINGS WILL BE REQUIRED TO BE REVIEWED BY THE | | | DESIGNER OF RECORD BEFORE SUBMITTING THEM TO THE | | | BUILDING DEPARTMENT. | | | | | | 6) THIRD REVIEW, NEW COMMENT, THE NEW A1.0 SHEET IS | | | MISSING WALL TAGS FOR WALLS THAT WERE CHANGED AS PART | | | OF THIS REVISION, EXAMPLE STORAGE ROOM WALLS HAVE THE | | | SAME HASH MARKING AS THE COMMON WALL TO THE RESTROOMS, | | | THIS WALL DOES NOT REQUIRE THE DRYWALL TO CONTINUE TO | | | THE DECK ABOVE, WHERE AS THE STORAGE ROOM CONSIDERED A | | | INCIDENTAL USE AREA AND CONSSTRUCTION TO MEET THE | | | REQUIREMENT OF 508.2.2.1 AND CAPABLE OF RESITNG PASSAGE | | | OF SMOKE. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-05-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-05-23 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-05-23 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2012-05-23 15:00:09 | BUILDING PLAN REVIEW | | | PERMIT: 12030334 | | | ADD: 2275 PALM BEACH LAKES BLVD | | | SHILOH FAMILY WORSHIP CENTER - PHASE II | | | CONT: CUTTING EDGE BUILDING SYSTEMS, INC | | | TEL: (561)282-8265 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) NEITHER G1.0 NOR THE LS1.0 SHEET INDICATE: | | | 2A-F) COMPLIED. | | | 2G) LS1.0 NOTES INDICATES A LIMIT OF 299 OCCUPANTS, | | | PLEASE REVIEW PLANS INDICATE 302 SEATS AND AN OCCUPANT | | | LOAD WITH THE OCCUPANTS IN A/V CONTROLS & PROJECTION | | | ROOM. | | | THE OTHER ISSUE THAT WOULD STILL REQUIRE FIRE | | | SPRINKLERS WOULD BE 2007 FBC-B 903.2.1.3 EXCEPTION # 2, | | | CAN'T BE PART OF A MIXED OCCUPANCY. PLEASE REVIEW | | | SECTION 508.3.1 ACCESSORY OCCUPANCIES THE AGGREGATE | | | ACCESSORY OCCUPANCIES SHALL NOT BE MORE THAN 10% OF THE | | | AREA OF THE STORY IN WHICH THEY ARE LOCATED. | | | 2H) LS1.0 PLEASE REVIEW FBC-B 907.2.1 FOR ASSEMBLY | | | AREAS WITH OCCUPANT LOADS OF 300 OR GREATER. | | | | | | 3) COMPLIED. | | | | | | 4) COMPLIED. | | | | | | 5) PROVISO: SHEET A6.0 & A6.1 INDICATES CLOUDS AS PART | | | OF A ISOLATED CEILING DESIGN WITHIN THE ASSEMBLY | | | OCCUPANCY. PLEASE PROVIDE DETAILS ON WHAT TYPE OF | | | MATERIALS THIS SYSTEM IS COMPOSED OF, HOW IT IS TO BE | | | HUNG, AND TO WHAT THE CLOUD SYSTEM IS TO BE ATTACHED? | | | ADDITIONAL INFORMATION IS REQUIRED? 106.1.2. SHOP | | | DRAWINGS WILL BE REQUIRED TO BE REVIEWED BY THE | | | DESIGNER OF RECORD BEFORE SUBMITTING THEM TO THE | | | BUILDING DEPARTMENT. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-04-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-04-03 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-04-03 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2012-04-03 13:39:53 | BUILDING PLAN REVIEW | | | PERMIT: 12030334 | | | ADD: 2275 PALM BEACH LAKES BLVD | | | SHILOH FAMILY WORSHIP CENTER - PHASE II | | | CONT: CUTTING EDGE BUILDING SYSTEMS, INC | | | TEL: (561)282-8265 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PLANS SUBMITTED ON MARCH 14/2012 ARE TO BE REVIEWED | | | UNDER THE 2007/09 FBC. PLANS SUBMITTED ON OR AFTER | | | MARCH 15TH/ 2012 ARE TO BE REVIEWED UNDER THE 2010 FBC. | | | SHEET G1.0 GOVERNING CODES INDICATE ALL CONSTRUCTION | | | WORK, ACTIVITIES & ALTERATIONS SHALL COMPLY WITH THE | | | 2007 FBC, 2010 EXISTING BUILDING CODE. CODE DESIGNS CAN | | | NOT BE MIXED BETWEEN THE EDITIONS OF CODES. | | | | | | 2) NEITHER G1.0 NOR THE LS1.0 SHEET INDICATE: | | | 2A) MINIMUM BUILDING TYPE | | | 2B) IS THIS BUILDING FIRE SPRINKLERED? NEITHER G1.0 NOR | | | LS1.0 INDICATE FIRE SPRINKLERS, FOR THIS REVIEW IT WILL | | | BE CONSIDERED NON-SPRIKLERED | | | 2C) UNDER THE 2007/ 09 EXISTING BUILDING CODE THE | | | DESIGNER WILL NEED TO PICK A COMPLIANCE METHOD. 2007/09 | | | EXIST BLDG CODE 101.5. | | | 2D) IS THIS A CHANGE IN OCCUPANCY FOR THIS SPACE? IF SO | | | CHAPTER 9 OF THE EXIST BLDG CODE WILL APPLY. 2007/09 | | | EXIST BLDG CODE 901.3.1 PARTIAL CHANGE IN OCCUPANCY, | | | SECTION 912 SHALL APPLY. | | | 2E) LS1.0 SHEET INDICATES ADJACENT TENANT SPACES ON | | | BOTH SIDES OF THIS TENANT SPACE, THE PLANS INDICATE A | | | ONE HOUR TENANT SEPERATION WALL, PLEASE REVIEW 2007/09 | | | FBC-B TABLE 508.3.3 OCCUPANCY SEPERATION FOR EITHER | | | BUSINESS OR MERCANTILE WITH THIS A3 OCCUPANCY REQUIRES | | | A 2 HOUR OCCUPANCY SEPERATION WALL. PLEASE NOTE THAT | | | THE BUSINESS OCCUPANCY THAT TIES TO THIS TENANTCY WOULD | | | ALSO REQUIRE A 2 HOUR FIRE RATED WALL WITH 1 1/2 HOUR | | | OPENING PROTECTIVES FBC-B TABLE 715.4. SEE NOTE # 5 ON | | | SHEET A1.0 FOR A 2 HOUR WALL. | | | 2F) LS1.0 SHEET DOES NOT INDICATE ANY FIRE RATED | | | CORRIDORS, PLEASE REVIEW 2007/09 FBC-B TABLE 1017.1THAT | | | REQUIRES 1 HOUR FIRE RATED CORRIDORS WITH OR WITHOUT | | | FIRE SPRINKLERS ALSO UPDATE THE DOOR SCHEDULE FOUND ON | | | SHEET A7.0. | | | 2G) LS1.0 NOTE # 2 INDICATES A LIMIT OF 299 OCCUPANTS, | | | PLEASE REVIEW PLANS INDICATE 306 SEATS AND AN OCCUPANT | | | LOAD OF 21 FOR THE STAGE WHICH TOTALS 327 OCCUPANTS, | | | WHY THE LIMITING FACTOR TO 299? THE 2007 FBC-B | | | 903.2.1.3 DOES REQUIRE FIRE SPRINKLERS FOR OCCUPANT | | | LOADS 300 OR GREATER. | | | 2H) LS1.0 PLEASE REVIEW FBC-B 907.2.1 FOR ASSEMBLY | | | AREAS WITH OCCUPANT LOADS OF 300 OR GREATER. | | | | | | 3) SHEET A1.0: | | | 3A) WALL TYPE F IS FOUND AT ALL STORAGE ROOMS WHICH IF | | | OVER 100 SQ FT WILL REQUIRE A 1 HOUR FIRE RATING TO | | | EXTEND UP TO THE UNDER SIDE OF THE ROOF DECK FBC-B | | | 508.2.2.1. | | | 3B) WALL TYPE B CORRIDOR WALLS WILL ALSO NEED TO BE | | | UPDATED TO A 1 HOUR FIRE RATED WALL PER FBC-B 708.1( | | | 4). | | | | | | 4) 2007/09 FBC-B 712.6 FIRE WALLS, FIRE BARRIERS, FIRE | | | PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY | | | OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE | | | EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY | | | HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE | | | ANY DECORATIVE CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: "FIRE | | | AND SMOKE BARRIER - PROTECT ALL OPENINGS." | | | | | | 5) SHEET A2.0 INDICATES UNDER SIDE OF CLOUDS PLEASE | | | PROVIDE DETAILS ON WHAT TYPE OF MATERIALS THIS SYSTEM | | | IS COMPOSED OF, HOW IT IS TO BE HUNG, AND TO WHAT THE | | | CLOUD SYSTEM IS TO BE ATTACHED? ADDITIONAL INFORMATION | | | IS REQUIRED? 106.1.2. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-05-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-05-08 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-05-08 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-03-20 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-03-20 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-03-19 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2012-03-20 10:07:50 | 12030334 | | | 2275 PALM BEACH LAKES BLVD. | | | SANCTUARY AND CLASSROOMS | | | GROUP A3 | | | | | | VERIFY THAT ALL NEW AND EXISTING EQUIPMENT INTENDED TO | | | INTERRUPT CURRENT AT FAULT LEVELS HAS AN INTERRUPTING | | | RATING SUFFICIENT FOR THE NOMINAL CIRCUIT VOLTAGE AND | | | CURRENT THAT IS AVAILABLE. NEC 110.9 | | | FEEDER CONDUCTORS TO NEW PANELBOARDS, OVERCURRENT | | | DEVICES AND MAIN LUGS APPEAR TO BE MISMATCHED. LOCATE | | | ALL PANEL BOARDS ON THE PLAN SHOWING ALL SAFETY | | | CLEARANCES. NEC 310.16, 110.26 | | | PROVIDE A LIGHTING DENSITY CALCULATION SHOWING | | | COMPLIANCE WITH THE FLORIDA BUILDING ENERGY CODE | | | REQUIREMENTS. FBC 13-415 ABC.5 | | | CLARIFY ON THE PLANS HOW THE LIGHTING WILL BE | | | CONTROLLED USING MOTION SENSORS OR SIMILAR TECHNIQUES. | | | SPACE CONTROL FBC 13-415 ABC.1.2; ADDITIONAL CONTROLS | | | 13-415 ABC.1.3 | | | | | | NOTE: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR | | | SECURITY, VOICE, DATA AND FIRE ALARM SYSTEMS. | | | | | | ROBERT LECKY | | | ELECTRIC PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2012-07-30 |
|
|
Cont ID |
|
| Sent By |
rferguso |
Date |
2012-07-30 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
rferguso |
Date |
2012-07-30 |
Time |
11:42 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2012-06-30 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-06-30 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-06-30 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2012-06-30 18:48:35 | 2275 PALM BEACH LAKES BOULEVARD | | | PERMIT #12030334 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENT: ENGINEERED FIRE SPRINKLER CONSTRUCTION | | | DOCUMENTS ARE REQUIRED FOR A GENERAL BUILDING PERMIT. | | | AFTER THE BUILDING PERMIT HAS BEEN ISSUED, THE | | | SUBCONTRACTORS CAN THEN SUBMIT SHOP DRAWINGS | | | (CONFORMING TO THE ENGINEERED CONSTRUCTION DOCUMENTS) | | | FOR A SUB-PERMIT. | | | | | | TO OBTAIN A GENERAL BUILDING PERMIT, BY STATE LAW AND | | | THE FLORIDA BUILDING CODE, WHEN A FIRE SPRINKLER SYSTEM | | | IS TO BE INSTALLED OR MODIFIED, PURSUANT TO FS 553.79, | | | FIRE PROTECTION DESIGN DOCUMENTS SHALL BE PREPARED BY A | | | QUALIFIED ENGINEER AND SUBMITTED TO THE AUTHORITY | | | HAVING JURISDICTION. ALL DESIGN DOCUMENTS SUBMITTED FOR | | | THIS PURPOSE SHALL PROVIDE A SCOPE OF WORK FOR THE | | | SPRINKLER CONTRACTOR AND SHALL COMPLY WITH FBPE RULES | | | OF RESPONSIBILITY CHAPTER 61G15-32. PER 61G15-32 FAC, | | | BASIC ENGINEERING REQUIREMENTS FOR PLANS SHALL INCLUDE: | | | WATER SUPPLY INFORMATION, SUPPRESSION SYSTEM TYPE, | | | HAZARD CLASSIFICATION, APPLICABLE CODES AND STANDARDS | | | WITH APPROPRIATE YEAR/EDITION, STRUCTURAL INFORMATION | | | AND STRUCTURAL OPENINGS, ALARMS, ACTIVATION CONTROLS, | | | AND INTERFACES WITH OTHER SYSTEMS. CONTRACTOR SHOP | | | DRAWINGS ARE REQUIRED TO OBTAIN A FIRE SPRINKLER | | | PERMIT. SHOP DRAWINGS SHALL CONFORM TO THE DESIGN | | | REQUIREMENTS OF THE ENGINEER OF RECORD DESIGN | | | DOCUMENTS. SHOP DRAWINGS SHALL NOT BE SEALED BY AN | | | ENGINEER. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2012-05-21 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-05-21 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-05-21 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2012-05-21 13:38:34 | 2275 PALM BEACH LAKES BOULEVARD | | | PERMIT #12030334 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SHEET LS1.0: THE KNOX-BOX SHOWN AS "LB" INCORRECTLY | | | INDICATES THE AUTHORITY HAVING JURISDICATION AS PALM | | | BEACH COUNTY FIRE RESCUE. | | | | | | SHEET A1.0: KNOX-BOX IS INCORRECTLY IDENTIFIED BY | | | CONSTRUCTION NOTE #23 (SHOULD BE #24). | | | | | | SHEET A 7.2: COULD NOT LOCATE TACTILE SIGNAGE FOR EXIT | | | DOORS. | | | | | | SHEET A7.0: DOOR #9 DOES NOT INDICATE A FIRE RESISTANCE | | | RATING. | | | | | | SHEET A7.0: SINGLE DOOR AT MAIN ENTRANCE IS INDICATED | | | AS DOOR #7; THE SCHEDULE INDICATES DOOR #7 AS A STORAGE | | | ROOM DOOR. | | | | | | SHEET A7.0: FIRE RATED DOORS ON STORAGE ROOMS NEED TO | | | BE EQUIPPED WITH DOOR CLOSERS. | | | | | | SHEET A1.0 & SHEET A6.1: STAIRS TO PLATFORM ARE NOT | | | SHOWN ON SHEET A1.0. THE RAISED PLATFORM IS INDICATED | | | AS AN ELEVATION OF 3'-6". PROVIDE STAIR GUARDS | | | RESISTING 4-INCH SPHERE AND A PERIMETER GUARDRAIL FOR | | | THE UPPER PLATFORM. | | | | | | NOTE: ENGINEERED FIRE ALARM PLANS NOT RESUBMITTED: | | | REPEAT COMMENT: PER LOCAL AHJ POLICY, DUCT SMOKE | | | DETECTORS SHALL INITIATE A GENERAL FIRE ALARM | | | CONDITION. | | | | | | REPEAT COMMENT: PROVIDE A PRE-RECORDED FIRE ALARM | | | EVACUATION MESSAGE NOTIFYING OCCUPANTS AN EMERGENCY HAS | | | BEEN REPORTED IN THE BUILDING, LOCATE THE NEAREST EXIT, | | | AND EXIT THE BUILDING IMMEDIATELY. | | | | | | REPEAT COMMENT: A CERTIFICATE OF COMPLETION AND A THIRD | | | PARTY MONITORING/VERIFICATION (UL OR ETL) CERTIFICATE | | | SHALL BE PROVIDED AT TIME OF FINAL FIRE ALARM | | | INSPECTION. | | | | | | REPEAT COMMENT: ASSEMBLY OCCUPANCIES EXCEEDING 300 | | | PERSONS WILL BE REQUIRED TO BE PROTECTED BY AN | | | AUTOMATIC FIRE SPRINKLER SYSTEM. | | | ADDITIONAL INFORMATION: SECTION 903.2.1.3 OF THE | | | FLORIDA BUILDING CODE WILL STILL REQUIRE AN AUTOMATIC | | | SPRINKLER SYSTEM BECAUSE OF THE MIXED OCCUPANCY | | | (ASSEMBLY, MERCANTILE, EDUCATION) USAGE. ALSO REFER TO | | | SECTION 12.3.5.2 AND SECTION 12.3.5.3 (FLORIDA FIRE | | | PREVENTION CODE - NFPA 101) WHEREBY AN AUTOMATIC | | | SPRINKLER SYSTEM IS REQUIRED. | | | | | | REPEAT COMMENT: ENGINEERED FIRE SPRINKLER CONSTRUCTION | | | DOCUMENTS ARE REQUIRED FOR A GENERAL BUILDING PERMIT. | | | AFTER THE BUILDING PERMIT HAS BEEN ISSUED, THE | | | SUBCONTRACTORS CAN THEN SUBMIT SHOP DRAWINGS | | | (CONFORMING TO THE ENGINEERED CONSTRUCTION DOCUMENTS) | | | FOR A SUB-PERMIT. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2012-04-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-04-03 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-04-03 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2012-04-03 15:51:57 | 2275 PALM BEACH LAKES BOULEVARD | | | PERMIT #12030334 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | UPDATE THE CODE LIST TO REFERENCE THE 2010 EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO | | | THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION | | | DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. ALL | | | DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | THE MAIN ENTRANCE DOORS SHALL BE SIZED TO ACCOMMODATE | | | 1/2 OF THE MAXIMUM OCCUPANT LOAD. | | | | | | FOR OCCUPANCIES WITH AN OCCUPANT LOAD OF 100 OR MORE | | | PERSONS, PANIC OR FIRE EXIT HARDWARE SHALL BE PROVIDED | | | ON DOORS TO RELEASE THE LOCK/LATCH. NO OTHER LOCKS OR | | | LATCHES ARE PERMITTED THAT WOULD NOT BE RELEASED BY THE | | | PANIC HARDWARE. REFER TO DOOR #3, EX1, EX4 ETC. | | | | | | EACH SMOKE OR FIRE-RATED WALL/PARTITION SHALL BE | | | PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING | | | FIRE/SMOKE BARRIER-PROTECT ALL OPENINGS. CHARACTERS | | | SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN | | | WIDTH. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 | | | FEET ON CENTER. | | | | | | SHEET A10.1 WAS NOT SUBMITTED. | | | | | | PER LOCAL AHJ POLICY, DUCT SMOKE DETECTORS SHALL | | | INITIATE A GENERAL FIRE ALARM CONDITION. | | | | | | PROVIDE A PRE-RECORDED FIRE ALARM EVACUATION MESSAGE | | | NOTIFYING OCCUPANTS AN EMERGENCY HAS BEEN REPORTED IN | | | THE BUILDING, LOCATE THE NEAREST EXIT, AND EXIT THE | | | BUILDING IMMEDIATELY. | | | | | | A CERTIFICATE OF COMPLETION AND A THIRD PARTY | | | MONITORING/VERIFICATION (UL OR ETL) CERTIFICATE SHALL | | | BE PROVIDED AT TIME OF FINAL FIRE ALARM INSPECTION. | | | | | | ASSEMBLY OCCUPANCIES EXCEEDING 300 PERSONS WILL BE | | | REQUIRED TO BE PROTECTED BY AN AUTOMATIC FIRE SPRINKLER | | | SYSTEM. | | | | | | ENGINEERED FIRE SPRINKLER CONSTRUCTION DOCUMENTS ARE | | | REQUIRED FOR A GENERAL BUILDING PERMIT. AFTER THE | | | BUILDING PERMIT HAS BEEN ISSUED, THE SUBCONTRACTORS CAN | | | THEN SUBMIT SHOP DRAWINGS (CONFORMING TO THE ENGINEERED | | | CONSTRUCTION DOCUMENTS) FOR A SUB-PERMIT. | | | | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
P |
Date |
2012-08-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-08-02 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-08-02 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2012-08-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-08-01 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-07-20 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2012-07-20 12:59:38 | IN FIRE BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-07-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-07-09 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-06-12 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2012-06-12 11:58:28 | C-25 JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-05-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-24 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-05-07 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-04-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-04-12 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-03-14 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2012-03-15 15:26:58 | C03 | | 2012-03-15 11:46:05 | C--28 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2012-08-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-08-02 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-08-02 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2012-07-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-04-03 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-04-03 |
Time |
12:34 |
Sent To |
|
|
| Notes |
| 2012-07-05 12:36:15 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2012-07-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-07-09 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-07-09 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2012-05-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-24 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-05-24 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2012-05-24 10:24:45 | PLANS DENIED | | | 1) PROVIDE A FULL SET OF MECHANICAL PLANS MISSING | | | PAGES M-2, M-3, M-4 | | | 2) REFER TO SECTION 901.1 EXISTING BUILDING CODE | | | 2007. ALL ROOF TOP UNITS NEED TO COMPLY WITH | | | 13-409.AB.3.3 SHUTOFF DAMPER CONTROLS.2007 | | | FLORIDA ENERGY CODE. | | | 3) REFER TO SECTION 607.5.1 FIRE WALLS 2007 | | | FBC (M) MISSING A FIRE DAMPER IN 4X9 DUCT ABOVE | | | WOMENS BATHROOM. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-07-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-03-21 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-03-21 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2012-03-22 11:01:12 | PLANS DENIED | | | 1) MISSING FIRE DAMPERS IN STORAGE ROOM 114 C . | | | REFER TO SECTION 607.5.1 FIRE WALLS 2007 FBC (M) | | | 2) PROVIDE INFORMATION ON THE 18X14 DUCT GOING IN THE | | | BATHROOM. | | | IF IT IS A SUPPLY WHAT RTU IS TI COMING FROM. | | | 3) REFER TO SECTION 606.2.1 SUPPLY AIR SYSTEM 2007 FBC | | | (M) | | | AND SECTION 606.4.1 SUPERVISION NEW AND EXISTING RTU. | | | 4) REFER TO SECTION 13-409.AB.3.3 SHUTOFF DAMPER | | | CONTROLS. | | | 2007 ENERGY CODE. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-05-16 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-05-16 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-05-16 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2012-05-16 10:47:20 | CIRCUIT VENT REQUIRED - SEE PLAN |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2012-04-05 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-04-05 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-04-05 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2012-04-05 11:32:12 | FBC 2007 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. THE PLUMBING CALCULATIONS ON SHEET G1.0 SHOW 8 WATER | | | CLOSETS FOR WOMEN AND 4 FOR MEN. PLEASE CLARIFY OR | | | CORRECT THE FOLLOWING: | | | 1A. SHEET A1.0 AND PLUMBING SHEETS SHOW ONLY 4 WATER | | | CLOSETS FOR WOMEN. | | | 1B. SHEET A1.0 AND PLUMBING SHEETS SHOW 1 WATER CLOSET | | | AND 3 URINALS FOR MEN. SECTION 419.2 URINALS SHALL NOT | | | BE SUBSTITUTED FOR MORE THAN 67 PERCENT OF THE REQUIRED | | | WATER CLOSETS IN ASSEMBLY AND EDUCATIONAL OCCUPANCIES. | | | 2 WATER CLOSETS AND 2 URINALS WOULD BE REQUIRED. | | | 1C. 403.7 UNISEX TOILET AND BATHING ROOMS. IN ASSEMBLY | | | AND MERCANTILE OCCUPANCIES, AN ACCESSIBLE UNISEX TOILET | | | ROOM SHALL BE PROVIDED WHERE AN AGGREGATE OF SIX OR | | | MORE MALE AND FEMALE WATER CLOSETS IS REQUIRED. | | | | | | 2. SHEET P-2 HOT WATER WILL BE REQUIRED AT THE JANITOR | | | SINK: | | | 607.1 WHERE REQUIRED. IN OCCUPIED STRUCTURES, HOT WATER | | | SHALL BE SUPPLIED TO ALL PLUMBING FIXTURES AND | | | EQUIPMENT UTILIZED FOR BATHING, WASHING, CULINARY | | | PURPOSES, CLEANSING, LAUNDRY OR BUILDING MAINTENANCE. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2012-06-13 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2012-06-13 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2012-06-13 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2012-06-13 08:00:31 | PLANNING: PASSED **** ZONING REVIEW NOT REQUIRED: | | | INTERIOR WORK ONLY AND THE VALUE OF PROPOSED WORK DOES | | | NOT EXCEED 50% OF THE IMPROVEMENT VALUE. **** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2012-04-11 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2012-04-11 |
Time |
09:35 |
Rev Time |
0.25 |
| Received By |
lfranco |
Date |
2012-04-11 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2012-04-11 09:35:41 | PLANNING: PASSED **** ZONING REVIEW NOT REQUIRED: | | | INTERIOR WORK ONLY AND THE VALUE OF PROPOSED WORK DOES | | | NOT EXCEED 50% OF THE IMPROVEMENT VALUE. **** |
|
|