Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-03-15 Cont ID  
Sent By jgomez Date 2012-03-15 Time 11:44 Rev Time 0.00
Received By jgomez Date 2012-03-15 Time 11:44 Sent To  
Notes
2012-03-15 11:46:59REVISED ASSEMBLY APPROVED AFTER ROBERT BROWN (AND
 JULIO) PHONE CONVERSATION WITH ANDY SMALL FROM LIFETIME
 ROOF & CONSTRUCTION INC, TO CLARIFY PROPOSED
 INSTALLATION.
  
 THE REVISED INSTALLATION IS FOR THE NORTHERN SLOPE OF
 4:12 PITCHED ROOF. THE PROPOSED INSTALLATION AS
 DESCRIBED IN THE REVISION FORM IS AS FOLLOWS:
 "INSTALL 30# ASTM D226 FASTENED TO T/G 3 1/4" ROOF DECK
 USING 1.25" NAILS & TAGS - INSTALL 4'X4'X2" ISO OVER
 30# USING 3" SCREWS & 3" PLATES - INSTALL 30# ASTM D
 226 OVER ISO USING 3" SCREWS & 3" PLATES - INSTALL CTD
 FLINTLASTIC GMS OVER 30# FULLY MOPPED AT A RATE OF
 25LBS/SF." THEN THE CONCRETE TILE IS INSTALLED USING

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-03-12 Cont ID  
Sent By rbrown Date 2012-03-12 Time 19:02 Rev Time 0.00
Received By rbrown Date 2012-03-12 Time 19:02 Sent To  
Notes
2012-03-12 19:16:27REVSIED PRODUCT APPROVALS FOR UNDERLAYMENT AND
 INSULATION.
  
  
 PLEASE SUBMIT ADDITIONAL INFORMATION:
  
 COMPATIBILITY OF PRODUCTS - NEITHER NOTICE OF
 ACCEPTANCE (NOA) LISTS THE OTHER OTHER MANUFACTURER'S
 PRODUCT AS A COMPONENT PART OF AN ASSEMBLY. PER
 LIMITATION 8 ON PAGE 6 OF CERTAINTEED CORPORATION NOA#
 10-0608.01, AND LIMITATION 2 ON PAGE 3 OF GENFLEX
 ROOFING SYSTEMS NOA# 08-1117.01, ADDITIONAL
 DOCUMENTATION IS REQUIRED TO DEMONSTRATE COMPATIBILITY
 OF THE UNDERLAYMENT AND INSULATION BOARD. SUCH
 DOCUMENTATION MAY BE IN THE FORM OF A LETTER FROM THE
 MANUFACTURER, OR AUTHORIZED REPRESENTATIVE, OF EACH
 PRODUCT STATING THAT THEY HAVE NO OBJECTION TO THE USE
 OF THEIR PRODUCT WITH THE OTHER MANUFACTURER'S PRODUCT.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 TELEPHONE: (561) 805 6652 ROBERT BROWN
 E-MAIL: [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-03-15 Cont ID  
Sent By jgomez Date 2012-03-15 Time 11:44 Rev Time 0.00
Received By jgomez Date 2012-03-15 Time 11:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-03-12 Cont ID  
Sent By rbrown Date 2012-03-12 Time 19:01 Rev Time 0.00
Received By rbrown Date 2012-03-12 Time 19:01 Sent To  
Notes
2012-03-12 19:01:52REVISED PRODUCT APPROVALS SENT TO ROBERT BROWN FOR