Plan Review Details - Permit 12030123
Plan Review Stops For Permit 12030123
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-04-25 Cont ID  
Sent By jwitmer Date 2012-04-25 Time 15:53 Rev Time 0.00
Received By jwitmer Date 2012-04-25 Time 15:53 Sent To  
Notes
2012-04-25 16:06:19BUILDING PLAN REVIEW
 PERMIT: 12030123
 ADD: 401 S DIXIE HWY
 CONT: TBD
 TEL: (561)366-8286
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) A REVISION FOR THE SOUTH STAIRWAY REMOVING THE
 RESTROOMS FROM WITHIN THE RATED STAIRWELL & WILL BE
 SUBMITTED TO BE INCLUDED IN THE NORTH LOBBY PERMIT.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-04-18 Cont ID  
Sent By jwitmer Date 2012-04-18 Time 13:09 Rev Time 0.00
Received By jwitmer Date 2012-04-17 Time 16:00 Sent To  
Notes
2012-04-18 13:06:35BUILDING PLAN REVIEW
 PERMIT: 12030123
 ADD: 401 S DIXIE HWY
 CONT: TBD
 TEL: (561)366-8286
  
 2010 FLORIDA BUILDING CODE W/
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING. [B] 302.1
 EXISTING BUILDINGS OR STRUCTURES. ADDITIONS OR
 ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY
 WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE,
 BUILDING FOR NEW CONSTRUCTION. ADDITIONS OR ALTERATIONS
 SHALL NOT BE MADE TO AN EXISTING BUILDING OR STRUCTURE
 THAT WILL CAUSE THE EXISTING BUILDING OR STRUCTURE TO
 BE IN VIOLATION OF ANY PROVISIONS OF THE FLORIDA
 BUILDING CODE, BUILDING
  
 2ND REVIEW
 ACTION: DENIED
  
 NOTE: SHEET A-1.0 INDICATES AN EXISTING VERTICAL EXIT
 STAIR THAT LEADS INTO A LOBBY, NOT TO A EXIT PASSAGE
 WAY OR EXIT DISCHARGE. PLEASE REVIEW THE COVERSHEET
 CS-1 THE KEY MAP THAT SHOWS AN EXIT PASSAGEWAY TO THE
 EXIT DISCHARGE. 2007/09 EXISTING BUILDING CODE [B]
 302.1 EXISTING BUILDINGS OR STRUCTURES. ADDITIONS OR
 ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY
 WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE,
 BUILDING FOR NEW CONSTRUCTION. ADDITIONS OR ALTERATIONS
 SHALL NOT BE MADE TO AN EXISTING BUILDING OR STRUCTURE
 THAT WILL CAUSE THE EXISTING BUILDING OR STRUCTURE TO
 BE IN VIOLATION OF ANY PROVISIONS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1) COMPLIED.
  
 2)SHEET A-1.0 INDICATES THE INSTALATION OF NEW EXTERIOR
 BI-PARTING DOORS AND OR NEW BI-PATING DOORS WITH SIDE
 LIGHTS AND NEW WINDOWS.
 FBC-B 1609 COMPONENTS & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS. BI-PARTING DOORS.
 (B) WINDOWS -HIGHLIGHT TYPE OF GLAZING TO BE INSTALLED,
 MULLION REPORT INCLUDED IN WINDOW NOA LENGHT IS GOOD
 FOR ONLY 120 INCHES OR 10 FT. PLANS INDICATE THE
 HORIZONTAL MULLION WILL NEED TO SPAN 15'-5".
 C) MULLIONS
  
 3) NEW COMMENT: MISSING WIND DESIGN, PLANS SUBMITTED
 AFTER MARCH 14/ 2012 ARE TO BE DESIGNED TO THE 2010
 FBC-B AND ASCE 7-10 PLEASE PROVIDE WIND ZONE AAND
 ASSOCIATED PRESSURES V (ULT). FBC-B 1609.
  
 4) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 5) COMPLIED.
  
 6) SHEET A-2.0 DETAIL DOOR TYPE B3 THE BIPARTING DOORS
 AND TRANSOM ABOVE, WHAT TYPE OF STRUCTURAL MEMBER WILL
 BE LOCATED BETWEEN THE BI-PARTING DOORS AND TRANSOM
 WINDOWS ABOVE? HOW WILL IT BE ANCHORED INTO THE MAIN
 WIND FORCE RESISTING SYSTEM? PROVIDE ADDITIONAL PRODUCT
 APPROVAL FOR MULLION OR FRAMING, BEAM SUPPORT.
  
 7) COMPLIED.
  
 8) SHEET S-2 GLASS & ALUMINUM FRAME CANOPY DESIGGN,
 FABRICATION AND ASSEMBLY SHALL CONFORM TO AAASM 35 AND
 SPECIFICATIONS FOR ALUMINUM STRUCTURES.
  
 9) SHEET S-2GLAZING IN SLOPED ASSEMBLIES SHALL COMPLY
 WITH FBC-B 2405.2 ALLOWABLE GLAZING MATERIALS AND
 LIMITATIONS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-03-14 Cont ID  
Sent By jwitmer Date 2012-03-14 Time 14:02 Rev Time 0.00
Received By jwitmer Date 2012-03-14 Time 13:31 Sent To  
Notes
2012-03-14 14:13:57BUILDING PLAN REVIEW
 PERMIT: 12030123
 ADD: 401 S DIXIE HWY
 CONT: TBD
 TEL: (561)366-8286
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 NOTE: SHEET A-1.0 INDICATES AN EXISTING VERTICAL EXIT
 STAIR THAT LEADS INTO A LOBBY, NOT TO A EXIT PASSAGE
 WAY OR EXIT DISCHARGE. UNDER THE 2007/09 EXISTING
 BUILDING CODE SECTION
 703.2.3 THE WORK AREA WOULD NEED TO EXCEED 50% OF THAT
 FLOOR AREA TO ENACT THIS SECTION. THAT THE 50% LIMIT
 HAS NOT BEEN REACHED, THIS IS ONLY A NOTICE OF A
 PRE-EXISTING NON-CODE COMPLIANT AREA OF THE BUILDING.
  
 1) THE NEW TENANT WALL THAT SEPERATES THE LOBBY FROM
 THE NEW TENANTCY, PLEASE PROVIDE COMPLIANCE WITH
 SECTION FBC-B 708.1 TENANT SEPERATION WALLS REQUIRING 1
 HOUR SERARATION FOR THE GLASS WALL SECTION AND OPENING
 PROTECTION FOR GLAZED DOORS PER FBC-B T 715.4.
  
 2)SHEET A-1.0 INDICATES THE INSTALATION OF NEW EXTERIOR
 BI-PARTING DOORS AND OR NEW BI-PATING DOORS WITH SIDE
 LIGHTS AND NEW WINDOWS.
 FBC-B 1609 COMPONENTS & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS. BI-PARTING DOORS.
 (B) WINDOWS
 C) MULLIONS
  
 4) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 5) PLEASE PROVIDE DOCUMENTATION FOR CODE COMPLIANCE FOR
 THE EXTERIOR BI-PARTING EXTERIOR DOORS FBC-B
 1008.1.3.2. WITH LOSS OF POWER HOW WILL THESE DOORS
 STILL FUNCTION AS PART OF THE MEANS OF EGRESS.
  
 6) SHEET A-2.0 DETAIL DOOR TYPE B3 THE BIPARTING DOORS
 AND TRANSOM ABOVE, WHAT TYPE OF STRUCTURAL MEMBER WILL
 BE LOCATED BETWEEN THE BI-PARTING DOORS AND TRANSOM
 WINDOWS ABOVE? HOW WILL IT BE ANCHORED INTO THE MAIN
 WIND FORCE RESISTING SYSTEM?
  
 7) SHEET A-1.0 THE NEW MAILBOX ROOM PLEASE SHOW
 COMPLIANCE FOR THE WHEELCHAIR TURNING SPACE PER FBC-B
 11-4.2.3 & FIGURE 3.
  
 8) SHEET S-2 GLASS & ALUMINUM FRAME CANOPY DESIGGN,
 FABRICATION AND ASSEMBLY SHALL CONFORM TO AAASM 35 AND
 SPECIFICATIONS FOR ALUMINUM STRUCTURES.
  
 9) SHEET S-2GLAZING IN SLOPED ASSEMBLIES SHALL COMPLY
 WITH FBC-B 2405.2 ALLOWABLE GLAZING MATERIALS AND
 LIMITATIONS.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-04-25 Cont ID  
Sent By rlecky Date 2012-04-25 Time 16:12 Rev Time 0.00
Received By rlecky Date 2012-04-25 Time 16:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-03-09 Cont ID  
Sent By rlecky Date 2012-03-09 Time 16:48 Rev Time 0.00
Received By rlecky Date 2012-03-09 Time 16:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2012-04-25 Cont ID  
Sent By wjolin Date 2012-04-25 Time 10:34 Rev Time 0.00
Received By wjolin Date 2012-04-25 Time 10:23 Sent To  
Notes
2012-04-25 10:34:00401 SOUTH DIXIE HIGHWAY
 PERMIT #12030123
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 *****PROVISO*****
  
 THE SOUTH STAIR EXIT DISCHARGE WILL NEED TO BE
 RENOVATED TO MEET THE REQUIREMENTS OF AN EXIT
 PASSAGEWAY. THIS MODIFICATION WILL BE REQUIRED BEFORE
 ANY FINAL FIRE INSPECTION/OCCUPANCY IS PERMITTED. PER
 EMAIL CORRESPONDENCE DATED 04/23/12, A REVISION TO THE
 LOBBY WORK WILL BE SUBMITTED BY THE ARCHITECT TO
 CORRECT THE DEFICIENCIES OF THE SOUTH STAIR EXIT.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2012-04-17 Cont ID  
Sent By wjolin Date 2012-04-17 Time 12:13 Rev Time 0.00
Received By wjolin Date 2012-04-17 Time 11:43 Sent To  
Notes
2012-04-17 12:13:01401 SOUTH DIXIE HIGHWAY
 PERMIT #12030123
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 NEW: RECOMMEND PROVIDING A LIFE SAFETY PLAN SHOWING ALL
 EXITS, FIRE RATED WALLS, TENANT SEPARATION WALLS, EXIT
 SIGNS, EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON
 PATH OF TRAVEL, OCCUPANCY TYPES ETC.
  
 REPEAT COMMENT: TRASH AND CONSTRUCTION DEBRIS SHALL BE
 REMOVED FROM THE SITE DAILY. SMOKING SHALL BE
 PROHIBITED EXCEPT IN DESIGNATED AREAS. ALL OTHER
 DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO
 SMOKING" SIGNS POSTED.
  
 REPEAT COMMENT: WHERE SMOKING IS PERMITTED, SAFE
 RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED.
  
 REPEAT COMMENT: FIRE PROTECTION SYSTEMS SHALL REMAIN
 ACTIVE DURING DEMOLITION AND RENOVATION ACTIVITIES. IN
 THE EVENT A FIRE PROTECTION SYSTEM IS OUT OF SERVICE
 FOR MORE THAN 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING
 SHALL BE PLACED UNDER A FIRE WATCH. ALL FIRE WATCH
 REQUESTS MUST BE SUBMITTED IN WRITING AND APPROVED BY
 THE OFFICE OF THE FIRE MARSHAL LOCATED AT 500 NORTH
 DIXIE HIGHWAY.
  
 REPEAT COMMENT: PROVIDE AN EXTERIOR KEY SAFE TO ALLOW
 EMERGENCY RESPONDERS NON-FORCIBLE ENTRY INTO THE
 BUILDING DURING NON-BUSINESS HOURS. A KEY SAFE CAN BE
 ORDERED FROM WWW.KNOXBOX.COM.
  
 REPEAT COMMENT: PROVIDE PORTABLE FIRE EXTINGUISHERS.
 EXTINGUISHERS SHALL HAVE A MINIMUM RATING OF 2A:10BC
 AND SHALL BE TAGGED BY A LICENSED FIRE EXTINGUISHER
 COMPANY. TRAVEL DISTANCE TO EXTINGUISHERS SHALL NOT
 EXCEED 75 FEET.
  
 REPEAT COMMENT: PROVIDE TACTILE SIGNAGE AT ALL REQUIRED
 EXIT DOORS WITH EXIT SIGNS.
  
 REPEAT COMMENT: NO ELECTRICAL OR MECHANICAL PLANS
 SUBMITTED.
  
 SHEET A-1.0:
 REPEAT COMMENT: THE DEMOLITION PLAN SHOWS THE EXIT
 PASSAGEWAY BEING REMOVED FROM THE NORTH STAIR. THIS
 REMOVAL WILL RESULT IN OCCUPANTS HAVING TO LEAVE THE
 FIRE RATED STAIR ENCLOSURE AND EGRESS THROUGH THE
 LOBBY.
  
 NEW: THE RESPONSE LETTER DATED MARCH 29, 2012 INDICATES
 THE SOUTH STAIR EXITS DIRECTLY TO THE EXTERIOR OF THE
 BUILDING; HOWEVER, THE OVERALL FLOOR PLAN LOCATED ON
 SHEET A-1.0 INDICATES INTERIOR STAIR DISCHARGE.
  
 REPEAT COMMENT:SMOKE OR FIRE-RATED WALLS SHALL BE
 PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING
 FIRE/SMOKE BARRIER-PROTECT ALL OPENINGS. CHARACTERS
 SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN
 WIDTH. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15
 FEET ON CENTER.
  
 REPEAT COMMENT: PROVIDE SMOKE DETECTION FOR ELEVATOR
 LOBBY RECALL OPERATIONS.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-03-09 Cont ID  
Sent By wjolin Date 2012-03-09 Time 14:48 Rev Time 0.00
Received By wjolin Date 2012-03-09 Time 13:31 Sent To  
Notes
2012-03-09 14:47:58401 SOUTH DIXIE HIGHWAY
 PERMIT #12030123
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 UPDATE THE CODE LIST TO REFERENCE THE 2010 EDITION OF
 THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE
 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA
 AMENDMENTS.
  
 ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO
 THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION
 DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. SMOKING
 SHALL BE PROHIBITED EXCEPT IN DESIGNATED AREAS. ALL
 OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO
 SMOKING" SIGNS POSTED.
  
 WHERE SMOKING IS PERMITTED, SAFE RECEPTACLES FOR
 SMOKING MATERIALS SHALL BE PROVIDED.
  
 FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF
 THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.
  
 PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY
 RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING
 NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM
 WWW.KNOXBOX.COM.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 MODIFICATION OF THE FIRE SPRINKLER SYSTEM AND FIRE
 ALARM SYSTEM.
  
 PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 NO ELECTRICAL OR MECHANICAL PLANS SUBMITTED.
  
 SHEET A-1.0:
 THE DEMOLITION PLAN SHOWS THE EXIT PASSAGEWAY BEING
 REMOVED FROM THE NORTH STAIR. THIS REMOVAL WILL RESULT
 IN OCCUPANTS HAVING TO LEAVE THE FIRE RATED STAIR
 ENCLOSURE AND EGRESS THROUGH THE LOBBY.
  
 SMOKE OR FIRE-RATED WALLS SHALL BE PERMANENTLY
 IDENTIFIED WITH SIGNS OR STENCILING READING FIRE/SMOKE
 BARRIER-PROTECT ALL OPENINGS. CHARACTERS SHALL BE AT
 LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN WIDTH.
 IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 FEET ON
 CENTER.
  
 THE 1-HOUR TENANT DEMISING PARTITION INDICATES AN
 ALUMINUM DOOR WITH GLAZING AND FOUR GLAZED WALL
 SECTIONS. NONE OF THE GLAZING IS INDICATED AS
 FIRE-RATED GLASS.
  
 PROVIDE SMOKE DETECTION FOR ELEVATOR LOBBY RECALL
 OPERATIONS.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2012-05-14 Cont ID  
Sent By lmartine Date 2012-04-26 Time 16:03 Rev Time 0.00
Received By lmartine Date 2012-04-23 Time 10:36 Sent To  
Notes
2012-04-24 10:36:43SENT TO B11 FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-05-14 Cont ID  
Sent By lmartine Date 2012-04-25 Time 16:02 Rev Time 0.00
Received By lmartine Date 2012-04-20 Time 16:44 Sent To  
Notes
2012-04-20 16:44:54TO FIRE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-04-19 Cont ID  
Sent By lmartine Date 2012-04-18 Time 16:42 Rev Time 0.00
Received By lmartine Date 2012-04-03 Time 11:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-03-16 Cont ID  
Sent By shill Date 2012-03-16 Time 09:46 Rev Time 0.00
Received By shill Date 2012-03-07 Time 10:59 Sent To  
Notes
2012-03-15 15:40:363/15/12. TO LM

Review Stop Z ZONING
Rev No 2 Status P Date 2012-04-11 Cont ID  
Sent By aaponte Date 2012-04-11 Time 09:35 Rev Time 0.00
Received By aaponte Date 2012-04-11 Time 09:35 Sent To  
Notes
2012-04-11 09:36:14CANOPY REMOVED FROM THE SCOPE OF WORK. (STAFF SPOKE
 WITH KENT WILMERING ON 4-11-12)
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.

Review Stop Z ZONING
Rev No 1 Status F Date 2012-03-15 Cont ID  
Sent By aaponte Date 2012-03-15 Time 15:35 Rev Time 0.00
Received By aaponte Date 2012-03-15 Time 15:35 Sent To  
Notes
2012-03-15 15:39:251. PROPOSED CANOPY SHALL PROJECT A MINIMUM OF 8 FEET
 FROM THE BUILDING FACADE.
 2. PLEASE INDICATE THE CANOPY VERTICAL CLEARANCE FROM
 SIDEWALK. MINIMUM 10 FEET VERTICAL CLEARANCE SHALL BE
 PROVIDED.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.