Plan Review Details - Permit 12030118
Plan Review Stops For Permit 12030118
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-03-12 Cont ID  
Sent By shill Date 2012-03-12 Time 08:26 Rev Time 0.00
Received By shill Date 2012-03-12 Time 08:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2012-03-26 Cont ID  
Sent By rlecky Date 2012-03-26 Time 12:04 Rev Time 0.00
Received By rlecky Date 2012-03-26 Time 12:04 Sent To  
Notes
2012-03-26 12:05:33NO CHANGE, SEE STAMPED ELECTRIC PLANS FROM 1ST REVIEW.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-03-12 Cont ID  
Sent By rlecky Date 2012-03-12 Time 11:27 Rev Time 0.00
Received By rlecky Date 2012-03-12 Time 10:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2012-04-04 Cont ID  
Sent By wjolin Date 2012-04-04 Time 11:10 Rev Time 0.00
Received By wjolin Date 2012-04-04 Time 11:02 Sent To  
Notes
2012-04-04 11:10:39301 CLEMATIS STREET - SUITE #107
 PERMIT #12030118
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 ALL FIRE PLAN REVIEW COMMENTS HAVE BEEN ADDRESSED.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-03-08 Cont ID  
Sent By wjolin Date 2012-03-08 Time 12:40 Rev Time 0.00
Received By wjolin Date 2012-03-08 Time 09:58 Sent To  
Notes
2012-03-08 12:40:01301 CLEMATIS STREET - SUITE #107
 PERMIT #12030118
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 UPDATE THE CODE LIST TO REFERENCE THE 2010 EDITION OF
 THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE
 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA
 AMENDMENTS.
  
 ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO
 THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION
 DEBRIS SHALL BE REMOVED FROM THE SITE DAILY.
  
 FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF
 THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.
  
 PORTABLE FIRE EXTINGUISHERS SHALL HAVE A MINIMUM RATING
 OF 2A:10BC AND SHALL BE TAGGED BY A LICENSED FIRE
 EXTINGUISHER COMPANY.
  
 A MAXIMUM OCCUPANT LOAD SIGN OF 49 PERSONS NEEDED TO BE
 CONSPICUOUSLY POSTED IN THE CUSTOMER SEATING AREA. THE
 MAXIMUM OCCUPANT LOAD INCLUDES INDOOR SEATING AND ANY
 FUTURE OUTSIDE SEATING.
  
 PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY
 RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING
 NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM
 WWW.KNOXBOX.COM.
  
 PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 FIRE-RATED WALLS SHALL BE PERMANENTLY IDENTIFIED WITH
 SIGNS OR STENCILING READING FIRE/SMOKE BARRIER-PROTECT
 ALL OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN
 HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE
 SPACED NOT MORE THAN 15 FEET ON CENTER.
  
 PENETRATIONS THROUGH A FIRE-RATED WALL ASSEMBLY SHALL
 BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE.
  
 INDICATE LOCATIONS OF EXISTING FIRE ALARM NOTIFICATION
 APPLIANCES.
  
 NO FIRE SPRINKLER PROTECTION IS SHOWN IN THE WATER
 HEATER CLOSET OR SPRINKLER RISER ROOM.
  
 AN ADDITIONAL SPRINKLER IS NEEDED IN THE DRY STORAGE
 AREA TO ACCOUNT THE FOR THE COLUMN OBSTRUCTION.
  
 THE LOCATION OF THE NEW WALLS IN THE STAFF PREP AREA
 MAY RESULT IN RELOCATED SPRINKLERS TO PROVIDE PROPER
 COVERAGE.
  
 IF NOT ALREADY EXISTING, PROVIDE THE FOLLOWING:
 1) CHAIN WITH LOCK FOR SUPERVISING THE BACKFLOW
 PREVENTER IN THE OPEN POSITION.
 2) LOCKING KNOX CAPS ON FIRE DEPARTMENT CONNECTION.
 3) REFLECTIVE, WEATHERPROOF SIGN MARKING THE FIRE
 DEPARTMENT CONNECTION LOCATION.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-04-06 Cont ID  
Sent By lmartine Date 2012-04-06 Time 17:19 Rev Time 0.00
Received By lmartine Date 2012-03-23 Time 14:05 Sent To  
Notes
2012-03-23 14:07:15B06

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-03-14 Cont ID  
Sent By hmoser Date 2012-03-14 Time 10:14 Rev Time 0.00
Received By hmoser Date 2012-03-06 Time 11:23 Sent To  
Notes
2012-03-07 11:24:22EXPEDITED
 B--6

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-04-05 Cont ID  
Sent By hmoser Date 2012-04-05 Time 13:31 Rev Time 0.00
Received By hmoser Date 2012-04-05 Time 13:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-03-14 Cont ID  
Sent By hmoser Date 2012-03-14 Time 10:13 Rev Time 0.00
Received By hmoser Date 2012-03-13 Time 14:16 Sent To  
Notes
2012-03-14 10:13:49PLANS DENIED
 1) EQUIPMENT SUBMITTAL SUBMITTED WITH THE PLANS DO NOT
 MATCH
 EQUIPMENT SCHEDULE ON THE PLANS .SECTION 106.3 2007 FBC
 2) REFER TO SECTION 13-409.AB.3.3 SHUTOFF DAMPER
 CONTROLS
 FOR FRESH AIR 2007 ENERGY CODE.
 3) CONDENSER UNIT DETAIL ON PAGE AC-1 DOES NOT SHOW THE
 SIZE BOLT USED FOR THE TIE DOWN.301.12 WIND RESISTANCE
 2007 FBC (M)
 4) PROVIDE A DETAIL ON THE PLANS SHOWING EQUIPMENT RACK
 TIE DOWN TO ROOF SECTION 301.12 WIND RESISTANCE 2007
 FBC (M)
 5) REFER TO SECTION 606.2.1 SUPPLY AIR SYSTEMS AND
 606.4.1
 SUPERVISION 2007 FBC (M)
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-04-03 Cont ID  
Sent By lwagner Date 2012-04-03 Time 10:48 Rev Time 0.00
Received By lwagner Date 2012-04-03 Time 09:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-03-13 Cont ID  
Sent By lwagner Date 2012-03-13 Time 12:29 Rev Time 0.00
Received By lwagner Date 2012-03-13 Time 09:09 Sent To  
Notes
2012-03-13 12:28:57FBC PLUMBING 2007 REVIEW #1
 DENIED:
  
 1. THE YOGURT MAKERS WILL BE REQUIRED TO BE CONNECTED
 TO AN INTERCEPTOR AND THE FIXTURES IN THE STAFF SALES
 AREA MAY NEED TO BE CONNECTED, DEPENDING UPON WHAT IS
 BEING DRAINED.
 1003.1 WHERE REQUIRED. INTERCEPTORS AND SEPARATORS
 SHALL BE PROVIDED TO PREVENT THE DISCHARGE OF OIL,
 GREASE, SAND AND OTHER SUBSTANCES HARMFUL OR HAZARDOUS
 TO THE BUILDING DRAINAGE SYSTEM, THE PUBLIC SEWER, THE
 PRIVATE SEWAGE DISPOSAL SYSTEM OR THE SEWAGE TREATMENT
 PLANT OR PROCESSES.
 1003.3.4.1 GREASE INTERCEPTOR CAPACITY. GREASE
 INTERCEPTORS SHALL HAVE THE GREASE RETENTION CAPACITY
 INDICATED IN TABLE 1003.3.4.1 FOR THE FLOW-THROUGH
 RATES INDICATED.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 1 Status N Date 2012-04-06 Cont ID  
Sent By aaponte Date 2012-04-06 Time 09:44 Rev Time 0.00
Received By aaponte Date 2012-04-06 Time 09:44 Sent To  
Notes
2012-04-06 09:45:08INTERIOR ONLY