| Plan Review Stops For Permit 12030104 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-06-13 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-06-13 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2012-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-03-14 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-03-14 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2012-03-14 08:57:27 | BUILDING PLAN REVIEW | | | PERMIT: 12030104 | | | ADD: 375 S ROSEMARY AVE | | | CONT: OAK CONSTRUCTION | | | TEL: (954)583-9625 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: | | | | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | PLEASE PROVIDE BY FIRST BUILDING INSPECTION; | | | | | | 1) SHEET S-2 DETAILS 1 & 2 BOTH INDICATE THE USE OF | | | STEEL TIE DOWN STRAPS, NO MANUFACTURER NOR PRODUCT | | | MODEL NUMBER IS PROVIDED. THE PLANS INDICATE IN BOTH OF | | | THESE DETAILS TRIPLE THICK ENDS, DETAIL # 2 INDICATES | | | TO FOLD THE ENDS. PLEASE PROVIDE APPROVAL FROM THE | | | MANUFACTURER FOR USE OF THERE PRODUCT IN THIS MANNER. | | | SIMPSON IN THEIR LITERATURE | | | HAS TWO AREAS WHERE THEY SPECIFICALLY WARN AGAINST THIS | | | PRACTICE. IN SMPSONS 2011-2012 CATALOG PAGE 21 UNDER | | | THE IMPORTANT INFORMATION & GENERAL NOTES: | | | 1) WARNING # 4 ONLY BEND PRODUCTS THAT ARE SPECIFICALLY | | | DESIGNED TO BE BENT. | | | 2) HEADING GENERAL NOTES (I) UNLESS OTHERWISE NOTED, | | | BENDING STEEL IN THE FIELD MAY CAUSE FRACTURES AT THE | | | BEND LINE. FRACTURED STEEL WILL NOT CARRY LOAD AND MUST | | | BE REPLACED. | | | | | | 2) SHEET S-2 DETAIL # 2 IT IS NOT CLEAR IF THE STRAP IS | | | A SINGLE STRAP THAT BOLTS INTO THE BENCH BEAM IS A | | | CONTINUAL STRAP UP OVER THE A/C COMPRESSOR AND THE | | | OTHER END ATTACHING TO THE OPPOSITE SIDE OF THE BENCH | | | BEAM? OR ARE THE FASTENERS TO THE CONDENSING UNIT | | | MISSING THE FASTENER TYPE? | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-03-12 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-03-12 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-03-12 |
Time |
12:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2012-06-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-06-14 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-06-14 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2012-04-02 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-04-02 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-04-02 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2012-04-02 11:28:40 | 375 SOUTH ROSEMARY AVENUE | | | PERMIT #12030104 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | DRAWINGS WILL BE STAMPED, INITIALED, AND DATED BY THE | | | FIRE DEPARTMENT AFTER ALL CITY PLAN REVIEWER COMMENTS | | | HAVE BEEN SATISFIED. | | | | | | POST WEATHERPROOF NO SMOKING SIGNS NEAR NEW LP TANK. | | | | | | PROVIDE SEPARATE PLANS AND PERMITS FOR FIRE SPRINKLER, | | | FIRE ALARM AND HOOD SUPPRESSION MODIFICATIONS. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-06-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-06-26 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-05-29 |
Time |
18:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-04-02 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-04-02 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-03-06 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-06-07 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-06-07 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-06-07 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-03-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-03-23 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-03-22 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2012-03-23 09:00:38 | PLANS DENIED | | | 1) PROVIDE A DETAIL FROM THE ENGINEER ON THE CURB | | | ADAPTER TO CURB TIE DOWN | | | AND UNIT TO CURB TIE DOWN PER SECTION 301.21 WIND | | | RESISTANCE 2007 FBC (M) | | | 2) REFER TO SECTION 304.10 GUARDS 2007 FBC (M) | | | 3) SEPARATE APPLICATION, PLANS AND PERMIT REQUIRED FOR | | | REFRIGERATION & COOLERS. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-06-19 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-06-19 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-06-19 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2012-06-19 09:42:46 | EXISTING HEATER RELIEF & PAN DRAIN OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-03-09 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-03-09 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-03-07 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2012-03-09 13:20:55 | ****PROVISO**** | | | | | | WATER HEATER RELIEF SHALL: | | | 2.DISCHARGE THROUGH AN AIR GAP LOCATED | | | IN THE SAME ROOM AS THE WATER HEATER. | | | 4. SERVE A SINGLE RELIEF DEVICE AND SHALL | | | NOT CONNECT TO PIPING SERVING ANY OTHER | | | RELIEF DEVICE OR EQUIPMENT. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2012-06-06 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2012-06-06 |
Time |
09:47 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2012-06-06 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2012-03-13 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2012-03-13 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2012-03-13 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2012-03-13 12:07:11 | FAILED | | | | | | PLEASE RESPOND IN WRITING. | | | | | | 1) PLEASE VERIFY THAT NO CHANGES ARE BEING MADE THE | | | EXTERIOR FACADE OF THE BUILDING. | | | | | | 2) THE PLANS SHOW THE INSTALLATION OF NEW ROOF MOUNTED | | | EQUIPMENT. THE CITYPLACE DRI REQUIRES THAT ALL ROOFTOP | | | MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO SUCH | | | ITEMS AS PUBLIC AND PRIVATE UTILITY SERVICE | | | CONNECTIONS; HEATING, VENTILATING, AND AIR CONDITIONING | | | SYSTEMS; COMMUNICATIONS DEVICES; AND RELATED EQUIPMENT, | | | SHALL BE SCREENED FROM PUBLIC VIEW. PLEASE PROVIDE | | | DETAILS ON HOW THE NEW ROOFTOP EQUIPMENT WILL BE | | | SCREENED. THE HEIGHT OF THE EQUIPMENT AND THE HEIGHT OF | | | THE SCREENING SHALL BE PROVIDED. | | | | | | 3) THE PLANS SHOW A 120 GALLON LP TANK ON THE NORTH | | | SIDE OF THE BUILDING ADJACENT TO THE ALLEY. IS THIS | | | TANK PROPOSED TO BE ABOVE OR BELOW GRADE? IF ABOVE | | | GRADE THEN IT SHALL BE SCREENED FROM PUBLIC VIEW IN | | | ACCORDANCE WITH THE CITYPLACE DRI REQUIREMENTS. THE | | | SITE PLAN SHOWS LANDSCAPE AT THIS LOCATION THAT WOULD | | | HAVE TO BE REMOVED FOR THE INSTALLATION OF A TANK. | | | PLEASE CLARIFY. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|