Plan Review Details - Permit 12030094
| Plan Review Stops For Permit 12030094 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-29 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-29 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2012-03-29 16:54:17 | PRODUCT APPROVALS FOR EXTERIOR DOORS WERE SUBMITTED BY | | | MISTAKE. NO EXTERIOR DOORS ARE BEING REPLACED PER | | | CONTRACTOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-19 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-14 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2012-03-19 13:52:21 | 2007 FBC W/2009 REVISIONS | | | | | | 1) THE PRODUCT APPROVAL FOR THE EXTERIOR GLAZED DOOR | | | HAS DESIGN PRESSURES OF + 48 , -51 PSF AND THE PLANS | | | SPECIFY THE REQUIRED PRESSURES FOR A 10 SQFT OPENING OF | | | +56, -55 PSF. PLEASE SUBMIT PRODUCT APPROVALS FOR A | | | DOOR WITH DESIGN PRESSURES GREATER THAN THE ONES | | | SPECIFIED ON THE PLANS. FBC R301.2.1 | | | | | | 2) THE GLAZED EXTERIOR DOOR IS REQUIRED BY FBCR | | | 301.2.1.2 AND EXISTING BUILDING 606.4 TO HAVE OPENING | | | PROTECTION FROM WIND BORNE DEBRIS. THE PRODUCT APPROVAL | | | THAT WAS SUBMITTED IS FOR A NON-IMPACT GLAZED DOOR. | | | SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR STORM PANELS | | | AND INSTALLATION SCHEDULES FOR THE NEW GLAZED DOORS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-03-26 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-03-26 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-03-26 |
Time |
10:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-03-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-03-08 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-03-08 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2012-03-08 13:08:23 | 12030094 | | | 1449 8TH ST. | | | INTERIOR RENOVATION | | | | | | PROVIDE AN ELECTRIC SERVICE RISER PLAN WITH WIRE SIZES, | | | GROUNDING ETC. INDICATE THE LOCATION OF THE SERVICE. | | | SHOW LOCATION OF MAIN BREAKER AND METER. NEC 215.15 | | | THE MAIN SERVICE DISCONNECT MUST BE LOCATED NEAREST THE | | | POINT OF ENTRANCE OF THE SERVICE CONDUCTORS. NEC 230.70 | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE DETECTORS IF THEY DO NOT | | | ALREADY EXIST WITHIN THE RESIDENCE. IF THE RESIDENCE | | | HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE | | | A CARBON MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET | | | OF EACH ROOM USED FOR SLEEPING. FBC R313 | | | FOR THE NEW WALL SPACES ADD RECEPTACLES SO THAT NO WALL | | | SPACE IS MORE THAN 6 FEET FROM A RECEPTACLE AND ALL | | | WALL SPACES MORE THAN 2 FEET IN WIDTH HAVE A RECEPTACLE | | | I.E. NEW CLOSET WALL. NEC 210.52 | | | AN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN | | | SERVICE GROUND. 2008 NEC 250.94 | | | ALL NEW RECEPTACLES SHALL BE TAMPER RESISTANT. 2008 NEC | | | 406.11 | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-29 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-23 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2012-03-23 10:03:38 | TO ELECTRIC |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-19 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-06 |
Time |
11:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2012-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-19 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-19 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2012-03-19 08:29:47 | NO MECHANICAL WORK IS SHOWN ON THE PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-29 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-29 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-19 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-19 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2012-03-19 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-03-19 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-19 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
|