Plan Review Details - Permit 12020712
Plan Review Stops For Permit 12020712
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2012-06-22 Cont ID  
Sent By shill Date 2012-06-22 Time 11:02 Rev Time 0.00
Received By shill Date 2012-06-22 Time 11:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2012-06-21 Cont ID  
Sent By shill Date 2012-06-21 Time 11:21 Rev Time 0.00
Received By shill Date 2012-06-21 Time 11:20 Sent To  
Notes
2012-06-21 11:22:14****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
  
 1. OUR RECORDS SHOW THAT THE EXTERIOR DOORS ON THE
 PROPERTY LINE ARE CURRENTLY INSWING DOORS. DOORS CANNOT
 ENCROACH THE PUBLIC SIDEWALK FBC 3202.2.
  
 3RD REVIEW, PLAN REVISED BUT PRODUCT APPROVAL IS FOR
 OUTSWING. SUBMIT NEW PRODUCT APPROVALS FOR INSWING
 DOORS.
  
 2-4. OK
  
 5. THIS PROPERTY HAS SEVERAL EXPIRED PERMITS/PERMIT
 APPLICATIONS. PLEASE ADDRESS.
  
 3RD REVIEW, PLEASE ADDRESS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-04-11 Cont ID  
Sent By shill Date 2012-04-11 Time 13:28 Rev Time 0.00
Received By shill Date 2012-04-11 Time 13:28 Sent To  
Notes
2012-04-11 14:09:42****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
  
 1. OUR RECORDS SHOW THAT THE EXTERIOR DOORS ON THE
 PROPERTY LINE ARE CURRENTLY INSWING DOORS. DOORS CANNOT
 ENCROACH THE PUBLIC SIDEWALK FBC 3202.2.
  
 2. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB WITH
 COST BREAKDOWNS.
  
 3. SEE TABLE 2, SHEET 5 OF SHUTTER NOA FOR REQUIRED
 SEPARATION TO GLASS AND REVISE INSTALLATION SCHEDULE
 ACCORDINGLY.
  
 4. THE SHUTTER CONNECTION MOUNTING TYPE SHOULD
 CORRELATE WITH THE ANCHOR CHARTS (IN THIS CASE, C1
 THROUGH C5). PLEASE REVISE.
  
 **NEW COMMENT 5/17**
  
 5. THIS PROPERTY HAS SEVERAL EXPIRED PERMITS/PERMIT
 APPLICATIONS. PLEASE ADDRESS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-03-09 Cont ID  
Sent By shill Date 2012-03-09 Time 09:43 Rev Time 0.00
Received By shill Date 2012-03-09 Time 09:43 Sent To  
Notes
2012-03-09 09:45:04****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. FOR THE PROPOSED SHUTTERS, COMPLETE THE SAMPLE
 INSTALLATION SCHEDULE OR PROVIDE ALL INFORMATION TO
 SHOW CODE COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC
 R301, FBC1609. TWO SETS REQUIRED. THIS FORM IS
 AVAILABLE IN THE LOBBY OR ON THE INTERNET AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 2. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS WILL
 BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH THE
 INSTALLATION SCHEDULE, ITEM 2 ABOVE. FBC R301, FBC1609,
 FBC*106. SHOW LOCATIONS AND SIZES OF PROPOSED WINDOWS,
 DOORS.
  
 3. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4.
  
 4. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR
 SHUTTERS, DOORS.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-06-21 Cont ID  
Sent By shill Date 2012-06-21 Time 11:22 Rev Time 0.00
Received By shill Date 2012-06-14 Time 16:05 Sent To  
Notes
2012-06-14 16:05:16TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-04-11 Cont ID  
Sent By shill Date 2012-04-11 Time 14:09 Rev Time 0.00
Received By shill Date 2012-04-05 Time 16:10 Sent To  
Notes
2012-04-05 16:10:41SENT TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-03-09 Cont ID  
Sent By shill Date 2012-03-09 Time 09:59 Rev Time 0.00
Received By shill Date 2012-02-28 Time 16:26 Sent To  
Notes
2012-02-28 16:26:48TO BLDG < $5K


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved