Plan Review Details - Permit 12020074
| Plan Review Stops For Permit 12020074 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-03-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-03-29 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-03-29 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2012-03-29 11:49:45 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. OUR RECORDS SHOW THAT THE WALL HAS NOT OBTAINED THE | | | LEGALLY REQUIRED INSPECTIONS. THIS MUST BE ADDRESSED | | | PRIOR TO ISSUANCE OF A PERMIT TO ALTER THE WALL. PLEASE | | | APPLY FOR A REISSUE PERMIT TO OBTAIN THE REQUIRED FINAL | | | INSPECTION. | | | | | | 2. OUR RECORDS SHOW A 12"X16" FOOTING FOR THE EXISTING | | | WALL. IT DOES NOT APPEAR THAT THIS IS ADEQUATE TO | | | SUPPORT LOADS REQUIRED FOR THE PROPOSED IMPROVEMENT. | | | EITHER ENGINEERING OR CALCULATIONS WILL BE REQUIRED. | | | | | | 3. THERE IS A PARCEL HOLD PLACED ON THIS PROPERTY WHICH | | | STATES THAT NEIGHBORS REPORTED THAT THERE WAS DAMAGE TO | | | THE EAST AND WEST. THIS ISSUE WILL BE ADDRESSED DURING | | | THE REISSUE PROCESS FOR THE WALL PREVIOUSLY | | | CONSTRUCTED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-02-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-02-14 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-02-14 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2012-02-14 10:56:45 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PROVIDE A STRUCTURAL DETAIL TO SHOW HOW THIS | | | PROPOSED IMPROVEMENT WILL RESIST WIND LOADS, FBC R301. | | | DETAIL IS TO INCLUDE WIND DESIGN CRITERIA, (140MPH, | | | EXPOSURE C). ENGINEERING MAY BE REQUIRED. | | | | | | 2. AS DISCUSSED, PLEASE PROVIDE A COPY OF THE EXISTING | | | WALL PLAN. AS DISCUSSED, IF POSSIBLE, CALL ME TO SEE | | | THE PLAN PRIOR TO SUBMITTAL TO DETERMINE WHETHER THE | | | EXISTING FOOTER WILL BE ADEQUATE. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-03-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-03-29 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-03-23 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-02-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-02-14 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-02-03 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2012-02-03 10:29:46 | TO ZONING | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2012-02-10 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2012-02-10 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2012-02-10 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2012-02-10 17:11:07 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | PASSED W PROVISO | | | MAX HEIGHT WITHIN FRONT SETBACK: 4 FT. + 10% OR 53 | | | INCHES | | | MAX HEIGHT BEYOND THE FRONT SETBACK: 6 FT. + 10% OR 79 | | | INCHES | | | |
|
|
|