| 2012-02-01 08:25:53 | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 12010663 |
| | ADD: 801 S OLIVE AVE # 708 |
| | CONT: NEW CITY CONSTRUCTION |
| | TEL: (561)541-6160 |
| | |
| | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH |
| | THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, |
| | BUILDING. |
| | |
| | CODE SUMMARY/ RED LINED: |
| | TYPE OF CONSTURCTION : IA |
| | OCCUPANCY TYPE: R2 |
| | |
| | BUILDING PROVISO: |
| | |
| | 1) MISSING FLOOR SOUND PROOFING DOCUMENTATION, |
| | CONTRACTOR TO HAVE AT JOBSITE FOR INSPECTOR TO BRING |
| | IN FOR THE BUILDING DEPARTMENT CITY FILES. |
| | 2007/09 FBC-B 1207.3 STRUCTURE-BORNE SOUND. |
| | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT |
| | INSULATION CLASS (IIC) RATING OF NOT LESS THAN 50 (45 |
| | IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH |
| | ASTM E 492. |
| | |
| | 2) 2509.2 BASE FOR TILE. CEMENT, FIBER-CEMENT OR GLASS |
| | MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM |
| | C 1178, C 1288 OR C 1325 AND INSTALLED IN ACCORDANCE |
| | WITH MANUFACTURER RECOMMENDATIONS SHALL BE |
| | USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS |
| | AND WALL AND CEILING PANELS IN SHOWER AREAS. |
| | WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A |
| | BASE FOR TILE IN WATER CLOSET COMPARTMENT |
| | WALLS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM |
| | C 840 AND MANUFACTURER RECOMMENDATIONS. |
| | REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR |
| | WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN |
| | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |