| Plan Review Stops For Permit 12010525 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2012-04-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-18 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-18 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-04-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-10 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-10 |
Time |
06:46 |
Sent To |
|
|
| Notes |
| 2012-04-10 09:34:26 | OWNER/AGENT NEEDS TO SIGN BOTH SETS OF ENERGY | | | CALCULATIONS FOR DUPLEX B. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-02-13 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-02-13 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2012-02-13 14:57:26 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE ENGINEER OF RECORD SIGNED AND DATED THE PLANS, | | | BUT DID NOT SEAL THEM AS REQUIRED BY FS 471.025 (1). | | | | | | 2) THE ENERGY CALCULATIONS FOR EACH UNIT ARE REQUIRED | | | TO BE SIGNED BY THE OWNER/AGENT PER FBCR ENERGY GLITCH | | | AMENDMENTS N1100.2.2. | | | | | | 3) PLAN SHEET S-1 SPECIFIES A LARGE MISSILE IMPACT | | | RATED BATHROOM WINDOW AND EXPIRED NOA #07-0815.09. THE | | | PRODUCT APPROVAL THAT WAS SUBMITTED IS FOR A NON-IMPACT | | | WINDOW. PLEASE CLARIFY. CITY AMENDMENTS 106.1 | | | | | | 4) PLEASE CLARIFY WHICH WINDOWS ON THE PLANS ARE BEING | | | REPLACED. CITY AMENDMENTS 106.1 | | | | | | 5) SHOW COMPLIANCE WITH FBCR 301.2.1.2 FOR PROTECTION | | | OF GLAZED OPENINGS. PROVIDE TWO COPIES OF THE | | | FOLLOWING: PRODUCT APPROVAL FOR THE STORM PANELS, KEY | | | PLAN AND INSTALLATION SCHEDULE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-03-27 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-03-27 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-03-27 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-01-31 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-01-31 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-01-30 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2012-01-31 08:58:01 | 12010525 | | | 335 KENILWORTH BLVD. | | | INTERIOR RENOVATION | | | | | | PROVIDE AN ELECTRICAL RISER PLAN SHOWING THE MAIN | | | DISCONNECTS GROUNDING AND SERVICE CONDUCTORS. AN | | | INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN | | | SERVICE GROUND NEC 250.94, NEC 215.5 | | | PROVIDE A GFCI PROTECTED RECEPTACLE AT EACH ENTRANCE. | | | NEC 210.52 | | | ALL RECEPTACLES SERVING KITCHEN COUNTER TOP SURFACES | | | MUST BE GFCI PROTECTED. NEC 210.8 | | | LOAD CALCULATION DID NOT INCLUDE AN ELECTRIC RANGE. NEC | | | 220.10 | | | IF THE RESIDENCE HAS GAS APPLIANCES, AN ATTACHED GARAGE | | | OR A FIRE PLACE A CARBON MONOXIDE DETECTOR IS REQUIRED | | | WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING. FBC | | | R313 | | | | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-03-27 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2012-03-27 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2012-03-26 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-02-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2012-02-07 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2012-01-25 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2012-02-07 11:15:47 | PROPERTY LOCATED IN CENTRAL PARK HISTORIC DISTRICT. | | | APPLICANT SHALL PROVIDE WINDOW SCHEDULE, CLEARLY | | | INDICATING WHICH WINDOWS ARE TO BE REPLACED. SINGLE | | | HUNG 1/1 WINDOWS REQUIRED, ORIGINAL OPENING SIZES TO | | | REMAIN. QUESTIONS CONTACT FRIEDERIKE MITTNER, CITY | | | HISTORIC PRESERVATION PLANNER AT (561) 822-1457. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-04-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-20 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-18 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2012-04-18 11:20:44 | SENT TO ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-04-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-10 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-15 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2012-03-16 11:26:34 | INCOMING SENT TO R04. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-02-13 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-01-25 |
Time |
16:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2012-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-02-13 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-02-13 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-04-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-09 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-09 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2012-04-09 16:14:05 | MECHANICAL PROVISO | | | | | | AIR-HANDLERS LOCATED IN ATTICS SHALL COMPLY WITH FBCR | | | M1305.1.3 AND M1305.1.3.2. THE SERVICE PANEL OF THE | | | EQUIPMENT SHALL BE LOCATED WITHIN 6 FEET OF AN ATTIC | | | ACCESS. THE ACCESS SHALL BE OF SUFFICIENT SIZE TO | | | REPLACE THE UNIT. A PASSAGE WAY NOT LESS THAN 30 INCHES | | | HIGH AND 22 INCHES WIDE AND NOT MORE THAN 6 FEET IN | | | LENGTH WITH CONTINUOUS SOLID FLOORING NOT LESS THAN 24 | | | INCHES WIDE IS REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-02-13 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-02-13 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2012-02-13 13:22:18 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY MECHANICAL | | | | | | 1) THE MECHANICAL PLANS ARE NOT SEALED BY THE ENGINEER, | | | AS REQUIRED BY FS 471.025(1). | | | | | | 2) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED | | | BY THE OWNER/AGENT AS REQUIRED BY FBCR ENERGY GLITCH | | | AMENDMENTS N1100.2.2. | | | | | | 3) SHOW COMPLIANCE WITH FBCR SECTION M1305 FOR ACCESS | | | TO AIR HANDLERS. ALSO SEE FBCR M1305.1 THROUGH | | | M1305.1.3.2. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-04-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-09 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-09 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2012-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-02-13 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-02-13 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2012-02-13 10:19:01 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY PLUMBING | | | | | | 1) THE VENTING SHOWN ON THE PLANS IS NOT CODE | | | COMPLIANT. FBCR P3108.2 VENT CONNECTIONS.THE DRY VENT | | | CONNECTION TO THE WET VENT SHALL BE AN INDIVIDUAL VENT | | | OR COMMON VENT TO THE LAVATORY, BIDET, SHOWER OR | | | BATHTUB. IN VERTICAL WET VENT SYSTEMS, THE MOST | | | UPSTREAM FIXTURE DRAIN CONNECTION SHALL BE A DRY-VENTED | | | FIXTURE DRAIN CONNECTION. IN HORIZONTAL WET-VENT | | | SYSTEMS, NOT MORE THAN ONE WET-VENTED FIXTURE DRAIN | | | SHALL DISCHARGE UPSTREAM OF THE DRY-VENTED FIXTURE | | | DRAIN CONNECTION. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2012-04-19 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-04-19 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-04-19 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2012-04-19 12:06:04 | GIVEN TO JR |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2012-03-26 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-03-26 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-03-22 |
Time |
09:25 |
Sent To |
HIST |
|
| Notes |
| 2012-03-26 16:28:01 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 03.26.2012 | | | PERMIT NO.: 12010525 | | | ADDRESS: 335 KENILWORTH BOULEVARD | | | CONTRACTOR/CONTACT: PRIMUS CONSTRUCTION | | | TELEPHONE NO.: 954.316.0044 | | | SCOPE OF REVIEW: INTERIOR RENOVATION AND WINDOWS. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. AS INDICATED IN OUR PHONE CONVERSATION ON 3/26/2012, | | | THE SUBJECT PROPERTY IS ZONED MULTIFAMILY MEDIUM | | | DENSITY (MF20) RESIDENTIAL ? CONTEXT 1. BASED UPON THE | | | SIZE OF THE LOT, THE SUBJECT PROPERTY IS ONLY PERMITTED | | | A SINGLE FAMILY DWELLING UNIT, OR A DUPLEX. ACCORDING | | | TO THE CITY'S PROPERTY RECORDS, THERE IS AN EXISTING | | | DUPLEX, AS WELL AS A THIRD RESIDENTIAL UNIT IN THE | | | DETACHED STRUCTURE IN THE REAR. AS SUCH, THE PROPERTY | | | IS A NON-CONFORMING USE. PURSUANT TO SECTION | | | 94-513(B)(1) OF THE CITY'S ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDRS), RENOVATIONS OR REPAIRS MAY ONLY BE | | | MADE PROVIDED THAT THE COSTS INCURRED DO NOT EXCEED 50 | | | PERCENT OF THE VALUE OF THE STRUCTURE. ACCORDING THE | | | PALM BEACH COUNTY PROPERTY APPRAISER, THE VALUE OF THE | | | STRUCTURE BEING RENOVATED IS $29,557; THEREFORE, THE | | | VALUE OF THE IMPROVEMENTS SHALL NOT EXCEED $14,778.50. | | | | | | TO ADDRESS THE COMMENT ABOVE, THERE ARE A COUPLE OF | | | OPTIONS: | | | | | | A. AS DISCUSSED, THE VALUE AND/OR SCOPE OF WORK CAN BE | | | REDUCED SO THAT IT IS AT OR BELOW $14,778.50; CABINETRY | | | AND TILE WORK COULD BE REMOVED FROM THE CURRENT PERMIT | | | VALUE. IN ORDER TO DO THIS, A COVER LETTER WOULD NEED | | | TO BE PROVIDED SHOWING THE BREAK-DOWN IN THE COST OF | | | CONSTRUCTION, ALONG WITH SUPPORTING DOCUMENTATION (I.E. | | | CONTRACT) CONFIRMING THE VALUE RELATIVE TO THE SCOPE OF | | | WORK. | | | | | | B. PROVIDE A PROVIDE APPRAISAL SHOWING THE VALUE OF | | | THAT STRUCTURE. IF THE VALUE SHOWN ON THE PRIVATE | | | APPRAISAL IS HIGHER THAN THE PROPERTY APPRAISER'S, THEN | | | THAT VALUE COULD BE UTILIZED TO DETERMINE THE 50 | | | PERCENT THRESHOLD. | | | | | | C. REMOVE THE THIRD RESIDENTIAL UNIT THAT IS LOCATED IN | | | THE REAR STRUCTURE SO THAT THERE ARE ONLY TWO (2) | | | RESIDENTIAL UNITS LOCATED ON THE PROPERTY. | | | | | | 2. IF THE VALUE OF THE PROPOSED WORK CONTINUES TO | | | EXCEED 50 PERCENT OF THE VALUE OF THE STRUCTURE, A | | | SEPARATE LANDSCAPE PERMIT APPLICATION WILL NEED TO BE | | | SUBMITTED. THE LANDSCAPE PERMIT APPLICATION SHALL | | | INCLUDE TWO (2) COPIES OF SIGNED/SEALED LANDSCAPE PLAN, | | | BY A REGISTERED LANDSCAPE ARCHITECT, SHOWING COMPLIANCE | | | WITH ALL OF THE PROVISIONS OF ARTICLE XIV OF THE CITY'S | | | ZLDRS. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2012-02-10 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2012-02-10 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-02-10 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2012-02-10 10:51:56 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.10.2012 | | | PERMIT NO.: 12010525 | | | ADDRESS: 335 KENNILWORTH | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: INTERIOR RENOVATION TO EXISTING | | | RESIDENCE. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. AS THE VALUE OF THE PROPOSED IMPROVEMENTS EXCEEDS 50 | | | PERCENT OF THE ASSESSED VALUE OF THE STRUCTURE, THE | | | PROPERTY SHALL BE BROUGHT IN COMPLIANCE WITH ARTICLE | | | XIV (LANDSCAPING) OF THE CITY'S ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDRS). | | | | | | A LANDSCAPE PERMIT APPLICATION SHALL BE SUBMITTED WITH | | | TWO (2) COPIES OF A LANDSCAPE PLAN, AND A CERTIFIED | | | COST ESTIMATE. THE LANDSCAPE PLAN SHALL INDICATE ALL | | | EXISTING AND PROPOSED TREES/SHRUBS/GROUNDCOVER/ETC AND | | | A TABULATION TABLE INDICATING COMPLIANCE WITH ARTICLE | | | XIV. | | | | | | IF THE EXISTING LANDSCAPING CURRENTLY CONFORMS TO THE | | | MINIMUM STANDARDS OF ARTICLE XIV AND NO ADDITIONAL WORK | | | IS NEEDED, SIMPLY PROVIDE A PLAN INDICATING ALL OF THE | | | EXISTING LANDSCAPING, ALONG WITH A TABULATION TABLE, | | | INDICATING COMPLIANCE WITH SUCH. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|