| 2012-02-15 12:32:15 | R06 | | 2012-02-08 10:57:50 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- PLEASE PROVIDE PRODUCT APPROVALS (2 COPIES) AS | | | REQUIRED BY DCA RULE 9N-3 FOR: | | | A) CLAY ROOF TILE AS SPECIFIED ON PLANS. AND, CLEARLY | | | SPECIFY INSTALLATION METHOD FOAM OR SCREWS. | | | | | | B) FOAM IF USING FOAM FOR CLAY ROOF TILE INSTALLATION. | | | SEE TILE PRODUCT APPROVAL FOR LISTED FOAM. | | | | | | C) WINDOW MULLIONS AS SHOWN ON PLANS. AND, CLEARLY | | | SPECIFY ON PRODUCT APPROVAL MULLION SIZE AND ANCHORING | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS PRIOR | | | TO SUBMITTAL TO THIS OFFICE AS REQUIRED BY SEC. 106.3.3 | | | CITY AMENDMENTS TO FBC. | | | ***NOTE: SOME PRODUCT APPROVALS SUBMITTED ARE NOT THE | | | SAME AS THE ONES THAT WERE SPECIFIED ON THE DOOR/WINDOW | | | SCHEDULES. REVISE AS REQUIRED TO MATCH. | | | | | | 3- REVISE ALL DETAILS AND WALL SECTIONS TO SHOW THE | | | R-VALUE FOR THE CEILINGS AND WALLS INSULATION AS | | | SPECIFIED ON THE ENERGY CALCULATIONS. | | | | | | 4- SPECIFY ATTIC ACCESS SIZE AND LOCATION FOR NEW ATTIC | | | AREA IN THE FAMILY ROOM AS REQUIRED BY SEC. R807. | | | | | | 5- SHEET A-1: A) LEGAL DESCRIPTION SHOWN ON THE SITE | | | PLAN IS FOR A PROPERTY IN MIAMI-DADE. REVISE. | | | | | | B) DEMOLITION NOTES SPECIFY FBC 2004. REVISE TO CURRENT | | | CODE. | | | | | | 6- SHEET A-2: REVISE GENERAL CONSTRUCTION NOTE #2. MIN. | | | WIDTH OF ATTIC ACCESS IS 22" NOT 20". SEC. R807. | | | | | | 7- FENCES REQUIRE SEPARATE PERMIT. PROVIDE COMPLETE | | | INFORMATION UNDER A SEPARATE PERMIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-03-16 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-03-16 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-03-16 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-01-30 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-01-30 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-01-30 |
Time |
16:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-03-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-03-23 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-03-16 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-03-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-03-09 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-02-15 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-02-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-02-09 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-01-23 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2012-03-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-03-23 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-03-23 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2012-03-23 16:28:01 | MECHANICAL REVIEW APPROVED WITH PROVISO: | | | | | | 1- REVISE THE COOLING AND HEATING INFORMATION ON THE | | | ENERGY CALCULATIONS TO MATCH THE INFORMATION ON THE | | | EQUIPMENT SIZING CALCULATIONS SUBMITTED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2012-03-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-03-23 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-03-23 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2012-03-23 13:56:47 | RESIDENTIAL (R3) MECHANICAL REVIEW THIRD CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | | | | ORIGINAL COMMENT: | | | 1- INFORMATION SUBMITTED ON THE ENERGY CALCULATIONS | | | DOESN'T MATCH INFORMATION SUBMITTED ON THE RESIDENTIAL | | | SYSTEM SIZING CALCULATIONS. REVISE ENERGY CALCULATIONS | | | AS REQUIRED TO MATCH. CHECK THE TOTAL COOLING CAPACITY | | | AND TOTAL HEATING CAPACITY. | | | | | | RESPONSE TO RE-SUBMITAL: | | | REVISED ENERGY CALCULATIONS STATE "REPLACEMENT FOR | | | WHOLEHOUSE". THIS INFORMATION IS INCOMPLETE BECAUSE | | | EVEN IF IT'S A REPLACEMENT, THEN, THE CAPACITY SHALL | | | MATCH THE EQUIPMENT SIZING CALCULATIONS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2012-03-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-03-09 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-03-09 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2012-03-09 16:44:50 | RESIDENTIAL (R3) MECHANICAL REVIEW SECOND CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | ***NOTE: THERE WAS NOT RE-SUBMITTAL TO ADDRESS ANY OF | | | THE ISSUES. SAME COMMENTS FROM THE FIRST REVIEW APPLY: | | | | | | 1- INFORMATION SUBMITTED ON THE ENERGY CALCULATIONS | | | DOESN'T MATCH INFORMATION SUBMITTED ON THE RESIDENTIAL | | | SYSTEM SIZING CALCULATIONS. REVISE ENERGY CALCULATIONS | | | AS REQUIRED TO MATCH. CHECK THE TOTAL COOLING CAPACITY | | | AND TOTAL HEATING CAPACITY. | | | | | | 2- BOTH MECHANICAL DRAWINGS NEED TO HAVE THE | | | ARCHITECT'S ORIGINAL EMBOSSED SEAL AS REQUIRED BY | | | CHAPTER 481 FLORIDA STATUTES. ONLY ONE COPY SUBMITTED | | | HAS EMBOSSED SEAL. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-02-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-02-08 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-02-08 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2012-02-08 15:33:27 | RESIDENTIAL (R3) MECHANICAL REVIEW COMMENTS. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- INFORMATION SUBMITTED ON THE ENERGY CALCULATIONS | | | DOESN'T MATCH INFORMATION SUBMITTED ON THE RESIDENTIAL | | | SYSTEM SIZING CALCULATIONS. REVISE ENERGY CALCULATIONS | | | AS REQUIRED TO MATCH. CHECK THE TOTAL COOLING CAPACITY | | | AND TOTAL HEATING CAPACITY. | | | | | | 2- BOTH MECHANICAL DRAWINGS NEED TO HAVE THE | | | ARCHITECT'S ORIGINAL EMBOSSED SEAL AS REQUIRED BY | | | CHAPTER 481 FLORIDA STATUTES. ONLY ONE COPY SUBMITTED | | | HAS EMBOSSED SEAL. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-03-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-03-14 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-03-14 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2012-02-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-02-09 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-02-08 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2012-02-09 09:51:42 | RESIDENTIAL (R3) PLUMBING REVIEW COMMENTS. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- PLEASE PROVIDE SANITARY ISOMETRIC RISER DIAGRAM AS | | | REQUIRED BY SEC. 106.3.5.4(9) OF CITY AMENDMENTS TO | | | FBC. CLEARLY SHOW ALLL PIPES SIZES, AL VENTS, ETC. | | | ***NOTE: PLUMBING CONTRACTOR MAY DRAW RISER SHOWING | | | PROPOSED WORK WHEN PROVIDING NAME, LICENSE NUMBER AND | | | SIGNATURE ON THE DRAWING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2012-03-23 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-03-23 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-03-23 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2012-03-23 15:44:03 | PROVISO....ALL LANDSCAPING PROPOSED UNDER PERMIT | | | #12030421 SHALL BE INSTALLED, INSPECTED, AND PASSED | | | PRIOR TO THE ISSUANCE OF A CERTIFICATE OF | | | COMPLETION/OCCUPANCY. QUESTIONS/COMMENTS, CONTACT JOHN | | | ROACH, SENIOR PLANNER, AT (561) 822-1448. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2012-03-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-03-06 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-02-29 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2012-03-07 13:43:52 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 03.06.2012 | | | PERMIT NO.: 12010451 | | | ADDRESS: 325 FOREST HILL BOULEVARD | | | CONTRACTOR/CONTACT: HERNAN ZURITA | | | TELEPHONE NO.: 561.753.3428 | | | SCOPE OF REVIEW: NEW ENTRY PORCH AND INTERIOR | | | RENOVATIONS TO EXISTING RESIDENCE. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. AS NEW LANDSCAPING IS BEING INSTALLED, A SEPARATE | | | LANDSCAPE PERMIT APPLICATION SHALL BE SUBMITTED TO | | | CONSTRUCTION SERVICES WITH TWO (2) COPIES OF A | | | LANDSCAPE PLAN, AND A CERTIFIED COST ESTIMATE. THE | | | LANDSCAPE PLAN SHALL INDICATE ALL EXISTING AND PROPOSED | | | TREES/SHRUBS/GROUNDCOVER/ETC AND A TABULATION TABLE | | | INDICATING COMPLIANCE WITH ARTICLE XIV. THE TABLE SHALL | | | NOTE THE BOTANICAL AND COMMON NAMES, QUANTITY, HEIGHT, | | | SPREAD, SPACING OF ALL PROPOSED PLAN MATERIALS. | | | | | | 2. PLEASE NOTE THAT PALMS CAN ONLY BE USED FOR A | | | MAXIMUM OF 35 PERCENT OF THE REQUIRED SHADE TREES. | | | | | | 3. PLEASE NOTE THE QUALITY OF THE PLANT MATERIAL TO BE | | | INSTALLED....ALL MATERIALS SHALL BE EQUAL TO OR BETTER | | | THAN FLORIDA DEPARTMENT OF AGRICULTURE NUMBER 1 NUSERY | | | GRADE STANDARD. | | | | | | 4. ALL REQUIRED TREES SHALL BE A MINIMUM OF 8 FEET IN | | | HEIGHT, AND POSSESS A CLEAR TRUNK OF AT LEAST 5 FEET IN | | | HEIGHT. | | | | | | 5. SHURBS SHALL BE A MINIMUM PLANT CONTAINER SIZE OF AT | | | 2 GALLONS. | | | | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2012-02-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-02-06 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-02-03 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2012-02-06 09:55:42 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.03.2012 | | | PERMIT NO.: 12010451 | | | ADDRESS: 325 FOREST HILL BOULEVARD | | | CONTRACTOR/CONTACT: HERNAN ZURITA | | | TELEPHONE NO.: 561.753.3428 | | | SCOPE OF REVIEW: NEW ENTRY PORCH AND INTERIOR | | | RENOVATIONS TO EXISTING RESIDENCE. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. AS THE VALUE OF THE PROPOSED IMPROVEMENTS EXCEEDS 50 | | | PERCENT OF THE ASSESSED VALUE OF THE STRUCTURE, THE | | | PROPERTY SHALL BE BROUGHT IN COMPLIANCE WITH ARTICLE | | | XIV (LANDSCAPING) OF THE CITY'S ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDRS). | | | | | | A LANDSCAPE PERMIT APPLICATION SHALL BE SUBMITTED WITH | | | TWO (2) COPIES OF A LANDSCAPE PLAN, AND A CERTIFIED | | | COST ESTIMATE. THE LANDSCAPE PLAN SHALL INDICATE ALL | | | EXISTING AND PROPOSED TREES/SHRUBS/GROUNDCOVER/ETC AND | | | A TABULATION TABLE INDICATING COMPLIANCE WITH ARTICLE | | | XIV. | | | | | | IF THE EXISTING LANDSCAPING CURRENTLY CONFORMS TO THE | | | MINIMUM STANDARDS OF ARTICLE XIV AND NO ADDITIONAL WORK | | | IS NEEDED, SIMPLY PROVIDE A PLAN INDICATING ALL OF THE | | | EXISTING LANDSCAPING, ALONG WITH A TABULATION TABLE, | | | INDICATING COMPLIANCE WITH SUCH. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|