| Plan Review Stops For Permit 12010450 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2012-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-06-12 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-06-12 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2012-05-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-05-22 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-05-22 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2012-05-22 15:08:19 | OWNER AGENT NEEDS TO SIGN ENERGY CALC. FORM. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-24 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-20 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2012-04-24 16:45:36 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED | | | AND DATED BY THE OWNER/AGENT. 2007 ENERGY GLITCH | | | AMENDMENTS N 1100 | | | | | | 2) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE | | | SIX PANEL METAL FRONT DOOR THAT IS SPECIFIED ON THE | | | PLANS. DCA RULE 9N-3 | | | | | | 3) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. CITY | | | AMENDMENTS 106.3.3 | | | | | | 4) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-02-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-02-15 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-02-15 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2012-02-15 09:12:34 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) PLEASE REVISE THE DESIGN CRITERIA ON SHEET 1.1 TO | | | REFERENCE ASCE 7-05. FBCR CHAPTER 43. | | | | | | 2) UNDER THE EXISTING BUILDING NOTE ON SHEET 1.1 PLEASE | | | CHANGE FROM 2004 FBC TO THE CODE IN EFFECT WHICH IS THE | | | 2007 FBC. | | | | | | 3) SUBMIT TWO SETS OF ENERGY CALCULATIONS AS REQUIRED | | | BY THE 2007 FBCR ENERGY GLITCH AMENDMENTS N 1100. | | | | | | 4) THE POCKET DOOR TO THE ROOM CONTAINING THE WATER | | | CLOSET IS REQUIRED TO HAVE A 29" CLEAR OPENING. FL | | | ACCESSIBILITY CODE SECTION 11-4.22.2 | | | | | | 5) ON SHEET 4.1 THE PLAN SPECIFIES ALL EXTERIOR DOORS | | | TO BE THERMA-TRU WITH CLEAR GLASS, HOWEVER, THE PRODUCT | | | APPROVALS THAT WERE SUBMITTED ARE FROM MASONITE | | | INTERNATIONAL. PLEASE CLARIFY. CITY AMENDMENTS 106.1.1 | | | | | | 6) NOTE (1) FOR THE TRUSS ANCHOR SCHEDULE ON SHEET 5.1 | | | SAYS TO SEE ANCHOR DETAILS ON S-4 FOR THE REQUIRED | | | FASTENERS. THERE IS NO SHEET S-4. THE DETAILS ARE ON | | | SHEET 6.2. PLEASE CORRECT. CITY AMENDMENTS 106.1.1 | | | | | | 7) THE FLORIDA PRODUCT APPROVAL NUMBERS AND THE ANCHOR | | | CAPACITIES LISTED IN THE TRUSS ANCHOR SCHEDULE ON SHEET | | | 5.1 ARE NOT CORRECT. PLEASE REVISE. DCA RULE 9N-3 & FBC | | | R802.1.6.5 | | | | | | 8) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. CITY | | | AMENDMENTS 106.3.3 | | | | | | 9) PLEASE UPDATE THE DESIGN CRITERIA IN THE WINDOW AND | | | DOOR PRESSURE TABLE ON SHEET 6.2 TO THE 2007 FBC AND | | | ASCE 7-05. FBCR CHAPTER 43 | | | | | | 10) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE | | | DOUBLE OUTSWING GLAZED DOORS HAS A MAXIMUM DESIGN | | | PRESSURE OF - 55 PSF AND THE PLAN REQUIRES -58 PSF | | | ACCORDING TO THE TABLE ON SHEET 6.2. PLEASE PROVIDE | | | PRODUCT WITH ADEQUATE DESIGN PRESSURES. DCA RULE 9N-3 | | | | | | 11) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE SIX | | | PANEL METAL FRONT DOOR THAT IS SPECIFIED ON THE PLANS. | | | DCA RULE 9N-3 | | | | | | 12) PLEASE SUBMIT A RESPONSE LETTER THAT INDICATES HOW | | | EACH OF THE REVIEW COMMENTS WAS ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-03-26 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-03-26 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-03-26 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-02-03 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-02-03 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-02-03 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2012-02-03 14:55:13 | PROVIDE THE LOCATION OF THE SERVICE EQUIPMENT AND PANEL | | | BOARD. NEC 215.5 | | | | | | ROBERT LECKY | | | ELECTRIC PLAN REVIEWER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-06-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2012-06-06 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2012-06-06 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2012-06-06 09:38:20 | SENT TO DOUG |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-01-26 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2012-01-26 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2012-01-26 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-05-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-05-22 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-05-14 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2012-05-14 13:43:57 | GAVE TO ROBBIE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-24 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-23 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-02-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-02-15 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-01-23 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2012-05-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-05-22 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-05-22 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2012-05-22 14:31:14 | IMPACT FEES NOT REQUIRED PER PHONE CALL WITH MR. SWOOPE | | | AT P.B.C. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2012-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-24 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-24 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2012-04-24 16:46:53 | AN IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2012-02-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-02-15 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-02-15 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2012-02-15 09:13:16 | CONVERTING STORAGE TO LIVING AREA. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-24 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-24 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-02-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-02-15 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-02-13 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2012-02-14 11:28:34 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY MECHANICAL | | | | | | 1) SUBMIT TWO COPIES OF EQUIPMENT SIZING CALCULATIONS | | | AS REQUIRED BY FBCR M1401.3. | | | | | | 2) PROVIDE AN EQUIPMENT SCHEDULE WITH THE MODEL NUMBERS | | | ON THE MECHANICAL PLANS. FBCR M13.3.1 | | | | | | 3) A SERVICE DISCONNECT, SWITCH CONTROLLED LUMINAIRE | | | AND RECEPTACLE OUTLET ARE REQUIRED AT THE HVAC | | | EQUIPMENT. SHOW COMPLIANCE WITH FBCR M1305.1.3.1. | | | | | | 4) SHOW COMPLIANCE WITH FBCR M1305.1.3 FOR ACCESS TO | | | APPLIANCES IN ATTICS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-04-24 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-04-24 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-02-13 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-02-13 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2012-01-26 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2012-01-26 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2012-01-26 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|