Plan Review Details - Permit 12010225
Plan Review Stops For Permit 12010225
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-03-15 Cont ID  
Sent By jgomez Date 2012-03-15 Time 09:46 Rev Time 0.00
Received By jgomez Date 2012-03-15 Time 09:46 Sent To  
Notes
2012-03-15 09:47:26MIGUEL SENT E-MAIL SHOWING THAT ENGINEER UPDATED HIS
 FIRM INFORMATION. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-03-07 Cont ID  
Sent By jgomez Date 2012-03-07 Time 10:59 Rev Time 0.00
Received By jgomez Date 2012-03-07 Time 08:52 Sent To  
Notes
2012-03-07 11:05:531- ENGINEER TO UPDATE THE CERTIFICATE OF AUTHORIZATION
 FOR THE S.W. ENGINEERING INC. FIRM. ENGINEER TO CONTACT
 THE DEPARTMENT OF BUSINESS & PROFESSIONAL REGULATION
 (DBPR) AND UPDATE AS REQUIRED BY CHAPTER 471 FLORIDA
 STATUTE AND SEC. 61G15-23.002 FLORIDA ADMINISTRATIVE
 CODE FOR ENGINEERS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-01-31 Cont ID  
Sent By jgomez Date 2012-01-31 Time 15:58 Rev Time 0.00
Received By jgomez Date 2012-01-31 Time 14:58 Sent To  
Notes
2012-01-31 16:00:18RESIDENTIAL ADDITON BUILDING REVIEW COMMENTS.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- .PLEASE PROVIDE CURRENT 2008 REVISED ENERGY
 CALCUALTIONS FORM. FORM 600C-01 IS NO LONGER USED.
  
 2- PLEASE BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG
 RD.) TO VERIFY IF IMPACT FEES ARE DUE. THEN, BRING BACK
 STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.
  
 3- ENGINEER TO UPDATE THE CERTIFICATE OF AUTHORIZATION
 FOR THE S.W. ENGINEERING INC. FIRM. ENGINEER TO CONTACT
 THE DEPARTMENT OF BUSINESS & PROFESSIONAL REGULATION
 (DBPR) AND UPDATE AS REQUIRED BY CHAPTER 471 FLORIDA
 STATUTE AND SEC. 61G15-23.002 FLORIDA ADMINISTRATIVE
 CODE FOR ENGINEERS.
  
 4- SHEET 3.0: WALL LEGEND FOR WALL #2 CALLS FOR 2X4
 STUDS AND R-19 MIN. INSULATION. R-19 INSULATION DOESN'T
 FIT ON 2X4 WALL. REVISE AS REQUIRED AND COORDINATE WITH
 THE REVISED ENERGY CALCULATIONS. SEC. 106.1.1 CITY
 AMENDMENTS TO FBC.
  
 5- SHEET 3.1: REVISE DETAIL LEGEND #5. NEED TO PROVIDE
 7/8" STUCCO THICKNESS, NOT 3/4". TABLE R702.1(1).
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR ALL THE SIMPSON STRUCTURAL CONNECTORS
 SPECIFIED BY THE ENGINEER ON PLANS AND DETAILS. PLEASE
 PROVIDE ONLY THE 2007 CODE VERSION PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-01-20 Cont ID  
Sent By rlecky Date 2012-01-20 Time 10:17 Rev Time 0.00
Received By rlecky Date 2012-01-20 Time 10:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2012-04-09 Cont ID  
Sent By jgomez Date 2012-04-09 Time 16:20 Rev Time 0.00
Received By jgomez Date 2012-04-09 Time 16:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2012-04-04 Cont ID  
Sent By jgomez Date 2012-04-02 Time 09:28 Rev Time 0.00
Received By jgomez Date 2012-03-26 Time 10:54 Sent To  
Notes
2012-04-04 09:29:22LAST REVIEW DONE BY ZONING ON 4/2/12. JG.
2012-03-27 10:55:20SENT TO ZONING SHELF FOR ERIC'S REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-03-15 Cont ID  
Sent By jgomez Date 2012-03-15 Time 09:45 Rev Time 0.00
Received By jgomez Date 2012-03-15 Time 09:44 Sent To  
Notes
2012-03-15 09:45:36MIGUEL DE AVILA SENT E-MAIL SHOWING THAT ENGINEER
 UPDATED HIS FIRM INFORMATION. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-03-15 Cont ID  
Sent By jgomez Date 2012-03-08 Time 09:01 Rev Time 0.00
Received By jgomez Date 2012-02-28 Time 15:12 Sent To  
Notes
2012-03-15 09:01:49LAST REVIEW BY ZONING DONE ON 3/8/12. JG.
2012-02-29 14:01:08SENT TO R7 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-01-31 Cont ID  
Sent By jgomez Date 2012-01-31 Time 16:00 Rev Time 0.00
Received By jgomez Date 2012-01-11 Time 16:29 Sent To  
Notes
2012-01-12 16:30:15SENT TO R11 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2012-04-09 Cont ID  
Sent By jgomez Date 2012-04-09 Time 16:20 Rev Time 0.00
Received By jgomez Date 2012-04-09 Time 16:20 Sent To  
Notes
2012-04-09 16:21:42NO FEES DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-01-31 Cont ID  
Sent By jgomez Date 2012-01-31 Time 15:57 Rev Time 0.00
Received By jgomez Date 2012-01-31 Time 15:57 Sent To  
Notes
2012-01-31 15:58:26BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT
 FEES ARE DUE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-03-07 Cont ID  
Sent By jgomez Date 2012-03-07 Time 14:27 Rev Time 0.00
Received By jgomez Date 2012-03-07 Time 14:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-01-31 Cont ID  
Sent By hmoser Date 2012-01-31 Time 14:01 Rev Time 0.00
Received By hmoser Date 2012-01-31 Time 13:48 Sent To  
Notes
2012-01-31 14:06:11PLANS DENIED
 PROVIDE MORE INFORMATION ON THE
 RETURN AIR DUCT SIZE AND WHERE THE DUCT IS GOING.
 REFER TO SECTION M1602.4 BALANCED RETURN AIR
 2007 FBC (R)
 PLAIN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2012-04-02 Cont ID  
Sent By eschneid Date 2012-04-02 Time 11:58 Rev Time 0.50
Received By eschneid Date 2012-03-30 Time 14:19 Sent To PC
Notes
2012-03-30 14:20:07GIVEN TO ES

Review Stop Z ZONING
Rev No 2 Status F Date 2012-03-08 Cont ID  
Sent By eschneid Date 2012-03-08 Time 14:13 Rev Time 0.50
Received By eschneid Date 2012-03-08 Time 14:13 Sent To  
Notes
2012-03-08 14:30:49FAILED
  
 1) REPEAT COMMENT - PROVIDE A RECENT SURVEY OF THE
 PROPERTY. THE SURVEY SHALL SHOW THE DRIVEWAYS INSTALLED
 UNDER PERMIT NOS. 11040056 AND 12020104.
  
 2) REPEAT COMMENT - THE ZONING AND LAND DEVELOPMENT
 REGULATIONS REQUIRE THAT SINGLE FAMILY RESIDENTIAL
 PROPERTIES HAVE TWO (2) ON-SITE PARKING SPACES. THE
 ENCLOSURE OF THE CARPORT REMOVES ONE (1) PARKING SPACE.
 THE EXISTING DRIVEWAY IS NOT LARGE ENOUGH TO
 ACCOMMODATE TWO PARKING SPACES. ZONING WILL NOT APPROVE
 THIS PERMIT UNTIL A BUILDING PERMIT IS SUBMITTED TO
 DEMONSTRATE THAT THERE ARE TWO CODE COMPLIANT ON-SITE
 PARKING SPACES. THE DRAWING PROVIDED WITH PERMIT NO.
 12020104 DOES NOT INDICATE THE WIDTH OF THE NEW
 DRIVEWAY. 2 CARS REQUIRE A 17 FOOT WIDE BY 18 FOOT LONG
 DRIVEWAY TO CONFORM TO THE CITY CODE. THE SURVEY
 REQUIRED IN COMMENT NO. 1 WILL VERIFY THAT THE DRIVEWAY
 WIDTH IS A MINIMUM OF 17 FEET WIDE (PLEASE NOTE THE
 DRIVEWAY MAY NOT EXCEED 20 FEET IN WIDTH) AND 18 FEET
 LONG.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.

Review Stop Z ZONING
Rev No 1 Status F Date 2012-01-18 Cont ID  
Sent By eschneid Date 2012-01-18 Time 17:55 Rev Time 0.25
Received By eschneid Date 2012-01-18 Time 17:55 Sent To  
Notes
2012-01-18 18:04:09FAILED
  
 1) PROVIDE A RECENT SURVEY OF THE PROPERTY. THE SURVEY
 SHALL SHOW THE DRIVEWAY INSTALLED UNDER PERMIT NO.
 11040056.
  
 2) THE ZONING AND LAND DEVELOPMENT REGULATIONS REQUIRE
 THAT SINGLE FAMILY RESIDENTIAL PROPERTIES HAVE TWO (2)
 ON-SITE PARKING SPACES. THE ENCLOSURE OF THE CARPORT
 REMOVES ONE (1) PARKING SPACE. THE EXISTING DRIVEWAY IS
 NOT LARGE ENOUGH TO ACCOMMODATE TWO PARKING SPACES.
 ZONING WILL NOT APPROVE THIS PERMIT UNTIL A BUILDING
 PERMIT IS SUBMITTED TO DEMONSTRATE THAT THERE ARE TWO
 CODE COMPLIANT ON-SITE PARKING SPACES.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved