Plan Review Details - Permit 12010224
| Plan Review Stops For Permit 12010224 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-01-24 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-01-23 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2012-01-24 11:07:23 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-01-18 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-01-11 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2012-01-12 16:44:30 | SENT TO MCDOUGAL'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-01-24 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-01-24 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-01-18 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-01-18 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2012-01-18 11:19:00 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY MECHANICAL | | | | | | 1) THE ORIGINAL MECHANICAL PLANS ARE SIGNED AND SEALED | | | BY THE ARCHITECT, FERNANDO PRIETO. ANY REVISIONS TO THE | | | PLANS ARE REQUIRED TO BE SIGNED AND SEALED BY HIM PER | | | FS 481. | | | | | | 2) THE REVISED PLANS HAVE CONFLICTING EQUIPMENT | | | SCHEDULES. ONE IS FOR GOODMAN UNITS AS SPECIFIED ON THE | | | ORIGINAL PLANS AND THE OTHER IS FOR CARRIER UNITS. | | | PLEASE REMOVE THE ONE THAT IS NOT BEING INSTALLED FROM | | | THE PLANS. CITY AMENDMENTS 106.1.1 | | | | | | 3) THE PROJECT SUMMARY AND LOAD CALCULATIONS FROM | | | CONNIE'S E-CALCS SPECIFY GOODMAN EQUIPMENT. IF CARRIER | | | EQUIPMENT IS USED, REVISED CALCULATIONS ARE REQUIRED. | | | 2007 ENERGY GLITCH AMENDMENTS SECTION N1107.AB. | | | | | | 4) THE CONTRACTOR/COMPANY SPECIFIED ON THE PLANS, | | | TROPICAL A/C & HTG. IS NOT THE CONTRACTOR/COMPANY THAT | | | IS LISTED ON THE PERMIT APPLICATION. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
|