Plan Review Details - Permit 12010206
| Plan Review Stops For Permit 12010206 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-02-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-02-07 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-02-07 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-02-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-02-01 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-02-01 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2012-02-01 14:25:58 | RESIDENTIAL (R3) RENOVATION/ALTERATION BUILDING REVIEW | | | COMMENTS. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- PROVIDE COMPLETE SET OF PLANS AND SPECIFICATIONS TO | | | SHOW ALL WORK TO BE PERFORMED AS SPECIFIED ON THE | | | DESCRIPTION OF PROJECT SHOWN ON THE CONSTRUCTION | | | AGREEMENT SUBMITTED. SEC. 106.1.1 CITY AMENDMENTS TO | | | FBC. | | | | | | A) SHOW DEMOLITION AND REBUILDING OF WALLS. | | | B) SHOW HALF CONCRETE WALL AND FRAME OUT FOR OFFICE | | | AREA. | | | C) SHOW ATTIC PULL DOWN STAIRS LOCATION, FRAMING | | | DETAILS, ETC. AND, PROVIDE ENGINEERING SHOWING THAT | | | EXISTING ROOF SYSTEM IS CAPABLE OF SUPPORTING | | | ADDITIONAL LOAD (STORAGE). SHOW COMPLIANCE WITH TABLE | | | R301.5 FOR ATTIC WITH STORAGE LIVE LOAD. SEE FOOTNOTES | | | ALSO. | | | D) SHOW DEMOLITION AND REBUILDING OF MASTER BATH. | | | E0 SHOW WINDOW REPAIRS/SPECIFICATIONS. | | | F) SHOW ROOF REPAIRS/SPECIFICATIONS. | | | | | | 2- THIS PROPERTY IS LOCATED ON FLOOD ZONE A5. IF THE | | | WORK EXCEEDS 50% OF THE VALUE OF THE STRUCTURE, THIS | | | VALUE IS CUMULATIVE ON THE LIFE OF THE STRUCTURE. THEN, | | | THE ALL HOUSE NEEDS TO COMPLY WITH THE CITY FLOOD | | | MANAGEMENT POLICY. THIS IS ANOTHER REASON WHY THE PLANS | | | SHOWING THE SPECIFIC WORK TO BE PERFORMED IS REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-01-30 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-01-30 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-01-30 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-01-20 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-01-20 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-01-20 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2012-01-20 11:21:59 | 12010206 | | | 122 WORTH CT. N. | | | BATH REMODEL | | | | | | SCOPE OF ELECTRICAL WORK INSUFFICIENTLY DETAILED. | | | ADDITIONAL INFORMATION MAY BE NEEDED. PLEASE PROVIDE | | | THE FOLLOWING: | | | | | | INDICATE THE SIZE AND LOCATION OF THE ELECTRICAL PANEL. | | | PROVIDE A PANEL SCHEDULE AND SUMMARY LOAD CALCULATION. | | | SHOW THE SERVICE LOCATION, FEEDER SIZE AND EXISTING | | | MAIN BREAKER. INCLUDE A FLOOR PLAN SHOWING THE LOCATION | | | OF ALL NEW AND EXISTING OUTLETS INCLUDING LIGHTING. NEC | | | 215.5 | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE DETECTORS IF THEY DO NOT | | | ALREADY EXIST WITHIN THE RESIDENCE. IF THE RESIDENCE | | | HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE | | | A CARBON MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET | | | OF EACH ROOM USED FOR SLEEPING. FBC R313 | | | VERIFY THE BATHROOM RECEPTACLES ARE GFCI PROTECTED. NEC | | | 210.8 | | | INDICATE THAT ALL NEW RECEPTACLES WILL BE TAMPER | | | RESISTANT. NEC 406.11 | | | ALL NEW GENERAL PURPOSE BRANCH CIRCUITS MUST BE | | | PROTECTED WITH ARC FAULT CIRCUIT INTERRUPTERS. NEC | | | 210.12 | | | BATHROOMS EACH REQUIRE A DEDICATED 20 AMP BRANCH | | | CIRCUIT. NEC 210.11 (C) (3) | | | AT LEAST ONE GFCI PROTECTED RECEPTACLE IS REQUIRED | | | OUTSIDE FRONT AND BACK. NEC 210.52 | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-02-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-02-07 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-02-07 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-02-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-02-01 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-01-11 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2012-01-25 11:48:12 | ELECTRIC REVISION ROUTED TO RL | | 2012-01-13 09:00:18 | SENT TO R15 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-02-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-02-07 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-02-07 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2012-02-09 16:40:58 | SCOPE OF WORK NEW SHOWER AS SHOWN ON PLUMBING RISER | | | DIAGRAM. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2012-02-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2012-02-01 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2012-02-01 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2012-02-01 14:30:35 | RESIDENTIAL RENOVATION/ALTERATION PLUMBING REVIEW | | | COMMENTS. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- CLARIFY IF REPLACING EXISTING PLUMBING FIXTURES OR | | | IF RELOCATING AND ADDING NEW PLUMBING FIXTURES. | | | INFORMATION SUBMITTED DOESN'T PROVIDE THIS | | | CLARIFICATION. PROVIDE PLUMBING RISER DIAGRAM IF DOING | | | OTHER THAN JUST REPLACING EXISTING PLUMBING FIXTURES. | | | SEC. 106.3.5.4(9) CITY AMENDMENTS TO FBC. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2012-01-18 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2012-01-18 |
Time |
18:09 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2012-01-18 |
Time |
18:09 |
Sent To |
|
|
| Notes |
| 2012-01-18 18:11:59 | WORK VALUE LESS THAN 50% OF STRUCTURE. |
|
|
|