Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-01-11 Cont ID  
Sent By jgomez Date 2012-01-11 Time 10:54 Rev Time 0.00
Received By jgomez Date 2012-01-11 Time 10:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-01-06 Cont ID  
Sent By jgomez Date 2012-01-06 Time 11:20 Rev Time 0.00
Received By jgomez Date 2012-01-06 Time 09:14 Sent To  
Notes
2012-01-06 11:36:09RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- UNDERLAYMENT FLORIDA PRODUCT APPROVAL FL14317-R1
 SUBMITTED: ACCORDING TO LIMITATION 5.5.2.1 THE MAXIMUM
 DESIGN PRESSURE IS -45PSF FOR A DIRECT BOND DECK
 UNDERLAYMENT. DESIGN PRESSURES FOR THE PERIMETER AND
 CORNER AREAS ARE HIGHER FOR THIS BUILDING. THIS PRODUCT
 CAN'T NOT BE USED. REVISE AS REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL ME:
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712