Plan Review Details - Permit 12010023
Plan Review Stops For Permit 12010023
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-01-24 Cont ID  
Sent By rmcdouga Date 2012-01-24 Time 14:38 Rev Time 0.00
Received By rmcdouga Date 2012-01-24 Time 14:33 Sent To  
Notes
2012-01-24 14:39:40SEE ELECTRIC REVIEW COMMENTS FOR CARBON MONOXIDE AND
 SMOKE ALARMS.
2012-01-20 09:42:47 
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-02-08 Cont ID  
Sent By rlecky Date 2012-02-08 Time 10:16 Rev Time 0.00
Received By rlecky Date 2012-02-08 Time 10:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-01-20 Cont ID  
Sent By rlecky Date 2012-01-20 Time 09:41 Rev Time 0.00
Received By rlecky Date 2012-01-20 Time 09:31 Sent To  
Notes
2012-01-24 14:36:2412010023
 734 NEW YORK STREET
 KITCHEN REMODEL
  
 SCOPE OF ELECTRICAL WORK INSUFFICIENTLY DETAILED.
 PLEASE PROVIDE THE FOLLOWING:
  
 INDICATE THE SIZE AND LOCATION OF NEW ELECTRICAL PANEL.
 PROVIDE A PANEL SCHEDULE AND LOAD CALCULATION. SHOW THE
 SERVICE LOCATION, FEEDER SIZE AND EXISTING MAIN
 BREAKER. INCLUDE KITCHEN LAY OUT SHOWING LOCATION OF
 ALL NEW AND EXISTING RECEPTACLES. IF THIS IS A NEW
 SERVICE ADDITIONAL INFORMATION MAY BE NEEDED. NEC 215.5
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE DETECTORS IF THEY DO NOT
 ALREADY EXIST WITHIN THE RESIDENCE. IF THE RESIDENCE
 HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE
 A CARBON MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET
 OF EACH ROOM USED FOR SLEEPING. FBC R313
 VERIFY THE KITCHEN COUNTER TOP RECEPTACLES AND BATHROOM
 RECEPTACLES ARE GFCI PROTECTED. NEC 210.8
 INDICATE THAT ALL NEW RECEPTACLES WILL BE TAMPER
 RESISTANT. NEC 406.11
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2012-01-03 Cont ID  
Sent By fmittner Date 2012-01-03 Time 15:25 Rev Time 0.00
Received By fmittner Date 2012-01-03 Time 15:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-02-08 Cont ID  
Sent By rlecky Date 2012-02-08 Time 10:16 Rev Time 0.00
Received By rlecky Date 2012-02-08 Time 10:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-01-24 Cont ID  
Sent By rmcdouga Date 2012-01-24 Time 14:38 Rev Time 0.00
Received By rmcdouga Date 2012-01-03 Time 17:15 Sent To  
Notes
2012-01-09 16:28:38R13
  
2012-01-03 17:15:19MISC 2

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-01-24 Cont ID  
Sent By rmcdouga Date 2012-01-24 Time 14:33 Rev Time 0.00
Received By rmcdouga Date 2012-01-24 Time 14:33 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2012-01-03 Cont ID  
Sent By fmittner Date 2012-01-03 Time 15:25 Rev Time 0.00
Received By fmittner Date 2012-01-03 Time 15:25 Sent To  
Notes
***NONE***