Plan Review Details - Permit 11120607
| Plan Review Stops For Permit 11120607 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-01-23 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-01-23 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-01-23 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-01-06 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-01-06 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-01-05 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2012-01-05 15:42:45 | SEE FD COMMENTS. | | | TO MECHANICAL |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2012-01-17 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-01-17 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-01-17 |
Time |
12:18 |
Sent To |
M |
|
| Notes |
| 2012-01-17 12:32:03 | 601 CLEARWATER PARK | | | PERMIT #11120607 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PER NFPA 72, SMOKE DETECTORS SHALL NOT BE INSTALLED IN | | | UNSPRINKLERED ELEVATOR HOISTWAYS UNLESS THEY ARE | | | INSTALLED TO ACTIVATE SMOKE RELIEF EQUIPMENT. | | | | | | THERE IS AN EXISTING FIRE SHUTTER (WITH FUSIBLE LINK?) | | | ON THE FIRST FLOOR ADJACENT TO THE STAIR. PROVIDE SMOKE | | | DETECTORS ON EACH SIDE OF THE SHUTTER TO ACTIVATE THE | | | SHUTTER. FIRE SHUTTER SHALL ALSO DROP UPON ACTIVATION | | | OF OTHER FIRE ALARM DEVICES. | | | | | | PER LOCAL CODE AMENDMENTS, DUCT SMOKE DETECTORS SHALL | | | INITIATE A GENERAL FIRE ALARM CONDITION. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-12-28 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-12-28 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-12-28 |
Time |
14:16 |
Sent To |
E |
|
| Notes |
| 2011-12-28 14:41:44 | 601 CLEARWATER PARK | | | PERMIT #11120607 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | FIRE ALARM SHEETS 1 & 2 ARE THE SAME SHEET. SUBMIT FIRE | | | ALARM LAYOUT FOR SECOND FLOOR. | | | | | | THERE IS AN EXISTING FIRE SHUTTER (WITH FUSIBLE LINK?) | | | ON THE FIRST FLOOR ADJACENT TO THE STAIR. PROVIDE SMOKE | | | DETECTORS ON EACH SIDE OF THE SHUTTER TO ACTIVATE THE | | | SHUTTER. FIRE SHUTTER SHALL ALSO DROP UPON ACTIVATION | | | OF OTHER FIRE ALARM DEVICES. | | | | | | PER LOCAL CODE AMENDMENTS, DUCT SMOKE DETECTORS SHALL | | | INITIATE A GENERAL FIRE ALARM CONDITION. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-01-23 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-01-23 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-01-10 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2012-01-10 12:47:42 | TO FIRE BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
P |
Date |
2012-01-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-01-06 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-12-27 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2011-12-27 10:09:11 | IN FIRE BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-01-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-01-23 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-01-23 |
Time |
08:57 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2012-01-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-01-06 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-01-06 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2012-01-06 09:43:38 | PASS PROVISO | | | IF THE LAYOUT OF THE FIRST AND SECOND FLOOR ARE NOT THE | | | SAME REVISIONS WILL BE REQUIRED . | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected]. |
|
|
|