| Plan Review Stops For Permit 11120483 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2012-01-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-01-05 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-01-04 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2012-01-05 09:16:18 | PLANS AND PERMIT INDICATE SITE WORK- FIRE UTILITIES | | | ONLY. JW |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2012-02-01 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2012-02-01 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2012-02-01 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2012-02-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-02-22 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-02-22 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2012-02-15 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-02-15 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-02-15 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2012-02-15 10:19:13 | 6501 NORTH JOG ROAD | | | PERMIT #11120483 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | I HAVE SOME MAJOR CONCERNS WITH THE WATER MAIN | | | SUPPLYING THE COMBINED DEMAND OF THE FIRE HYDRANTS AND | | | DOMESTIC WATER: | | | 1) THE FEED TO THE REMOTE FIRE HYDRANT RESULTS IN A | | | DEAD-END MAIN. | | | 2) THE 6-INCH WATER MAIN WOULD SEEM TO BE UNDERSIZED IN | | | SUPPLYING COMBINED FIRE DEMAND AND DOMESTIC DEMAND. | | | 3) THE DOMESTIC WATER PVC PIPE IN THE TRAILERS COULD | | | BECOME DESTROYED IN A FIRE EVENT AND COMPROMISE THE | | | MUCH NEEDED FLOW AND PRESSURE FOR FIRE SUPPRESSION | | | OPERATIONS. | | | | | | I WOULD PREFER TO HAVE THE FIRE MAIN COMPLETELY | | | SEPARATED FROM THE DOMESTIC WATER. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-12-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-12-29 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-12-29 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2011-12-29 14:43:34 | 6501 NORTH JOG ROAD | | | PERMIT #11120483 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | WATER MAINS AND FIRE HYDRANTS SHALL BE INSTALLED, | | | TESTED AND APPROVED PRIOR TO COMMENCING CONSTRUCTION | | | WORK ON ANY STRUCTURE. | | | | | | INDICATE WHAT FLOW AND PRESSURE IS ANTICIPATED TO BE | | | AVAILABLE AT THESE HYDRANTS. | | | | | | AFTER THE MASTER METER, SEPARATE THE FIRE MAIN SO IT IS | | | INDEPENDENT OF THE DOMESTIC WATER SERVICE. PROVIDE AN | | | INDICATING VALVE (PIV OR BACKFLOW PREVENTER) FOR THE | | | FIRE MAIN. INDICATING VALVE(S) SHALL BE SUPERVISED IN | | | THE OPEN POSITION. | | | | | | PER NFPA 24, SECTION 8.7 PROHIBITS USING FIRE HYDRANTS | | | FOR PURPOSES OTHER THAN FIRE-RELATED SERVICES. | | | | | | ON THE EAST SIDE OF JOG ROAD THE PLANS INDICATE | | | ADDITIONAL STORAGE AND TRAILERS, INDICATE THE WATER | | | SUPPLY AND FIRE HYDRANTS THAT WILL BE PROTECTING THIS | | | AREA. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-02-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-02-22 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-02-21 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2012-02-21 17:40:39 | TO WJ DESK (PUT WITH ORIGINAL SUBMITTAL ALREADY ON WJ | | | DESK) | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-02-15 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-02-15 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-02-08 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2012-02-08 13:40:40 | INCOMING SENT TO FIRE. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-02-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-02-03 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-12-19 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2011-12-29 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-12-29 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-12-21 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2011-12-22 12:59:30 | PLAN SHOWS CITE ENGINEERING PIPEING ONLY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2011-12-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-12-28 |
Time |
09:00 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2011-12-27 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|