Plan Review Details - Permit 11120482
Plan Review Stops For Permit 11120482
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-02-13 Cont ID  
Sent By jwitmer Date 2012-02-13 Time 15:39 Rev Time 0.00
Received By jwitmer Date 2012-02-10 Time 15:14 Sent To  
Notes
2012-02-13 15:40:20BUILDING PLAN REVIEW
 PERMIT: 11120482
 ADD: 6501 N JOG RD
 CONT: D. S. EAKINS CONSTRUCTION CORP
 TEL: (561)719-6669
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
  
  
  
 BUILDING PROVISO:
  
 NOTE: APA ENGINEERED WOOD SYSTEMS BULLETIN OCT. 1995
 120 MPH FASTEST MILE = 140 MPH 3 SECOND GUST
  
 2007/09 FBC-B 1609.1.2.
 EXCEPTION # 1)
 WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16
 INCH (11.1 MM) AND A MAXIMUM SPAN OF 8 FEET (2438 MM)
 SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE- AND
 TWO-STORY BUILDINGS. PANELS SHALL BE PRECUT SO THAT
 THEY SHALL BE ATTACHED TO THE FRAMING SURROUNDING THE
 OPENING CONTAINING THE PRODUCT WITH THE GLAZED
 OPENINGS. PANELS SHALL BE PREDRILLED AS REQUIRED FOR
 THE ANCHORAGE METHOD AND ALL REQUIRED HARDWARE SHALL BE
 PROVIDED. ATTACHMENT SHALL BE DESIGNED TO RESIST THE
 COMPONENTS AND CLADDING LOADS DETERMINED IN ACCORDANCE
 WITH THE PROVISIONS OF ASCE 7, WITH PERMANENT
 CORROSION-RESISTANT ATTACHMENT HARDWARE PROVIDED AND
 ANCHORS PERMANENTLY INSTALLED ON THE BUILDING.
 ATTACHMENT IN ACCORDANCE WITH TABLE 1609.1.2, WITH
 PERMANENT CORROSION RESISTANT ATTACHMENT HARDWARE
 PROVIDED AND ANCHORS PERMANENTLY INSTALLED ON THE
 BUILDING IS PERMITTED FOR BUILDINGS WITH A MEAN ROOF
 HEIGHT OF 45 FEET (13 716 MM) OR LESS WHERE WIND SPEEDS
 DO NOT EXCEED 140 MPH (63 M/S)
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-01-04 Cont ID  
Sent By jwitmer Date 2012-01-04 Time 15:50 Rev Time 1.55
Received By jwitmer Date 2012-01-04 Time 15:50 Sent To  
Notes
2012-01-04 16:48:08BUILDING PLAN REVIEW
 PERMIT: 11120482
 ADD: 6501 N JOG RD
 CONT: D. S. EAKINS CONSTRUCTION CORP
 TEL: (561)719-6669
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) DISCREPANCY BETWEEN THE STATE APPROVED SOUTHEAST
 MODULAR MANUFACTURING PLAN (SHEET 2 OF 6) WITH 3920 SQ
 FT AND THE COPIED NOT SEALED FOUNDATION PLAN FROM
 WILLIAM SCOTSMAN PLAN (SHEET 4) FOR 2880 SQ FT. PLEASE
 PROVIDE THE FOUNDATION PLAN THAT MATCHES TO THE
 SOUTHEAST MANUFACTURING PLAN. NOTE THIS IS A SITE
 SPECIFIC ENGINEERING WITCH WILL REQUIRE A ENGINEER SEAL
 AND SIGNATURE.
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE
 DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT.
 FL ADMIN CODE 61G15-23.002 ENGINEERS
  
 2) SHEET A1 RAMP DETAILS IS ALSO NOT SIGNED NOR SEALED
 BY THE DESIGN PROFESSIONAL. PLEASE NOTE THE SHEET A1 IS
 FOR A STRAIGHT RUN RAMP DETAIL WHILE THE STAGING PLAN
 FROM BE & K # 700-C0-020 INDICATES A RAMP WITH A SWITCH
 BACK AND A MID LANDING, PLEASE PROVIDE AN ENGINEERED
 PLAN THAT FITS THIS INSTALATION APPLICATION.
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE
 DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT.
 FL ADMIN CODE 61G15-23.002 ENGINEERS
  
 3) THE PERMIT APPLICATION INDICATES THAT THE
 INSTALATION OF CONSTRUCTION TRAILERS ARE THESE ACTUALLY
 TRAILERS? ARE THEY GOING TO HAVE STORAGE OF
 CONSTRUCTION MATERIALS? OR ARE THEY MANUFACTURED
 BUILDING THAT WILL BE BROUGHT IN ARE FOR BUSINESS USAGE
 TO BE USED FOR THE ADMINISTRATION OF THE PROJECT? THE
 STATE APPROVED PLANS INDICATES THEY
 WERE BUILT WITH THE INTENT OF BUSINESS OFFICES. THIS
 REVIEW WILL BE WITH THE INTENDED USE AS APPROVED BY THE
 STATE, BUSINESS OCCUPANCY.
  
 3A) THE DESIGNER OF RECORD WILL NEED TO CLARIFY IF EACH
 UNIT IS TO BE CONSIDERED A SINGLE BUILDING OF 3920 SQ
 FT OR IF MULTIPLE UNITS TWO OR MORE BUILDINGS ARE GOING
 TO BE CONSIDERED A SINGLE UNIT. PLEASE REVIEW FBC-B
 TABLE 503 FOR A BUSINESS OCCUPANCY A TYPE V-B ALLOWS AN
 AREA OF 9,000 SQ FT THESE UNITS ARE NOT FIRE
 SPRINKLERED NO INCREASE CAN BE TAKEN FOR FIRE
 SPRINKLERS BUT DEPENDING ON THE CONFIGURATION, FRONTAGE
 INCREASES MAY BE TAKEN FBC-B 506.2 WHICH WOULD CREATE A
 LARGER BUILDING.
  
 3B) PLEASE REVIEW TABLE 502 FOR FIRE RESISTANCE RATING
 REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE
 SEPERATION DISTANCE. THE STATE APPROVED PLANS INDICATES
 THAT THERE IS NO FIRE RATING OF THE EXTERIOR WALLS. FOR
 A TYPE V-B BUILDING THE MINIMUM DISTANCE FROM AN
 ASSUMED PROPERTY LINE WOULD BE 10 FEET TO AN ASSUMED
 PROPERTY LINE OR 20 FEET FROM ONE BUILDING TO ANOTHER.
 THE SITE PLAN INDICATES AN AREA WHERE TWO MORE UNITS
 MAY BE BROUGHT IN, THIS MAY NEED TO BE ADDRESSED AT
 THIS TIME AS FAR AS THE SQUARE FOOTAGE THAT WOULD BE
 ALLOWED AND THE ASSUMED PROPERTY LINE BETWEEN UNITS.
 THE 2007 FBC-B CODE COMMENTARY FIGURE 602A HAS MORE
 INFORMATION ON ASSUMED PROPERTY LINES.
  
 4) PLEASE NOTE THAT SHEET 4 IS THE WRONG FOUNDATION
 PLAN THE REQUIREMENT FOR FOUNDATIONS IS OUT OF THE
 2007/09 FBC-B AND THE REQUIREMENTS FOR DEPTH OF
 FOUNDATIONS
 1805.2 IS STILL A MINIMUM OF 12 INCHES BELOW GRADE.
 PLEASE ALSO REVIEW 1805.5.7 FOR PIER FOUNDATIONS AND
 WIND SPEED.
  
 5) PLEASE REVIEW SHEET # 1 OF SITE INSTALLED ITEMS
 PORTABLE FIRE EXTINGUISHERS, STORM SHUTTERS, GUTTERS &
 DOWN SPOUTS AND DRINKING FOUNTAINS.
  
 6) STAGING PLAN DOES NOT PROVIDE DETAIL FOR THE
 HANDICAPPED PARKING AND ACCESS AILSE FBC11-4.6.2(1) &
 11-4.6.4.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2012-02-01 Cont ID  
Sent By mgonzale Date 2012-02-01 Time   Rev Time 0.00
Received By mgonzale Date 2012-02-01 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2012-02-14 Cont ID  
Sent By wjolin Date 2012-02-14 Time 14:16 Rev Time 0.00
Received By wjolin Date 2012-02-14 Time 13:56 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-01-03 Cont ID  
Sent By wjolin Date 2012-01-03 Time 10:24 Rev Time 0.00
Received By wjolin Date 2011-12-29 Time 14:51 Sent To  
Notes
2011-12-29 15:44:456501 NORTH JOG ROAD
 PERMIT #11120482
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SITE COMMENTS
  
 ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO
 THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION
 DEBRIS SHALL BE REMOVED FROM THE SITE DAILY.
  
 PER NFPA 241 - TABLE 4.2.1 (2009 ED.), THE CONSTRUCTION
 TRAILERS SHALL BE SEPARATED FROM EACH OTHER BY A
 DISTANCE OF 30'-60' DEPENDING UPON THE EXPOSING WALL
 LENGTHS. NOTE: SEPARATION DISTANCES CAN BE REDUCED BY
 75% WHEN THE STRUCTURES ARE FULLY SPRINKLERED.
  
 IDENTIFY EACH TRAILER WITH AN ADDRESS OR UNIT
 LETTER/NUMBER. CHARACTERS SHALL BE ATTACHED TO THE
 BUILDING AND BE AT LEAST SIX-INCHES IN HEIGHT WITH
 1-INCH STROKE AND SHALL CONTRAST THE BACKGROUND.
  
 ALL GATES WILL NEED TO BE PROVIDED WITH KNOX KEY
 SWITCHES OR KNOX PADLOCKS TO ALLOW ACCESS TO EMERGENCY
 RESPONDERS. KEY SWITCHES AND PADLOCKS CAN BE ORDERED
 FROM WWW.KNOXBOX.COM.
  
 THE EMERGENCY VEHICLE ACCESS LANE NEAR THE TRAILERS
 SHALL BE MARKED WITH FREESTANDING SIGNS READING, "FIRE
 LANE - NO PARKING BY ORDER OF THE FIRE DEPARTMENT"
 SIGNS SHALL BE 12" X 18" WITH A WHITE BACKGROUND AND
 RED LETTERS AND SHALL BE A MAXIMUM OF SEVEN FEET IN
 HEIGHT TO THE BOTTOM OF THE SIGN. SIGNS SHALL BE WITHIN
 SIGHT OF THE TRAFFIC FLOW AND BE SPACED A MAXIMUM OF 60
 FEET APART.
  
 POST WEATHERPROOF NO SMOKING SIGNS ON ALL CONSTRUCTION
 TRAILERS. SMOKING SHALL BE PERMITTED ONLY DESIGNATED
 AREAS. PROVIDE SAFE RECEPTACLES FOR DISCARDED SMOKING
 MATERIALS.
  
 ACCESS FOR USE OF FIRE DEPARTMENT APPARATUS SHALL BE
 PROVIDED TO THE IMMEDIATE JOB SITE AT THE START OF THE
 PROJECT AND MAINTAINED UNTIL COMPLETION.
  
 WET FIRE HYDRANTS SHALL BE INSTALLED, TESTED AND
 INSPECTED PRIOR TO THE START OF ANY CONSTRUCTION
 ACTIVITIES.
  
 A SUITABLE LOCATION AT THE SITE SHALL BE DESIGNATED AS
 A COMMAND POST AND PROVIDED WITH PLANS, EMERGENCY
 INFORMATION, KEYS, COMMUNICATIONS, AND EQUIPMENT, AS
 NEEDED.
  
 CONSTRUCTION TRAILER COMMENTS
  
 NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK INFORMATION.
  
 IN ADDITION TO THE FLORIDA BUILDING CODE, THE FIRE
 PROTECTION AND LIFE SAFETY DESIGN SHALL CONFORM TO THE
 2010 EDITION OF THE FLORIDA FIRE PREVENTION CODE (2009
 EDITION OF NFPA 1 & NFPA 101 WITH FLORIDA AMENDMENTS).
  
 INDICATE THE LOCATIONS OF ALL STAIRS THAT EGRESS THE
 PLATFORM CONNECTING ALL THE TRAILERS.
  
 PROVIDE TACTILE SIGNAGE AT ALL EXIT DOORS WITH EXIT
 SIGNS.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 INDICATE IF THERE ARE ANY CONFERENCE OR MEETING ROOMS
 THAT WILL BE TREATED AS AN ASSEMBLY OCCUPANCY
 ACCOMPANYING 50 OR MORE PERSONS.
  
 SHEET A1 DOES NOT BEAR THE SIGNATURE/SEAL OF THE DESIGN
 PROFESSIONAL.
  
 NOTE: THE CONSTRUCTION TRAILERS WILL BE TREATED AS
 PERMANENT STRUCTURES AS THEY WILL REMAIN IN PLACE FOR
 MORE THAN 180 DAYS.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-02-16 Cont ID  
Sent By lmartine Date 2012-02-16 Time 11:18 Rev Time 0.00
Received By lmartine Date 2012-02-07 Time 13:35 Sent To  
Notes
2012-02-08 13:35:36INCOMING SENT TO C01. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-02-03 Cont ID  
Sent By shill Date 2012-02-03 Time 08:54 Rev Time 0.00
Received By shill Date 2011-12-19 Time 10:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2012-02-16 Cont ID  
Sent By lmartine Date 2012-02-16 Time 11:17 Rev Time 0.00
Received By lmartine Date 2012-02-16 Time 11:16 Sent To  
Notes
2012-02-16 11:17:49PASS PER ERIC SEE STAMP AND SIGNATURE ON PLANS.

Review Stop Z ZONING
Rev No 1 Status P Date 2011-12-28 Cont ID  
Sent By eschneid Date 2011-12-28 Time 08:58 Rev Time 0.50
Received By eschneid Date 2011-12-27 Time 16:59 Sent To  
Notes
2011-12-28 08:59:10FENCE/GATE REQUIRES SEPARATE PERMIT.