Plan Review Details - Permit 11120079
Plan Review Stops For Permit 11120079
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-02-24 Cont ID  
Sent By rmcdouga Date 2012-02-24 Time 13:40 Rev Time 0.00
Received By rmcdouga Date 2012-02-23 Time 09:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-12-22 Cont ID  
Sent By rmcdouga Date 2011-12-22 Time 17:03 Rev Time 0.00
Received By rmcdouga Date 2011-12-15 Time 13:58 Sent To  
Notes
2011-12-22 16:49:022007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) ON SHEET A.02 AND A.03 THERE IS A SECTION MARK FOR
 SECTION 13 ON A.07. THERE IS NO SECTION 13 ON A.07.
 PLEASE CLARIFY. CITY AMENDMENTS 106.1.1
  
 2) ON SHEET A.02 THERE IS A SECTION THROUGH THE
 CONCRETE STAIRS AT THE GARAGE MARKED 13 ON A.07. THERE
 IS NO SECTION 13 ON A.07. PLEASE CLARIFY. CITY
 AMENDMENTS 106.1.1
  
 3) THE WINDER TREADS ON THE INTERIOR STAIRS ARE
 REQUIRED TO COMPLY WITH FBCR 311.5.3.2 WHICH REQUIRES A
 MINIMUM TREAD DEPTH OF 10" AT A POINT 12" FROM THE SIDE
 WHERE THE TREADS ARE NARROWER AND A MINIMUM TREAD DEPTH
 OF 6" AT ANY POINT.
  
 4) PROVIDE A SECTION THROUGH THE GARAGE APARTMENT.
 SPECIFY THE INSULATION IN THE WALLS, CEILING AND FLOOR.
 CITY AMENDMENTS 106.1.1
  
 5) SHOW COMPLIANCE WITH FBC R309.2 FOR SEPARATION
 REQUIREMENTS BETWEEN GARAGE AND LIVING SPACE.
  
 6) SUBMIT ROOF SCUPPER SIZING CALCULATIONS FOR THE
 GARAGE APARTMENT. SPECIFY THE LOCATIONS AND SIZES OF
 THE PRIMARY AND OVERFLOW SCUPPERS. FBC R903.4
  
 7) SHOW COMPLIANCE WITH FBC R320.7 WHICH REQUIRES
 GUTTERS WITH DOWNSPOUTS WITH OF LESS THAN 6 INCHES
 HORIZONTAL PROJECTION AND DOWNSPOUTS TO DISCHARGE AT
 LEAST ONE FOOT AWAY FROM THE STRUCTURE SIDE WALL.
  
 8) THE COMPONENT AND CLADDING PRESSURES FOR THE WINDOW
 AND DOOR OPENINGS ON SHEETS A.02 AN A.03 OF THE
 ARCHITECTURAL PLANS DO NOT CORRESPOND WITH THE
 STRUCTURAL PLANS. THE PRESSURES ON THE ARCHITECTURAL
 PLANS ARE BASED ON EXPOSURE CATEGORY B AND THE
 STRUCTURAL PLANS ARE BASED ON EXPOSURE C. PLEASE
 CORRECT. FBC R301.2.1
  
 9) SOME OF THE PRODUCT APPROVALS SPECIFIED ON SHEET
 A.01 DO NOT CORRESPOND WITH THE PRODUCT APPROVALS THAT
 WERE SUBMITTED. PLEASE CORRECT. CITY AMENDMENTS 106.1.1
  
 10) THE DESIGN PRESSURES LISTED IN THE PRODUCT
 APPROVALS FOR SOME OF THE DOORS DO NOT MEET THE
 COMPONENT AND CLADDING PRESSURES FOR EXPOSURE C IN WALL
 ZONE 5. FBC R301.2.1 PLEASE REVIEW.
  
 11) THE DOOR AT THE SIDE LOGGIA IS LABELED 2 ON A.02,
 WHICH IS THE OVER HEAD GARAGE DOOR. PLEASE CLARIFY.
 CITY AMENDMENTS 106.1.1
  
 12) SUBMIT TWO SETS OF EVALUATION REPORTS FOR THE SPRAY
 FOAM INSULATION TO SHOW COMPLIANCE WITH FBC R314.
  
 13) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE DOUBLE
 FIXED LITE DOORS AS REQUIRED BY DCA RULE 9N-3.
  
 14) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE
 CASEMENT WINDOWS AS REQUIRED BY DCA RULE 9N-3. THE ONES
 THAT WERE SUBMITTED ARE FOR PROJECTED WINDOWS (AWNING).
  
 15) SPECIFY THE APPROVED ASSEMBLY AND FASTENING OPTION
 FROM THE PRODUCT APPROVAL THAT WILL BE USED TO INSTALL
 THE GAF MODIFIED ROOF SYSTEM. SUBMIT TWO SIGNED AND
 SEALED SETS OF RAS 117 CALCULATIONS FOR THE ENHANCED
 FASTENING OF THE BASE SHEET IN ORDER TO MEET THE HIGHER
 UPLIFT PRESSURES AT THE PERIMETER AND CORNER ROOF
 AREAS. FBC R905.12.3
  
 16) SPECIFY THE ATTACHMENT METHOD AND ATTACHMENT
 RESISTANCE MOMENT FROM THE CONCRETE ROOF TILE PRODUCT
 APPROVAL THAT WILL BE USED TO INSTALL THE TILE.FBC
 R905.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-03-01 Cont ID  
Sent By rlecky Date 2012-03-01 Time 12:27 Rev Time 0.00
Received By rlecky Date 2012-03-01 Time 12:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-01-05 Cont ID  
Sent By rlecky Date 2012-01-05 Time 15:01 Rev Time 0.00
Received By rlecky Date 2012-01-04 Time 17:07 Sent To  
Notes
2012-01-05 15:08:1411120079
 219 AVILA RD.
 RESIDENTIAL ADDITION
  
 ELECTRICAL RISER PLAN IS NOT CLEARLY LEGIBLE. PLEASE
 RESUBMIT. NEC 215.5
 PANEL BOARD FEEDERS ARE UNDERSIZED. MINIMUM #3/0, AND
 #3 REQUIRED. NEC 310.16
 PLEASE LOCATE THE CARBON MONOXIDE ALARMS ON THE PLANS
 IN ACCORDANCE WITH THE MANUFACTURER?S RECOMMENDATIONS.
 PLAN NOTES ARE NOT AN ACCEPTABLE ALTERNATIVE. ADD A
 CARBON MONOXIDE DETECTOR FOR THE 2ND FLOOR BEDROOMS
 INCLUDING THE STUDIO. FBC R313
 IN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN
 ELECTRIC SERVICE. NEC 250.94
 ADDITIONAL RECEPTACLES ARE REQUIRED IN THE FOYER. NEC
 210.52
 AC DISCONNECTS MAY NOT BE BLOCKED BY THE CONDITIONING
 UNITS. NEC 110.26
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
 561-805-6718
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2011-12-19 Cont ID  
Sent By rmcdouga Date 2011-12-19 Time 13:22 Rev Time 0.00
Received By rmcdouga Date 2011-12-19 Time 13:22 Sent To  
Notes
2011-12-19 13:23:48SEPARATE PLANS, PERMIT APPLICATION AND REVIEW IS
 REQUIRED FOR GAS.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2012-01-20 Cont ID  
Sent By fmittner Date 2012-01-20 Time 10:19 Rev Time 0.00
Received By fmittner Date 2012-01-20 Time 10:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-03-08 Cont ID  
Sent By lmartine Date 2012-03-07 Time 13:48 Rev Time 0.00
Received By lmartine Date 2012-02-23 Time 14:10 Sent To  
Notes
2012-02-24 14:11:04SENT TO BIN R27, MULTIPLE REVIEWS WERE REQUIRED.
2012-02-13 16:35:33INCOMING SENT TO R MCDOUGAL'S DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-01-20 Cont ID  
Sent By lmartine Date 2012-01-20 Time 10:47 Rev Time 0.00
Received By lmartine Date 2011-12-05 Time 16:39 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2012-02-21 Cont ID  
Sent By rmcdouga Date 2012-02-21 Time 16:49 Rev Time 0.00
Received By rmcdouga Date 2012-02-21 Time 16:48 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2011-12-19 Cont ID  
Sent By rmcdouga Date 2011-12-19 Time 11:25 Rev Time 0.00
Received By rmcdouga Date 2011-12-19 Time 11:25 Sent To  
Notes
2011-12-19 11:26:28BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION. 233-5025

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-02-23 Cont ID  
Sent By rmcdouga Date 2012-02-23 Time 09:03 Rev Time 0.00
Received By rmcdouga Date 2012-02-23 Time 09:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-12-22 Cont ID  
Sent By rmcdouga Date 2011-12-22 Time 10:22 Rev Time 0.00
Received By rmcdouga Date 2011-12-19 Time 15:18 Sent To  
Notes
2011-12-22 11:01:012007 FBC W/2009 REVISIONS
  
 DENIED BY MECHANICAL
  
 1) THE MECHANICAL PLANS SPECIFY 27,400 BTU FOR A/C UNIT
 #2 IN THE UPSTAIRS AREA WHICH DOES NOT CORRESPOND WITH
 THE MANUAL J CALCULATIONS THAT REQUIRE 43,862 BTU FOR
 SYSTEM #2. PLEASE CORRECT. FBCR M1401.3
  
 2) THE ENERGY CALCULATIONS APPEAR TO HAVE COMBINED THE
 DETACHED GARAGE APARTMENT WITH THE SINGLE FAMILY
 RESIDENCE. PLEASE PROVIDE SEPARATE ENERGY CALCULATIONS
 FOR EACH BUILDING. FBC N1100.0
  
 3) THE GARAGE APARTMENT IS NEW CONSTRUCT AND THE SINGLE
 FAMILY RESIDENCE IS AN ADDITION TO AN EXISTING
 BUILDING. PLEASE INDICATE THIS ON ENERGY CALC. FORMS.
  
 4) THE ADJACENT FLOOR-CEILING ASSEMBLY SEPARATING THE
 GARAGE FROM THE CONDITIONED SPACE ABOVE IS REQUIRED TO
 BE INSULATED. N1105.AB.1
  
 5) SPECIFY THE WATER HEATER SYSTEM FOR THE GARAGE
 APARTMENT. N1112.AB
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-02-22 Cont ID  
Sent By rmcdouga Date 2012-02-22 Time 09:10 Rev Time 0.00
Received By rmcdouga Date 2012-02-21 Time 16:49 Sent To  
Notes
2012-02-22 09:11:49REDLINED PLANS TO ADD WASHING MASHING AND LAUNDRY TUB
 TO FIRST FLOOR OF GUEST STUDIO.

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-12-19 Cont ID  
Sent By rmcdouga Date 2011-12-19 Time 13:24 Rev Time 0.00
Received By rmcdouga Date 2011-12-19 Time 13:24 Sent To  
Notes
2011-12-19 13:54:352007 FBC W/2009 REVISIONS
  
 DENIED BY PLUMBING
  
 1) THE PLUMBING RISER DIAGRAM THAT WAS SUBMITTED IS NOT
 LEGIBLE. THE APPROVED DRAWINGS WILL BE DIGITALLY COPIED
 FOR PUBLIC RECORD. PLEASE SUBMIT 2 SETS OF CLEAR AND
 LEGIBLE RISER DIAGRAMS. CITY AMENDMENTS 106.1.1
  
 2) PROVIDE TWO SETS OF A RISER DIAGRAM FOR THE GARAGE
 APARTMENT. CITY AMENDMENTS 106.3.5.4
  
 3) THE PLUMBING RISER DIAGRAM IS REQUIRED TO MATCH THE
 ARCHITECTURAL PLANS. CITY AMENDMENTS 106.1.1
  
 4) THE VENT SYSTEM SERVING EACH BUILDING DRAIN SHALL
 HAVE AT LEAST ONE VENT PIPE THAT EXTENDS TO THE
 OUTDOORS. FBC P3102.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2012-03-07 Cont ID  
Sent By fmittner Date 2012-03-07 Time 11:43 Rev Time 0.00
Received By fmittner Date 2012-03-07 Time 11:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2012-01-20 Cont ID  
Sent By lfranco Date 2012-01-20 Time 10:19 Rev Time 0.00
Received By fmittner Date 2012-01-20 Time 10:19 Sent To  
Notes
2012-01-20 10:23:07REQUIRES SEPERATE LANDSCAPE PERMIT