Plan Review Details - Permit 11120073
| Plan Review Stops For Permit 11120073 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2013-07-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-07-10 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-07-09 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2013-07-09 15:51:30 | BUILDING PLAN REVIEW | | | PERMIT:11120073 | | | ADD: 700 N CONGRESS | | | CONT: TO BE DETERMINED | | | CONTACT: VIVEK GALAV | | | TEL: (561)644-7416 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | ARCHITECT: REG RICK GONZALEZTEL: 659-2383 | | | STRUCTURAL ENGINEER: ANDREW MORGAN P. E. | | | TEL: 881-8999 | | | BUILDING PLAN REVIEW | | | PERMIT:11120073 | | | ADD: 700 N CONGRESS | | | CONT: TO BE DETERMINED | | | CONTACT: JEFF HALVERSONTEL: (561)644-7416 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | ARCHITECT: REG RICK GONZALEZ | | | TEL: 659-2383 | | | STRUCTURAL ENGINEER: ANDREW MORGAN P. E. | | | TEL: 881-8999 | | | | | | 5TH REVIEW | | | DATE: JULY 09/ 2013 | | | ACTION: PROVISO | | | | | | BUILDING PROVISO: | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL | | | RESULT IN FAILED INSPECTION(S) AND THE ASSESSMENT OF | | | RE-INSPECTION FEE(S). REVISIONS REQUIRE ADDITIONAL | | | REVIEWS WITH ASSOCIATED FEES. | | | | | | 1) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING& FAC | | | RULE 9N-3, PLEASE PROVIDE 2 COPIES OF PRODUCT TESTING | | | REPORTS, MISSING REPORTS ARE AS FOLLOWS: | | | 1A) FIXED GLAZING, STOREFRONT | | | 1B) OPERABLE GLAZING UNITS | | | 1C) MULLIONS, HORIZONTAL AND VERTICAL | | | 1D) GLASS BLOCK | | | 1E) EXTERIOR GLAZED SWING DOORS | | | 1F) EXTERIOR INSULATED METAL SWING DOORS | | | 1G) BI-FOLD APPARATUS BAY DOORS/ WITH TRANSOM | | | 1H) EXTERIOR ROOF WALL ACCESS DOOR/ FRAME (H) | | | 1I) DOUBLE ACCESS PANEL ROOF HATCH, INSULATED -182.6. | | | 1J) WALL LOUVERS | | | 1K) A/C ROOF TOP A/C STANDS | | | 1L) ROOF ASSEMBLIES FLAT ROOF INCLUSIVE OF ROOF TOP | | | INSULATION. | | | 1M) ROOF ASSEMBLIES SLOPED ROOF, METAL ROOF SYSTEMS | | | -266.9 ZONE 3 AND -372.5 ROOF OVERHANGS WITHIN ZONE# 3. | | | 1N) BAHAMA SHUTTERS WITH PRODUCT APPROVAL FOR CLOSED | | | POSITION AND ENGINEERING ANALYSIS FOR SHUTTERS WHEN | | | LEFT IN THE OPEN POSITION IN THE CASE OF A HIGH WIND | | | EVENT. | | | 1O) ROOFTOP EXHAUST FANS | | | | | | 2) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 3) REVISION IS REQUIRED FOR THE ELIMINATION OF STONE | | | VENEER ON EXTERIOR WALL OR COMPLIANCE WITH: | | | 2010 FBC-B 2114.2 CONCRETE BEARING LEDGE. | | | BRICK, STONE OR OTHER VENEER SHALL BE SUPPORTED BY A | | | CONCRETE BEARING LEDGE AT LEAST EQUAL TO THE TOTAL | | | THICKNESS OF THE BRICK, STONE OR OTHER VENEER, WHICH IS | | | POURED INTEGRALLY WITH THE CONCRETE FOUNDATION. NO | | | SUPPLEMENTAL CONCRETE FOUNDATION POURS WHICH WILL | | | CREATE A HIDDEN COLD JOINT SHALL BE USED WITHOUT | | | SUPPLEMENTAL TREATMENT IN THE FOUNDATION UNLESS THERE | | | IS AN APPROVED PHYSICAL BARRIER. AN APPROVED PHYSICAL | | | BARRIER SHALL ALSO BE INSTALLED FROM BELOW THE WALL | | | SILL PLATE OR FIRST BLOCK COURSE HORIZONTALLY TO EMBED | | | IN A MORTAR JOINT. IF MASONRY VENEER EXTENDS BELOW | | | GRADE, A TERMITE PROTECTIVE TREATMENT MUST BE APPLIED | | | TO THE CAVITY CREATED BETWEEN THE VENEER AND THE | | | FOUNDATION, IN LIEU OF A PHYSICAL BARRIER. | | | EXCEPTION: VENEER SUPPORTED BY A SHELF, ANGLE OR LINTEL | | | SECURED TO THE FOUNDATION SIDEWALL IN ACCORDANCE WITH | | | TMS 402/ACI 530/ASCE 5, PROVIDED AT LEAST A 6-INCH (152 | | | MM) CLEAR INSPECTION SPACE OF THE FOUNDATION SIDEWALL | | | EXTERIOR EXISTS BETWEEN THE VENEER AND THE TOP OF ANY | | | SOIL, SOD, MULCH OR OTHER ORGANIC LANDSCAPING | | | COMPONENT, DECK, APRON, PORCH, WALK OR ANY OTHER WORK | | | IMMEDIATELY ADJACENT TO OR ADJOINING THE STRUCTURE. | | | JIM, | | | WE WILL REMOVE THE STONE VENEER FROM FIRE STATION 5 AND | | | REPLACE IT WITH STUCCO. | | | THANKS. | | | VIVEK | | | ----- FORWARDED BY VIVEK GALAV/WESTPALM ON 06/18/2013 | | | 02:47 PM ----- | | | FROM: VINCENT KAFER | | | TO: "[email protected]" | | | DATE: 06/18/2013 11:07 AM | | | SUBJECT: FS#5-EOC PERMITTING | | | CAN YOU PLEASE PROVIDE A LETTER TO JIM WIETMER | | | (BUILDING DEPARTMENT) STATING THAT THE CITY HAS DECIDED | | | REMOVING THE STONE VENEER AND REPLACING IT PER STUCCO? | | | THANKS | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2013-06-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-06-17 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-06-17 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2013-06-17 14:30:31 | BUILDING PLAN REVIEW | | | PERMIT:11120073 | | | ADD: 700 N CONGRESS | | | CONT: TO BE DETERMINED | | | CONTACT: VIVEK GALAV | | | TEL: (561)644-7416 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | ARCHITECT: REG RICK GONZALEZTEL: 659-2383 | | | STRUCTURAL ENGINEER: ANDREW MORGAN P. E. | | | TEL: 881-8999 | | | BUILDING PLAN REVIEW | | | PERMIT:11120073 | | | ADD: 700 N CONGRESS | | | CONT: TO BE DETERMINED | | | CONTACT: JEFF HALVERSONTEL: (561)644-7416 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | ARCHITECT: REG RICK GONZALEZ | | | TEL: 659-2383 | | | STRUCTURAL ENGINEER: ANDREW MORGAN P. E. | | | TEL: 881-8999 | | | | | | 5TH REVIEW | | | DATE: JULY 09/ 2013 | | | ACTION: PROVISO | | | | | | BUILDING PROVISO: | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL | | | RESULT IN FAILED INSPECTION(S) AND THE ASSESSMENT OF | | | RE-INSPECTION FEE(S). REVISIONS REQUIRE ADDITIONAL | | | REVIEWS WITH ASSOCIATED FEES. | | | | | | 1) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING& FAC | | | RULE 9N-3, PLEASE PROVIDE 2 COPIES OF PRODUCT TESTING | | | REPORTS, MISSING REPORTS ARE AS FOLLOWS: | | | 1A) FIXED GLAZING, STOREFRONT | | | 1B) OPERABLE GLAZING UNITS | | | 1C) MULLIONS, HORIZONTAL AND VERTICAL | | | 1D) GLASS BLOCK | | | 1E) EXTERIOR GLAZED SWING DOORS | | | 1F) EXTERIOR INSULATED METAL SWING DOORS | | | 1G) BI-FOLD APPARATUS BAY DOORS/ WITH TRANSOM | | | 1H) EXTERIOR ROOF WALL ACCESS DOOR/ FRAME (H) | | | 1I) DOUBLE ACCESS PANEL ROOF HATCH, INSULATED -182.6. | | | 1J) WALL LOUVERS | | | 1K) A/C ROOF TOP A/C STANDS | | | 1L) ROOF ASSEMBLIES FLAT ROOF INCLUSIVE OF ROOF TOP | | | INSULATION. | | | 1M) ROOF ASSEMBLIES SLOPED ROOF, METAL ROOF SYSTEMS | | | -266.9 ZONE 3 AND -372.5 ROOF OVERHANGS WITHIN ZONE# 3. | | | 1N) BAHAMA SHUTTERS WITH PRODUCT APPROVAL FOR CLOSED | | | POSITION AND ENGINEERING ANALYSIS FOR SHUTTERS WHEN | | | LEFT IN THE OPEN POSITION IN THE CASE OF A HIGH WIND | | | EVENT. | | | 1O) ROOFTOP EXHAUST FANS | | | | | | 2) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 3) REVISION IS REQUIRED FOR THE DELETION OF STONE | | | VENEER ON EXTERIOR WALL OR COMPLIANCE WITH: | | | 2010 FBC-B 2114.2 CONCRETE BEARING LEDGE. | | | BRICK, STONE OR OTHER VENEER SHALL BE SUPPORTED BY A | | | CONCRETE BEARING LEDGE AT LEAST EQUAL TO THE TOTAL | | | THICKNESS OF THE BRICK, STONE OR OTHER VENEER, WHICH IS | | | POURED INTEGRALLY WITH THE CONCRETE FOUNDATION. NO | | | SUPPLEMENTAL CONCRETE FOUNDATION POURS WHICH WILL | | | CREATE A HIDDEN COLD JOINT SHALL BE USED WITHOUT | | | SUPPLEMENTAL TREATMENT IN THE FOUNDATION UNLESS THERE | | | IS AN APPROVED PHYSICAL BARRIER. AN APPROVED PHYSICAL | | | BARRIER SHALL ALSO BE INSTALLED FROM BELOW THE WALL | | | SILL PLATE OR FIRST BLOCK COURSE HORIZONTALLY TO EMBED | | | IN A MORTAR JOINT. IF MASONRY VENEER EXTENDS BELOW | | | GRADE, A TERMITE PROTECTIVE TREATMENT MUST BE APPLIED | | | TO THE CAVITY CREATED BETWEEN THE VENEER AND THE | | | FOUNDATION, IN LIEU OF A PHYSICAL BARRIER. | | | EXCEPTION: VENEER SUPPORTED BY A SHELF, ANGLE OR LINTEL | | | SECURED TO THE FOUNDATION SIDEWALL IN ACCORDANCE WITH | | | TMS 402/ACI 530/ASCE 5, PROVIDED AT LEAST A 6-INCH (152 | | | MM) CLEAR INSPECTION SPACE OF THE FOUNDATION SIDEWALL | | | EXTERIOR EXISTS BETWEEN THE VENEER AND THE TOP OF ANY | | | SOIL, SOD, MULCH OR OTHER ORGANIC LANDSCAPING | | | COMPONENT, DECK, APRON, PORCH, WALK OR ANY OTHER WORK | | | IMMEDIATELY ADJACENT TO OR ADJOINING THE STRUCTURE. | | | JIM, | | | WE WILL REMOVE THE STONE VENEER FROM FIRE STATION 5 AND | | | REPLACE IT WITH STUCCO. | | | THANKS. | | | VIVEK | | | ----- FORWARDED BY VIVEK GALAV/WESTPALM ON 06/18/2013 | | | 02:47 PM ----- | | | FROM: VINCENT KAFER | | | TO: "[email protected]" | | | DATE: 06/18/2013 11:07 AM | | | SUBJECT: FS#5-EOC PERMITTING | | | CAN YOU PLEASE PROVIDE A LETTER TO JIM WIETMER | | | (BUILDING DEPARTMENT) STATING THAT THE CITY HAS DECIDED | | | REMOVING THE STONE VENEER AND REPLACING IT PER STUCCO? | | | THANKS | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2013-05-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-05-16 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-05-16 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2013-05-16 09:35:57 | BUILDING PLAN REVIEW | | | PERMIT:11120073 | | | ADD: 700 N CONGRESS | | | CONT: TO BE DETERMINED | | | CONTACT: VIVEK GALAV | | | TEL: (561)644-7416 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | ARCHITECT: REG RICK GONZALEZ | | | TEL: 659-2383 | | | STRUCTURAL ENGINEER: ANDREW MORGAN P. E. | | | TEL: 881-8999 | | | | | | 2ND REVIEW PLANS DATED 06/08/2012 | | | | | | ACTION: DENIED | | | | | | BUILDING PLAN REVIEW | | | PERMIT:11120073 | | | ADD: 700 N CONGRESS | | | CONT: TO BE DETERMINED | | | CONTACT: JEFF HALVERSON | | | TEL: (561)644-7416 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | ARCHITECT: REG RICK GONZALEZ | | | TEL: 659-2383 | | | STRUCTURAL ENGINEER: ANDREW MORGAN P. E. | | | TEL: 881-8999 | | | | | | 3RD REVIEW | | | | | | ACTION: DENIED | | | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) ANOTHER ISSUE THAT VINCENT DIDN'T AGREE WITH WAS: | | | SHEET A-4.11 STONE VENEER MISSING THE CONCRETE BEARING | | | EDGE. 2114.2 CONCRETE BEARING LEDGE. BRICK, STONE OR | | | OTHER VENEER SHALL BE SUPPORTED BY A CONCRETE-BEARING | | | LEDGE AT LEAST EQUAL TO THE TOTAL THICKNESS OF THE | | | BRICK, STONE OR OTHER VENEER, WHICH IS POURED | | | INTEGRALLY WITH THE CONCRETE FOUNDATION. NO | | | SUPPLEMENTAL CONCRETE FOUNDATION POURS WHICH WILL | | | CREATE A HIDDEN COLD JOINT SHALL BE USED WITHOUT | | | SUPPLEMENTAL TREATMENT IN THE FOUNDATION UNLESS THERE | | | IS AN APPROVED PHYSICAL BARRIER. AN APPROVED PHYSICAL | | | BARRIER SHALL ALSO BE INSTALLED FROM BELOW THE WALL | | | SILL PLATE OR FIRST BLOCK COURSE HORIZONTALLY TO EMBED | | | IN A MORTAR JOINT. IF MASONRY VENEER EXTENDS BELOW | | | GRADE, A TERMITE PROTECTIVE TREATMENT MUST BE APPLIED | | | TO THE CAVITY CREATED BETWEEN THE VENEER AND THE | | | FOUNDATION, IN LIEU OF A PHYSICAL BARRIER. | | | EXCEPTION: VENEER SUPPORTED BY A SHELF, ANGLE OR LINTEL | | | SECURED TO THE FOUNDATION SIDEWALL IN ACCORDANCE WITH | | | ACI 530/ASCE 5/TMS 402, PROVIDED AT LEAST A 6-INCH (152 | | | MM) CLEAR INSPECTION SPACE OF THE FOUNDATION SIDEWALL | | | EXTERIOR EXIST BETWEEN THE VENEER AND THE TOP OF ANY | | | SOIL, SOD, MULCH OR OTHER ORGANIC LANDSCAPING | | | COMPONENT, DECK, APRON, PORCH, WALK OR ANY OTHER WORK | | | IMMEDIATELY ADJACENT TO OR ADJOINING THE STRUCTURE. | | | | | | | | | 3) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING& FAC | | | RULE 9N-3, PLEASE PROVIDE 2 COPIES OF PRODUCT TESTING | | | REPORTS, MISSING REPORTS ARE AS FOLLOWS: | | | 3A) FIXED GLAZING, STOREFRONT | | | 3B) OPERABLE GLAZING UNITS | | | 3C) MULLIONS, HORIZONTAL AND VERTICAL | | | 3D) GLASS BLOCK | | | 3E) EXTERIOR GLAZED SWING DOORS | | | 3F) EXTERIOR INSULATED METAL SWING DOORS | | | 3G) BI-FOLD APPARATUS BAY DOORS/ WITH TRANSOM | | | 3H) EXTERIOR ROOF WALL ACCESS DOOR/ FRAME (H) | | | 3I) DOUBLE ACCESS PANEL ROOF HATCH, INSULATED -182.6. | | | 3J) WALL LOUVERS | | | 3K) A/C ROOF TOP A/C STANDS | | | 3L) ROOF ASSEMBLIES FLAT ROOF INCLUSIVE OF ROOF TOP | | | INSULATION. | | | 3M) ROOF ASSEMBLIES SLOPED ROOF, METAL ROOF SYSTEMS | | | -266.9 ZONE 3 AND -372.5 ROOF OVERHANGS WITHIN ZONE# 3. | | | 3N) BAHAMA SHUTTERS WITH PRODUCT APPROVAL FOR CLOSED | | | POSITION AND ENGINEERING ANALYSIS FOR SHUTTERS WHEN | | | LEFT IN THE OPEN POSITION IN THE CASE OF A HIGH WIND | | | EVENT. | | | 3O) ROOFTOP EXHAUST FANS | | | | | | VIVEK, VINCENT IS GOING TO LOOK AT SOME TYPE OF ADHERED | | | SYSTEMS THAT WILL GIVE US THE SAME RESULT AS THE | | | CONCRETE LEDGE THAT ACTS AS A TERMITE BARRIER.. | | | | | | 4) WE HAVE THE OTHER ISSUE AS TO WIND SPEED THAT THE | | | ENGINEER OF RECORD IS CREATING A LETTER INDICATING WHY | | | HE HAS DESIGNED THE BUILDING FOR A CAT 5 HURRICANE, IS | | | THIS DESIGN A STRONGER DESIGN THAN THE MINIMUM CODE. | | | DOES HE TAKE A DERATING FACTOR OF 0.77 FOR A BUILDINGS | | | RISK CATEGORY I VERSES A 1.15 REQUIRED FOR A BUILDING | | | RISK CATEGORY IV ??? | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-06-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-06-11 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-06-08 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2012-06-11 08:15:01 | BUILDING PLAN REVIEW | | | PERMIT:11120073 | | | ADD: 700 N CONGRESS | | | CONT: TO BE DETERMINED | | | CONTACT: JEFF HALVERSON | | | TEL: (561)644-7416 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | ARCHITECT: REG RICK GONZALEZ | | | TEL: 659-2383 | | | STRUCTURAL ENGINEER: ANDREW MORGAN P. E. | | | TEL: 881-8999 | | | | | | 2ND REVIEW PLANS DATED 06/08/2012 | | | | | | ACTION: DENIED | | | | | | 1) 106.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS: | | | 1A)COMPLIED. 106.3.5.(1) ENERGY CALCULATIONS- | | | MECHANICAL | | | | | | 1B) 2ND REQUEST. 106.3.5(8) STRUCTURAL REQUIREMENTS | | | SHALL INCLUDE, SOIL CONDITIONS/ANALYSIS | | | | | | 1C) COMPLIED. | | | | | | 1D) SPECIAL SYSTEMS: LIFTS- DUMBWAITERS | | | | | | 1E) SHEET S-01 FOUNDATION NOTE# 1 REQUIRES A FOUNDATION | | | REPORT. | | | 1802.2.1 QUESTIONABLE SOIL. WHERE THE CLASSIFICATION, | | | STRENGTH OR COMPRESSIBILITY OF THE SOIL ARE IN DOUBT OR | | | WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED | | | IN THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL | | | REQUIRE THAT THE NECESSARY INVESTIGATION BE MADE. SUCH | | | INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF | | | SECTIONS 1802.4 THROUGH 1802.6. | | | | | | 2) S-02 WIND DESIGN CRITERIA: | | | 2A) THE STRUCTURAL PLANS S02 INDICATE A DESIGN TO 195 | | | MPH. THE ASCE 7-05 ONLY GO TO 170 MPH, 3 SECOND | | | GUST.THE ASCE 7-10 WILL NOT TAKE EFFECT UNTIL MARCH | | | 15/2012 WHEN THE NEW 2010 FBC GOES INTO EFFECT. PLEASE | | | ALSO NOTE THE BUILDING CATEGORY IS APPARENTLY A II | | | SINCE THE IMPORTANCE FACTOR IS ONLY FIGURED TO BE 1.0. | | | THIS BUILDING IS TO BE CONSIDERED THE EOC FOR THE CITY | | | . PLEASE REVIEW ASCE 7-05 TABLE 1-1, THE BUILDING | | | CATEGORY SHOULD BE A BUILDING CATEGORY IV WITH A | | | IMPORTANCE FACTOR OF 1.15. FIRE, RESCUE, DESIGNATED | | | EMERGENCY PREPAREDNESS COMMUNICATIONS OPERATIONS | | | CENTERS THAT ARE TO BE DESIGNED AS ESSENTIAL | | | FACILITIES. | | | | | | 2B) PLEASE ALSO PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | NEW STRUCTURE. | | | HEIGHT, BUILDING. THE VERTICAL DISTANCE FROM GRADE | | | PLANE TO THE AVERAGE HEIGHT OF THE HIGHEST ROOF | | | SURFACE. 502.1. THIS WILL DETERMINE WHICH MULTIPLIERS | | | TO BE USED IN CONSIDERING PRESSURES. | | | | | | 3) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING& FAC | | | RULE 9B-72, PLEASE PROVIDE 2 COPIES OF PRODUCT TESTING | | | REPORTS, MISSING REPORTS ARE AS FOLLOWS: | | | 3A) FIXED GLAZING, STOREFRONT | | | 3B) OPERABLE GLAZING UNITS | | | 3C) MULLIONS, HORIZONTAL AND VERTICAL | | | 3D) GLASS BLOCK | | | 3E) EXTERIOR GLAZED SWING DOORS | | | 3F) EXTERIOR INSULATED METAL SWING DOORS | | | 3G) BI-FOLD APPARATUS BAY DOORS/ WITH TRANSOM | | | 3H) EXTERIOR ROOF WALL ACCESS DOOR/ FRAME (H) | | | 3I) DOUBLE ACCESS PANEL ROOF HATCH, INSULATED -182.6. | | | 3J) WALL LOUVERS | | | 3K) A/C ROOF TOP A/C STANDS | | | 3L) ROOF ASSEMBLIES FLAT ROOF INCLUSIVE OF ROOF TOP | | | INSULATION. | | | 3M) ROOF ASSEMBLIES SLOPED ROOF, METAL ROOF SYSTEMS | | | -266.9 ZONE 3 AND -372.5 ROOF OVERHANGS WITHIN ZONE# 3. | | | 3N) BAHAMA SHUTTERS WITH PRODUCT APPROVAL FOR CLOSED | | | POSITION AND ENGINEERING ANALYSIS FOR SHUTTERS WHEN | | | LEFT IN THE OPEN POSITION IN THE CASE OF A HIGH WIND | | | EVENT. | | | 3O) ROOFTOP EXHAUST FANS | | | | | | 4) PLEASE THE CONTRACTOR DOES HAVE THE OPTION TO SUBMIT | | | THESE PRODUCT APPROVALS AT A LATER DATE (AFTER PERMIT | | | ISSUANCE), TO DO SO WILL BE CONSIDERED A REVISION ( FOR | | | EACH APPROVAL) AND REQUIRE ADDITIONAL FEES AND REVIEWS. | | | 106.3.5.1.1(8) STRUCTURAL REQUIREMENTS SHALL INCLUDE | | | BUILDING ENVELOPE. | | | | | | 5) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 6) PLEASE NOTE, 1609.1.4 PROTECTION OF OPENINGS IN | | | WIND-BORNE DEBRIS REGIONS, EXTERIOR GLAZING THAT | | | RECEIVES POSITIVE PRESSURE IN THE LOWER 60 FEET (18.3 | | | M) IN BUILDINGS SHALL BE ASSUMED TO BE OPENINGS AND THE | | | BALANCE OF GLAZED OPENINGS IN THE REST OF THE BUILDING | | | SHALL BE ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT | | | RECEIVES POSITIVE PRESSURE IS IMPACT RESISTANT OR | | | PROTECTED WITH AN IMPACT RESISTANT COVERING MEETING THE | | | REQUIREMENTS OF SSTD 12, ASTM E 1886 AND ASTM E 1996, | | | OR MIAMI-DADE TAS 201, 202 AND 203 REFERENCED THEREIN | | | AS FOLLOWS: 1. GLAZED OPENINGS LOCATED WITHIN 30 FEET | | | (9.1 M) OF GRADE SHALL MEET THE REQUIREMENTS OF THE | | | LARGE MISSILE TEST. | | | ASTM E 1996 REQUIREMENTS DO HAVE A MORE RESTRICTIVE | | | REQUIREMENT FOR LARGE MISSILE IMPACT TESTING | | | REQUIREMENT FOR ESSENTIAL FACILITIES OF IMPACT SPEED OF | | | 80 FPS WITH A 9.0 LB 2X4 MISSILE. | | | | | | 7)SHEET M-1.03, ALL ROOF TOP EQUIPMENT SHALL PROVIDE | | | DOCUMENTATION HOW THE EXTERIOR CABINET OR ENVELOPE OF | | | APPLIANCE MEETS THE WIND LOAD REQUIREMENTS OF 1609. | | | WIND RESISTANCE. MECHANICAL EQUIPMENT, APPLIANCES AND | | | SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED AND | | | INSTALLED TO RESIST WIND PRESSURES ON THE EQUIPMENT AND | | | THE SUPPORTS AS DETERMINED IN ACCORDANCE WITH THE | | | FLORIDA BUILDING CODE, BUILDING. 301.12 FBC MECHANICAL/ | | | 2007 | | | | | | 8) SHEET A-4.01 NOTES FOR THE ROOFING ASSEMBLIES, NOTE | | | 601 INDICATES ROOF SHEATHING REFER TO STRUCTURALS, | | | NEITHER SHEET S01 STEEL DECK NOR STEEL JOIST PROVIDE | | | THE TYPE OF ROOF SHEATHNG TO BE USED ON THE GALVANIZED | | | DECKING. S31 NOTES FOR ROOF DECKING ALSO FAIL TO | | | PROVIDE THE TYPE OF ROOF SHEATHING AND OR WALL | | | SHEATHING TO BE INSTALLED.THIS IS A TYPE IIB BUILDING, | | | NON-COMBUSTIBLE SHEATHING TO BE INSTALLED. | | | | | | 9) SHEET A-4.01 NOTE 908 INDICATES THE USE OF A | | | ALUMINUM ACCESS FLOOR SYSTEM, 24"X24" PANELS, 12 INCH | | | HIGH PEDESTALS. PLEASE PROVIDE MANUFACTURERS SPEC SHEET | | | FOR THIS PRODUCT AND ALLOWABLE LIVE LOADS TABLE 1607.1, | | | COMPUTER ROOMS SHALL BE DESIGNED FOR HEAVIER LOADS | | | BASED ON THE ANTICIPATED OCCUPANCY. TYPE OF MATERIALS | | | THIS PRODUCT IS MANUFACTURED 805.1. THE COMMAND CENTER | | | INDICATES THE USE OFTHIS PRODUCT PLEASE PROVIDE WALL | | | DETAIL BETWEEN THE COMMAND CENTER AND R-2 ADJACENT | | | OCCUPANCY. | | | | | | 10) SHEET A-4.11 DETAIL#1 & 3A INDICATES THE USE OF | | | STONE VENEER, PLEASE PROVIDE ATTACHMENT METHODS. | | | 1405.5 ANCHORED MASONRY VENEER. ANCHORED MASONRY VENEER | | | SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1405.5, | | | 1405.6, 1405.7 AND 1405.8 AND SECTIONS 6.1 AND 6.2 OF | | | ACI 530/ASCE 5/TMS 402. | | | | | | 11)3) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING& FAC | | | RULE 9B-72, PLEASE PROVIDE 2 COPIES OF PRODUCT TESTING | | | REPORTS, MISSING REPORTS ARE AS FOLLOWS: | | | 3A) FIXED GLAZING, STOREFRONT | | | 3B) OPERABLE GLAZING UNITS | | | 3C) MULLIONS, HORIZONTAL AND VERTICAL | | | 3D) GLASS BLOCK | | | 3E) EXTERIOR GLAZED SWING DOORS | | | 3F) EXTERIOR INSULATED METAL SWING DOORS | | | 3G) BI-FOLD APPARATUS BAY DOORS/ WITH TRANSOM | | | 3H) EXTERIOR ROOF WALL ACCESS DOOR/ FRAME (H) | | | 3I) DOUBLE ACCESS PANEL ROOF HATCH, INSULATED -182.6. | | | 3J) WALL LOUVERS | | | 3K) A/C ROOF TOP A/C STANDS | | | 3L) ROOF ASSEMBLIES FLAT ROOF INCLUSIVE OF ROOF TOP | | | INSULATION. | | | 3M) ROOF ASSEMBLIES SLOPED ROOF, METAL ROOF SYSTEMS | | | -266.9 ZONE 3 AND -372.5 ROOF OVERHANGS WITHIN ZONE# 3. | | | 3N) BAHAMA SHUTTERS WITH PRODUCT APPROVAL FOR CLOSED | | | POSITION AND ENGINEERING ANALYSIS FOR SHUTTERS WHEN | | | LEFT IN THE OPEN POSITION IN THE CASE OF A HIGH WIND | | | EVENT. | | | 3O) ROOFTOP EXHAUST FA | | | | | | EXCEPTION: VENEER SUPPORTED BY A SHELF, ANGLE OR LINTEL | | | SECURED TO THE FOUNDATION SIDEWALL IN ACCORDANCE WITH | | | ACI 530/ASCE 5/TMS 402, PROVIDED AT LEAST A 6-INCH (152 | | | MM) CLEAR INSPECTION SPACE OF THE FOUNDATION SIDEWALL | | | EXTERIOR EXIST BETWEEN THE VENEER AND THE TOP OF ANY | | | SOIL, SOD, MULCH OR OTHER ORGANIC LANDSCAPING | | | COMPONENT, DECK, APRON, PORCH, WALK OR ANY OTHER WORK | | | IMMEDIATELY ADJACENT TO OR ADJOINING THE STRUCTURE. | | | | | | 12) COMPLIED. | | | | | | 13) LS1 THE PLANS INDICATE STORAGE ROOMS 1.18 & 2.03 | | | BOTH TO BE STORAGE ROOMS THE PLANS DO NOT PROVIDE ANY | | | WALL TYPE DESIGNATION FOR THE RESISTING OF SMOKE.SEE | | | SECTION 508.2.2.1 & TABLE 508.2. | | | | | | 14) LS1 THE PLANS ALSO INDICATES THE ELEVATOR ENTRY IN | | | THE LOBBY DIRECTLY ACROSS FROM THE STAIR TOWER 3.51 | | | WHICH EMPTIES INTO THE LOBBY WHICH IS A CONTINUATION OF | | | THE STAIRWAY. | | | FBC-B 1020.1.1 ELEVATORS SHALL NOT OPEN INTO AN EXIT | | | ENCLOSURE. WHERE INTERIOR EXIT ENCLOSURES ARE EXTENDED | | | TO THE EXTERIOR OF A BUILDING BY AN EXIT PASSAGEWAY, | | | THE DOOR ASSEMBLY FROM THE EXIT ENCLOSURE TO THE EXIT | | | PASSAGEWAY SHALL BE PROTECTED BY A FIRE DOOR ASSEMBLY | | | CONFORMING TO THE REQUIREMENTS IN SECTION 715.4. FIRE | | | DOOR ASSEMBLIES IN EXIT ENCLOSURES SHALL COMPLY WITH | | | SECTION 715.4.4. IF THIS EXIT IS PART OF AN EXIT | | | PASSAGE WAY NO FURNITURE CAN BE IN THIS AREA. FBC | | | 1021.1. | | | | | | 15) LS 2 ROOM # 3.11, 3.14.3.15 & 3.61ARE SLEEPING | | | ROOMS BUT NO OCCUPANCY SEPERATION WALLS THE TOTAL | | | SQUARE FT FOR THESE ROOMS IS 1172 WHICH IS OVER THE 10% | | | OF 10,213 SQ FT LISTED ON LS-2. PLEASE SEE FBC-B TABLE | | | 508.3.3. 2007 FBC-B CODE COMMENTARY LIST FIRE STATION | | | SLEEPING ROOMS AS DORMATORIES. IN BOTH CASES LS1 & LS2 | | | BOTH FLOORS WILL NEED TO SHOW FIRE RATED CORRIDORS IN | | | ACCORDANCE WITH FBC-B TABLE 1017.1 AND FIRE RATED DOORS | | | THROUGH INTERVENING ROOMS AND CORRIDORS IN ACCORDANCE | | | WITH FBC-B TABLE 715.4-DOORS AND 715.5-WINDOWS. | | | | | | 16) LS-2 THE MECHANICAL ROOM # 3.24 IS MISSING A PAIR | | | OF EXTERIOR DOUBLE DOORS, DO THEY LEED ONTO THE ROOF | | | DECK? FBC-B 1609. | | | | | | 17) (A)SHEET A-1.01, A-1.02 & A1.03 BOTH INDICATE WALL | | | TAG TYPES, PLANS INDICATE A WALL TAG TYPE S5 NO FIRE | | | RATING IN LOCATIONS OF RESTROOMS WHERE THESE ROOMS | | | REQUIRE A FIRE RATING BETWEEN OCCUPANCIES, AND OR FIRE | | | RATED CORRIDORS. PLEASE UPDATE WALL TYPE TAGS FOR | | | IDENTIFICATION FOR FIRE RATED WALLS, SMOKE RATED WALLS. | | | PLEASE USE UL, GYPSUM OR OTHER NATIONALLY APPROVED | | | SYSTEM. 106.3.5.1.1(4), TABLE508.3.3.4 AND 708.1. | | | | | | | | | 18)(A) SHEET A6.01 WILL NEED TO BE UPDATED ONCE THE | | | WALL SCHEDULE IS UPDATED TO SHOW ALL RATED WALLS AND | | | PENETRATIONS FBC-B TABLE 715.4. | | | | | | 18)(B) SHEET A1.01 INDICATES A CORRIDOR 1.02 WHICH | | | LEADS OUT INTO THE FIRE BAYS THERE IS ONLY 1'-5" | | | BETWEEN THE WALL AND DOORS WHEN IN THE OPEN POSITION. | | | | | | 19) LS-2 NOR A-1.2 INDICATE THE USAGE OF THE MEZZANINE | | | THE FORMER PERMIT 10030034 SHEET A-1.02 INDICATED THIS | | | TO BE A TRAINING AREA. | | | L.S. 2 MEZZANINE AREA, PLANS INDICATE THIS TO BE A | | | TRAINING AREA 869/15= 58 OCCUPANTS, | | | TABLE 1015.1 REQUIRES 2 EXITS. | | | | | | 20) L. S. 2 MEZZANINE LEVEL DOES NOT SHOW VERTICAL | | | ACCESSIBILITY REQUIREMENTS 11-4.1.3(5). | | | 11-1.3 THIS CODE ESTABLISHES STANDARDS FOR | | | ACCESSIBILITY TO PLACES OF PUBLIC ACCOMMODATION AND | | | COMMERCIAL FACILITIES BY INDIVIDUALS WITH DISABILITIES. | | | THIS CODE SHALL ALSO APPLY: TO STATE AND LOCAL | | | GOVERNMENT FACILITIES PURSUANT TO SECTION 553.503, | | | FLORIDA STATUTES; | | | CHAPTER 11 | | | REQUEST FOR WAIVER FROM ACCESSIBILITY REQUIREMENTS | | | CHAPTER 553, | | | PART V, FLORIDA STATUTES AUGUST 1999 | | | PART C THIS APPLICATION IS AVAILABLE IN ELECTRONIC | | | FORMAT AT: | | | HTTP://WWW.DCA.STATE.FL.US/FHCD/FBC/ACCESS_WAIVER/WAIVE | | | RAP.HTM. | | | | | | 21) A-6.01/ A-7.01 & A-4.11 THE MAIN LOBBY IS TO BE | | | CONSIDERED A 2 STORY ATRIUM, THE GLAZING WITHIN THIS | | | AREA STORE FRONT FIRST FLOOR AND SECOND FLOOR WILL NEED | | | TO MEET THE REQUIREMENTS FOR A 1 HOUR RATED WALL. | | | A-7.01 WINDOW SCHEDULE DOES NOT INDICATE ANY FIRE RATED | | | WINDOWS. PLEASE ALSO REVIEW EXCEPTION UNDER 404.5 FOR | | | WATER CURTAIN. NOTE THERE CAN BE NO INTERMEDIATE | | | HORIZONTAL MULLIONS WITH USE OF WATER CURTAIN. SHEET | | | A-1.02 DOES HAVE A CUT SECTION THROUGH THE LOBBY DETAIL | | | 2/A4.11 WHICH IS FOR THE EXTERIOR WALL? | | | | | | 22) PLEASE PROVIDE COMPLIANCE WITH: FL S 255.2575 | | | ENERGY-EFFICIENT & SUSTAINABLE BUILDINGS. PLANS THAT | | | ARE COMMENCED AFTER JULY1, 2008 SHALL BE CONSTRUCTED TO | | | MEET THE UNITED STATES GREEN BUILDING COUNCIL (USGBC), | | | LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN (LEED) | | | RATING SYSTEM, THE GREEN BUILDING INITIATIVE'S GREEN | | | GLOBAL RATING SYSTEM, THE FLORIDA GREEN BUILDING | | | COALITION STANDARDS, OR A NATIONALLY RECOGNIZED, HIGH | | | PERFORMANCE GREEN BUILDING RATING SYSTEM AS APPROVED BY | | | THE DEPARTMENT OF MANAGEMENT SERVICES. | | | | | | 23) 08/02/2012 CITY WILL NOT REQUIRE RESIDENT INSPECTOR | | | FOR THIS PROJECT WE WILL DO OUR OWN INSPECTIONS. JW. | | | WEST PALM BEACH ADMINISTRATIVE CODE 109.3.7 BUILDINGS | | | REQUIRING SPECIAL ONSITE INSPECTORS: | | | 1) TYPE I OR TYPE II CONSTRUCTION | | | 5) BUILDINGS WITH AREAS GREATER THAN 20,000 SQ FT | | | | | | DID NOT SUBMIT!!!!!!!!!!!!!!!!!!!!!!!!! | | | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | JIM WITMER C. B. O. | | | COMMERCIAL COMBINATION PLAN REVIEW | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | | CUSTOMER SERVICE SURVEY AT: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-12-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-12-09 |
Time |
09:53 |
Rev Time |
3.50 |
| Received By |
jwitmer |
Date |
2011-12-06 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2011-12-06 16:55:02 | BUILDING PLAN REVIEW | | | PERMIT:11120073 | | | ADD: 700 N CONGRESS | | | CONT: TO BE DETERMINED | | | CONTACT: JEFF HALVERSON | | | TEL: (561)644-7416 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | ARCHITECT: REG RICK GONZALEZ | | | TEL: 659-2383 | | | STRUCTURAL ENGINEER: ANDREW MORGAN P. E. | | | TEL: 881-8999 | | | | | | 1ST REVIEW PLANS DATED 11/09/11 | | | | | | ACTION: DENIED | | | | | | 1) 106.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS: | | | 1A)106.3.5.(1) ENERGY CALCULATIONS- MECHANICAL | | | | | | 1B) 106.3.5(8) STRUCTURAL REQUIREMENTS SHALL INCLUDE, | | | SOIL CONDITIONS/ANALYSIS | | | | | | 1C) 106.3.5(11). INTERIOR REQUIREMENTS SHALL INCLUDE | | | THE FOLLOWING: | | | INTERIOR FINISHES (FLAME SPREAD/SMOKE DEVELOPMENT) | | | LIGHT AND VENTILATION | | | SANITATION | | | | | | 1D) 12. SPECIAL SYSTEMS: LIFTS- DUMBWAITERS | | | | | | 1E) SHEET S-01 FOUNDATION NOTE# 1 REQUIRES A FOUNDATION | | | REPORT. | | | 1802.2.1 QUESTIONABLE SOIL. WHERE THE CLASSIFICATION, | | | STRENGTH OR COMPRESSIBILITY OF THE SOIL ARE IN DOUBT OR | | | WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED | | | IN THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL | | | REQUIRE THAT THE NECESSARY INVESTIGATION BE MADE. SUCH | | | INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF | | | SECTIONS 1802.4 THROUGH 1802.6. | | | | | | 2) S-02 WIND DESIGN CRITERIA: | | | 2A) THE STRUCTURAL PLANS S02 INDICATE A DESIGN TO 195 | | | MPH. THE ASCE 7-05 ONLY GO TO 170 MPH, 3 SECOND | | | GUST.THE ASCE 7-10 WILL NOT TAKE EFFECT UNTIL MARCH | | | 15/2012 WHEN THE NEW 2010 FBC GOES INTO EFFECT. PLEASE | | | ALSO NOTE THE BUILDING CATEGORY IS APPARENTLY A II | | | SINCE THE IMPORTANCE FACTOR IS ONLY FIGURED TO BE 1.0. | | | THIS BUILDING IS TO BE CONSIDERED THE EOC FOR THE CITY | | | . PLEASE REVIEW ASCE 7-05 TABLE 1-1, THE BUILDING | | | CATEGORY SHOULD BE A BUILDING CATEGORY IV WITH A | | | IMPORTANCE FACTOR OF 1.15. FIRE, RESCUE, DESIGNATED | | | EMERGENCY PREPAREDNESS COMMUNICATIONS OPERATIONS | | | CENTERS THAT ARE TO BE DESIGNED AS ESSENTIAL | | | FACILITIES. | | | | | | 2C) PLEASE ALSO PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | NEW STRUCTURE. | | | HEIGHT, BUILDING. THE VERTICAL DISTANCE FROM GRADE | | | PLANE TO THE AVERAGE HEIGHT OF THE HIGHEST ROOF | | | SURFACE. 502.1. THIS WILL DETERMINE WHICH MULTIPLIERS | | | TO BE USED IN CONSIDERING PRESSURES. | | | | | | 3) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING& FAC | | | RULE 9B-72, PLEASE PROVIDE 2 COPIES OF PRODUCT TESTING | | | REPORTS, MISSING REPORTS ARE AS FOLLOWS: | | | 3A) FIXED GLAZING, STOREFRONT | | | 3B) OPERABLE GLAZING UNITS | | | 3C) MULLIONS, HORIZONTAL AND VERTICAL | | | 3D) GLASS BLOCK | | | 3E) EXTERIOR GLAZED SWING DOORS | | | 3F) EXTERIOR INSULATED METAL SWING DOORS | | | 3G) BI-FOLD APPARATUS BAY DOORS/ WITH TRANSOM | | | 3H) EXTERIOR ROOF WALL ACCESS DOOR/ FRAME (H) | | | 3I) DOUBLE ACCESS PANEL ROOF HATCH, INSULATED -182.6. | | | 3J) WALL LOUVERS | | | 3K) A/C ROOF TOP A/C STANDS | | | 3L) ROOF ASSEMBLIES FLAT ROOF INCLUSIVE OF ROOF TOP | | | INSULATION. | | | 3M) ROOF ASSEMBLIES SLOPED ROOF, METAL ROOF SYSTEMS | | | -266.9 ZONE 3 AND -372.5 ROOF OVERHANGS WITHIN ZONE# 3. | | | 3N) BAHAMA SHUTTERS WITH PRODUCT APPROVAL FOR CLOSED | | | POSITION AND ENGINEERING ANALYSIS FOR SHUTTERS WHEN | | | LEFT IN THE OPEN POSITION IN THE CASE OF A HIGH WIND | | | EVENT. | | | 3O) ROOFTOP EXHAUST FANS | | | | | | 4) PLEASE THE CONTRACTOR DOES HAVE THE OPTION TO SUBMIT | | | THESE PRODUCT APPROVALS AT A LATER DATE (AFTER PERMIT | | | ISSUANCE), TO DO SO WILL BE CONSIDERED A REVISION ( FOR | | | EACH APPROVAL) AND REQUIRE ADDITIONAL FEES AND REVIEWS. | | | 106.3.5.1.1(8) STRUCTURAL REQUIREMENTS SHALL INCLUDE | | | BUILDING ENVELOPE. | | | | | | 5) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 6) PLEASE NOTE, 1609.1.4 PROTECTION OF OPENINGS IN | | | WIND-BORNE DEBRIS REGIONS, EXTERIOR GLAZING THAT | | | RECEIVES POSITIVE PRESSURE IN THE LOWER 60 FEET (18.3 | | | M) IN BUILDINGS SHALL BE ASSUMED TO BE OPENINGS AND THE | | | BALANCE OF GLAZED OPENINGS IN THE REST OF THE BUILDING | | | SHALL BE ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT | | | RECEIVES POSITIVE PRESSURE IS IMPACT RESISTANT OR | | | PROTECTED WITH AN IMPACT RESISTANT COVERING MEETING THE | | | REQUIREMENTS OF SSTD 12, ASTM E 1886 AND ASTM E 1996, | | | OR MIAMI-DADE TAS 201, 202 AND 203 REFERENCED THEREIN | | | AS FOLLOWS: 1. GLAZED OPENINGS LOCATED WITHIN 30 FEET | | | (9.1 M) OF GRADE SHALL MEET THE REQUIREMENTS OF THE | | | LARGE MISSILE TEST. | | | ASTM E 1996 REQUIREMENTS DO HAVE A MORE RESTRICTIVE | | | REQUIREMENT FOR LARGE MISSILE IMPACT TESTING | | | REQUIREMENT FOR ESSENTIAL FACILITIES OF IMPACT SPEED OF | | | 80 FPS WITH A 9.0 LB 2X4 MISSILE. | | | | | | 7)SHEET M-1.03, ALL ROOF TOP EQUIPMENT SHALL PROVIDE | | | DOCUMENTATION HOW THE EXTERIOR CABINET OR ENVELOPE OF | | | APPLIANCE MEETS THE WIND LOAD REQUIREMENTS OF 1609. | | | WIND RESISTANCE. MECHANICAL EQUIPMENT, APPLIANCES AND | | | SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED AND | | | INSTALLED TO RESIST WIND PRESSURES ON THE EQUIPMENT AND | | | THE SUPPORTS AS DETERMINED IN ACCORDANCE WITH THE | | | FLORIDA BUILDING CODE, BUILDING. 301.12 FBC MECHANICAL/ | | | 2007 | | | | | | 8) SHEET A-4.01 NOTES FOR THE ROOFING ASSEMBLIES, NOTE | | | 601 INDICATES ROOF SHEATHING REFER TO STRUCTURALS, | | | NEITHER SHEET S01 STEEL DECK NOR STEEL JOIST PROVIDE | | | THE TYPE OF ROOF SHEATHNG TO BE USED ON THE GALVANIZED | | | DECKING. S31 NOTES FOR ROOF DECKING ALSO FAIL TO | | | PROVIDE THE TYPE OF ROOF SHEATHING TO BE INSTALLED. | | | | | | 9) SHEET A-4.01 NOTE 908 INDICATES THE USE OF A | | | ALUMINUM ACCESS FLOOR SYSTEM, 24"X24" PANELS, 12 INCH | | | HIGH PEDESTALS. PLEASE PROVIDE MANUFACTURERS SPEC SHEET | | | FOR THIS PRODUCT AND ALLOWABLE LIVE LOADS TABLE 1607.1, | | | COMPUTER ROOMS SHALL BE DESIGNED FOR HEAVIER LOADS | | | BASED ON THE ANTICIPATED OCCUPANCY. TYPE OF MATERIALS | | | THIS PRODUCT IS MANUFACTURED 805.1. THE COMMAND CENTER | | | INDICATES THE USE OFTHIS PRODUCT PLEASE PROVIDE WALL | | | DETAIL BETWEEN THE COMMAND CENTER AND R-2 ADJACENT | | | OCCUPANCY. | | | | | | 10) SHEET A-4.11 DETAIL#1 & 3A INDICATES THE USE OF | | | STONE VENEER, PLEASE PROVIDE ATTACHMENT METHODS. | | | 1405.5 ANCHORED MASONRY VENEER. ANCHORED MASONRY VENEER | | | SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1405.5, | | | 1405.6, 1405.7 AND 1405.8 AND SECTIONS 6.1 AND 6.2 OF | | | ACI 530/ASCE 5/TMS 402. | | | | | | 11) SHEET A-4.11 STONE VENEER MISSING THE CONCRETE | | | BEARING EDGE. 2114.2 CONCRETE BEARING LEDGE. BRICK, | | | STONE OR OTHER VENEER SHALL BE SUPPORTED BY A | | | CONCRETE-BEARING LEDGE AT LEAST EQUAL TO THE TOTAL | | | THICKNESS OF THE BRICK, STONE OR OTHER VENEER, WHICH IS | | | POURED INTEGRALLY WITH THE CONCRETE FOUNDATION. NO | | | SUPPLEMENTAL CONCRETE FOUNDATION POURS WHICH WILL | | | CREATE A HIDDEN COLD JOINT SHALL BE USED WITHOUT | | | SUPPLEMENTAL TREATMENT IN THE FOUNDATION UNLESS THERE | | | IS AN APPROVED PHYSICAL BARRIER. AN APPROVED PHYSICAL | | | BARRIER SHALL ALSO BE INSTALLED FROM BELOW THE WALL | | | SILL PLATE OR FIRST BLOCK COURSE HORIZONTALLY TO EMBED | | | IN A MORTAR JOINT. IF MASONRY VENEER EXTENDS BELOW | | | GRADE, A TERMITE PROTECTIVE TREATMENT MUST BE APPLIED | | | TO THE CAVITY CREATED BETWEEN THE VENEER AND THE | | | FOUNDATION, IN LIEU OF A PHYSICAL BARRIER. | | | | | | EXCEPTION: VENEER SUPPORTED BY A SHELF, ANGLE OR LINTEL | | | SECURED TO THE FOUNDATION SIDEWALL IN ACCORDANCE WITH | | | ACI 530/ASCE 5/TMS 402, PROVIDED AT LEAST A 6-INCH (152 | | | MM) CLEAR INSPECTION SPACE OF THE FOUNDATION SIDEWALL | | | EXTERIOR EXIST BETWEEN THE VENEER AND THE TOP OF ANY | | | SOIL, SOD, MULCH OR OTHER ORGANIC LANDSCAPING | | | COMPONENT, DECK, APRON, PORCH, WALK OR ANY OTHER WORK | | | IMMEDIATELY ADJACENT TO OR ADJOINING THE STRUCTURE. | | | | | | 12) A-4.11 DETAIL# 2 NOTE 704 INDICATES THE | | | INSTALLATION OF RIGID INSULATION BOARD; PLEASE NOTE THE | | | REQUIREMENTS IN 2603.4 THERMAL BARRIERS. EXCEPT AS | | | PROVIDED FOR IN SECTIONS 2603.4.1 AND 2603.9, FOAM | | | PLASTIC SHALL BE SEPARATED FROM THE INTERIOR OF A | | | BUILDING BY AN APPROVED THERMAL BARRIER OF 0.5-INCH | | | (12.7 MM) GYPSUM WALLBOARD OR EQUIVALENT THERMAL | | | BARRIER MATERIAL THAT WILL LIMIT THE AVERAGE | | | TEMPERATURE RISE OF THE UNEXPOSED SURFACE TO NOT MORE | | | THAN 250??F (120??C) AFTER 15 MINUTES OF FIRE EXPOSURE, | | | COMPLYING WITH THE STANDARD TIME-TEMPERATURE CURVE OF | | | ASTM E 119. THE THERMAL BARRIER SHALL BE INSTALLED IN | | | SUCH A MANNER THAT IT WILL REMAIN IN PLACE FOR 15 | | | MINUTES BASED ON FM 4880, UL 1040, NFPA 286 OR UL 1715. | | | COMBUSTIBLE CONCEALED SPACES SHALL COMPLY WITH SECTION | | | 717. | | | | | | NOTE BOTH THE FIRST FLOOR AND SECOND FLOOR INDICATE THE | | | USE OF SUSPENDED ACOUSTICAL CEILING, PLEASE PROVIDE | | | RATING AND CLIP SYSTEM FOR RATING THE CEILING TILE. | | | | | | PLEASE ALSO BE AWARE OF MECHANICAL 602.2.1.5.1 PLENUM | | | RETURNS. FOAM PLASTIC INSULATION SHALL BE SEPARATED | | | FROM THE PLENUM BY A THERMAL BARRIER COMPLYING WITH | | | SECTION 2603.9 OF THE FBC-BUILDING. | | | | | | 13) LS1 THE PLANS INDICATE STORAGE ROOMS 1.18 & 2.03 | | | BOTH TO BE STORAGE ROOMS THE PLANS DO NOT PROVIDE ANY | | | WALL TYPE DESIGNATION FOR THE RESISTING OF SMOKE.SEE | | | SECTION 508.2.2.1 & TABLE 508.2. | | | | | | 14) LS1 THE PLANS ALSO INDICATES THE ELEVATOR ENTRY IN | | | THE LOBBY DIRECTLY ACROSS FROM THE STAIR TOWER 3.51 | | | WHICH EMPTIES INTO THE LOBBY WHICH IS A CONTINUATION OF | | | THE STAIRWAY. | | | FBC-B 1020.1.1 ELEVATORS SHALL NOT OPEN INTO AN EXIT | | | ENCLOSURE. WHERE INTERIOR EXIT ENCLOSURES ARE EXTENDED | | | TO THE EXTERIOR OF A BUILDING BY AN EXIT PASSAGEWAY, | | | THE DOOR ASSEMBLY FROM THE EXIT ENCLOSURE TO THE EXIT | | | PASSAGEWAY SHALL BE PROTECTED BY A FIRE DOOR ASSEMBLY | | | CONFORMING TO THE REQUIREMENTS IN SECTION 715.4. FIRE | | | DOOR ASSEMBLIES IN EXIT ENCLOSURES SHALL COMPLY WITH | | | SECTION 715.4.4. IF THIS EXIT IS PART OF AN EXIT | | | PASSAGE WAY NO FURNITURE CAN BE IN THIS AREA. FBC | | | 1021.1. | | | | | | 15) LS 2 ROOM # 3.11, 3.14.3.15 & 3.61ARE SLEEPING | | | ROOMS BUT NO OCCUPANCY SEPERATION WALLS THE TOTAL | | | SQUARE FT FOR THESE ROOMS IS 1172 WHICH IS OVER THE 10% | | | OF 10,213 SQ FT | | | LISTED ON LS-2. PLEASE SEE FBC-B TABLE 508.3.3. | | | | | | 16) LS-2 THE MECHANICAL ROOM # 3.24 IS MISSING A PAIR | | | OF EXTERIOR DOUBLE DOORS, DO THEY LEED ONTO THE ROOF | | | DECK? FBC-B 1609. | | | | | | 17) SHEET A-1.01, A-1.02 & A1.03 BOTH INDICATE S1 & S2 | | | WALL TAG TYPES, PLANS FAIL TO INCLUDE A DETAIL SHEET | | | INDICATING TYPES OF WALL CONSTRUCTION. PLEASE PROVIDE | | | WALL TYPE TAGS FOR IDENTIFICATION FOR FIRE RATED WALLS, | | | SMOKE RATED WALLS AND INTERIOR NON RATED WALLS. | | | PLEASE USE UL, GYPSUM OR OTHER NATIONALLY APPROVED | | | SYSTEM. 106.3.5.1.1(4), TABLE508.3.3.4 AND 708.1. | | | | | | 18) SHEET A6.01 WILL NEED TO BE UPDATED ONCE THE WALL | | | SCHEDULE IS UPDATED TO SHOW ALL RATED WALLS AND | | | PENETRATIONS FBC-B TABLE 715.4. | | | | | | 19) LS-2 NOR A-1.2 INDICATE THE USAGE OF THE MEZZANINE | | | THE FORMER PERMIT 10030034 SHEET A-1.02 INDICATED THIS | | | TO BE A TRAINING AREA. | | | L.S. 2 MEZZANINE AREA, PLANS INDICATE THIS TO BE A | | | TRAINING AREA 869/15= 58 OCCUPANTS, | | | TABLE 1015.1 REQUIRES 2 EXITS. | | | 20) L. S. 2 MEZZANINE LEVEL DOES NOT SHOW VERTICAL | | | ACCESSIBILITY REQUIREMENTS 11-4.1.3(5). | | | 11-1.3 THIS CODE ESTABLISHES STANDARDS FOR | | | ACCESSIBILITY TO PLACES OF PUBLIC ACCOMMODATION AND | | | COMMERCIAL FACILITIES BY INDIVIDUALS WITH DISABILITIES. | | | THIS CODE SHALL ALSO APPLY: TO STATE AND LOCAL | | | GOVERNMENT FACILITIES PURSUANT TO SECTION 553.503, | | | FLORIDA STATUTES; | | | CHAPTER 11 | | | REQUEST FOR WAIVER FROM ACCESSIBILITY REQUIREMENTS | | | CHAPTER 553, | | | PART V, FLORIDA STATUTES AUGUST 1999 | | | PART C THIS APPLICATION IS AVAILABLE IN ELECTRONIC | | | FORMAT AT: | | | HTTP://WWW.DCA.STATE.FL.US/FHCD/FBC/ACCESS_WAIVER/WAIVE | | | RAP.HTM. | | | | | | 21) A-6.01/ A-7.01 & A-4.11 THE MAIN LOBBY IS TO BE | | | CONSIDERED A 2 STORY ATRIUM, THE GLAZING WITHIN THIS | | | AREA STORE FRONT FIRST FLOOR AND SECOND FLOOR WILL NEED | | | TO MEET THE REQUIREMENTS FOR A 1 HOUR RATED WALL. | | | A-7.01 WINDOW SCHEDULE DOES NOT INDICATE ANY FIRE RATED | | | WINDOWS. PLEASE ALSO REVIEW EXCEPTION UNDER 404.5 FOR | | | WATER CURTAIN. NOTE THERE CAN BE NO INTERMEDIATE | | | HORIZONTAL MULLIONS WITH USE OF WATER CURTAIN. SHEET | | | A-1.02 DOES HAVE A CUT SECTION THROUGH THE LOBBY DETAIL | | | 2/A4.11 WHICH IS FOR THE EXTERIOR WALL? | | | | | | 22) PLEASE PROVIDE COMPLIANCE WITH: FL S 255.2575 | | | ENERGY-EFFICIENT & SUSTAINABLE BUILDINGS. PLANS THAT | | | ARE COMMENCED AFTER JULY1, 2008 SHALL BE CONSTRUCTED TO | | | MEET THE UNITED STATES GREEN BUILDING COUNCIL (USGBC), | | | LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN (LEED) | | | RATING SYSTEM, THE GREEN BUILDING INITIATIVE'S GREEN | | | GLOBAL RATING SYSTEM, THE FLORIDA GREEN BUILDING | | | COALITION STANDARDS, OR A NATIONALLY RECOGNIZED, HIGH | | | PERFORMANCE GREEN BUILDING RATING SYSTEM AS APPROVED BY | | | THE DEPARTMENT OF MANAGEMENT SERVICES. | | | | | | 23) WEST PALM BEACH ADMINISTRATIVE CODE 109.3.7 | | | BUILDINGS REQUIRING SPECIAL ONSITE INSPECTORS: | | | 1) TYPE I OR TYPE II CONSTRUCTION | | | 5) BUILDINGS WITH AREAS GREATER THAN 20,000 SQ FT | | | | | | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | JIM WITMER C. B. O. | | | COMMERCIAL COMBINATION PLAN REVIEW | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | | CUSTOMER SERVICE SURVEY AT: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2013-07-01 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-07-01 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-07-01 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2013-06-24 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-06-24 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-21 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2013-06-24 13:33:43 | 11120073 | | | 700 N. CONGRESS | | | NEW FIRE STATION | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | SHEET E-0.01 | | | INDICATE THE CLASSIFICATIONS OF THE FACILITY UNDER THE | | | 2008 NATIONAL ELECTRIC CODE REQUIREMENTS FOR CRITICAL | | | OPERATIONS POWER SYSTEMS (COPS). NEC ARTICLE 708 | | | | | | SHEET E-0.03 | | | ELECTRICAL CIRCUITS AND LIGHTING POLES HAVE NOT BEEN | | | SPECIFIED FOR THE SITE LIGHTING. PROVIDE SIGNED AND | | | SEALED WIND LOADING CERTIFICATION FOR THE LIGHT POLE | | | ASSEMBLY WITH FIXTURES. THIS MAY BE ACCOMPLISHED UNDER | | | A SEPERATE PERMIT. 2010 FBC 1609.1., ASCE 7-10 | | | | | | SHEET E-0.04 | | | VERIFY THE GENERATOR SERVICE DISCONNECT IS SERVICE | | | RATED AND IS GROUNDED FAULT PROTECTED (GFP) OR HAS A | | | GFP INDICATOR. SEE NEC 701.17 | | | | | | THE SECONDARY OC PROTECTION ON T-L1 APPEARS TO EXCEED | | | THE MAXIMUM ALLOWABLE RATING. NEC 450.3(B) | | | | | | SHEET E-1.01 | | | ELECTRICAL CIRCUITS SERVING THE LIVING AND SLEEPING | | | AREAS REQUIRE AFCI PROTECTION. NEC 210.12, 210.18 | | | | | | IDENTIFY THE MINIMUM WIRING METHOD PROPOSED IN ALL | | | CLASS 1 DIVISION 2 AREAS. NEC 501.10(B), 501.15(B) | | | | | | SHEET E-4.01 | | | THE ELECTRICAL PLAN IS UNCLEAR AS TO THE CLASSIFICATION | | | OF THE IT ROOMS UNDER THE ELECTRIC CODE. NEC 645.4 | | | | | | THE PLANS ARE UNCLEAR AS TO HOW THE IT ROOMS ARE TO BE | | | VENTILATED. NEC 645.4, 480.9 | | | | | | PROVIDE A LABELING SCHEDULE FOR THE SAFETY SIGNAGE | | | REQUIRED FOR THE ELECTRICAL EQUIPMENT AND ELECTRICAL | | | ROOMS. NEC 110.22, 110.16, 701.9 | | | | | | NOTE: SEPARATE PERMITS ARE REQUIRED FOR THE LIGHTNING | | | PROTECTION SYSTEM, SITE LIGHTING, AUDIO, SECURITY, SITE | | | TRAILERS, GATES, DATA AND PHONES. | | | | | | | | | ROBERT LECKY | | | ELECTRIC PLANS EXAMINER | | | 561-805-6718 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2013-06-05 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-06-05 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-05 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2013-06-05 08:47:12 | 6-5-13 - 3RD REVIEW | | | | | | ALL ITEMS ON THE INITIAL REVIEW WERE NOT INCLUDED WITH | | | THE RECENT SUBMITTAL. ALSO, ANY REVISIONS MUST BE | | | INSERTED IN THE ROLLED SET OF DRAWINGS. | | | PLEASE MAKE THE NECESSARY CHANGES- | | | VB |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2012-05-07 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-05-07 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-05-07 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2012-05-07 11:01:41 | NO RESPONSE TO INITIAL REVIEW WAS INCLUDED WITH THIS | | | SUBMITTAL. RL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-01-03 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-01-03 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-12-28 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2012-01-03 11:28:53 | THURSDAY, DECEMBER 29, 2011 | | | | | | 1120073 | | | 700 N. CONGRESS | | | NEW FIRE STATION | | | | | | VERIFY THE GENERATOR SERVICE DISCONNECT IS SERVICE | | | RATED AND IS GROUNDED FAULT PROTECTED (GFP) OR HAS A | | | GFP INDICATOR. SEE NEC 701.17 | | | THE ELECTRICAL PLAN IS UNCLEAR AS TO THE CLASSIFICATION | | | OF THE IT ROOMS UNDER THE ELECTRIC CODE. NEC 645.4 | | | THE ELECTRICAL PLAN IS UNCLEAR AS TO THE CLASSIFICATION | | | OF THE PREMISES WIRING UNDER THE ELECTRIC CODE FOR | | | CRITICAL OPERATIONS POWER SYSTEMS (COPS). NEC 708 | | | THE PLANS ARE UNCLEAR AS TO HOW THE IT ROOMS ARE TO BE | | | VENTILATED. NEC 645.4, 480.9 | | | PROVIDE A LABELING SCHEDULE FOR THE SAFETY SIGNAGE | | | REQUIRED FOR THE ELECTRICAL EQUIPMENT AND ELECTRICAL | | | ROOMS. NEC 110.22, 110.16, 701.9 | | | IDENTIFY THE MINIMUM WIRING METHOD PROPOSED IN ALL | | | CLASS 1 DIVISION 2 AREAS. NEC 501.10(B), 501.15(B) | | | ELECTRICAL CIRCUITS AND LIGHTING POLES HAVE NOT BEEN | | | SPECIFIED FOR THE SITE LIGHTING. | | | ELECTRICAL CIRCUITS SERVING LIVING AND SLEEPING AREAS | | | REQUIRE AFCI PROTECTION. NEC 210.12, 210.8 | | | | | | NOTE: SEPARATE PERMITS ARE REQUIRED FOR THE LIGHTNING | | | PROTECTION SYSTEM, SITE LIGHTING, AUDIO, SECURITY, DATA | | | AND PHONES. | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
5 |
Status |
P |
Date |
2013-07-10 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2013-07-10 |
Time |
|
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2013-07-10 |
Time |
|
Sent To |
B |
|
| Notes |
| 2013-07-10 07:53:35 | PASSED |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2013-05-09 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2013-05-09 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2013-05-09 |
Time |
|
Sent To |
I |
|
| Notes |
| 2013-05-09 08:12:53 | PROVISO: | | | | | | ROW PERMIT WILL BE REQUIRED TO TAP WATERMAIN ON HANK | | | AARON DRIVE.. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2012-07-14 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2012-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
mgonzale |
Date |
2012-07-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2012-07-14 13:01:53 | A SEPARATE SUBMITTAL MUST BE MADE TO: | | | ENGINEERING SERVICES DEPARTMENT | | | FOR ROW CONSTRUCTION | | | 401 CLEMATIS ST. | | | WEST PALM BEACH, FL 33402 | | | (561) 494-1098 | | | | | | COMMENTS APPLICABLE TO ON-SITE: | | | #1 CISTERN TANK FILL MUST HAVE AN AIR GAP. PROVIDE | | | DETAIL. | | | #2 PROVIDE MEP DRAWINGS REFERENCED IN CIVIL AND | | | MECHANICAL PLANS, THESE PLANS SHOULD PROVIDE DETAIL OF | | | FUEL TANKS, DRAINAGE TANK, SANITARY TANKS, AND CORRECT | | | PIPING LOCATIONS AND CLEARANCES. | | | #3 MECHANICAL PLAN STILL SHOWS NOTES PLACED WHERE OLD | | | BUILDING ORIENTATION OF ELEMENTS WHERE. | | | #4 HANDICAP PARKING DETAIL IS MISSING SOME DIMENSIONS. | | | #6 CHANGE COVER SHEET: DIRECTOR OF ENGINEERING IS | | | DANIELLE E. SLATERPRYCE, P.E. | | | DIRECTOR ENGINEERING SERVICES & PUBLIC WORKS (REMOVE | | | MR. JONATHAN BRAMLEY) | | | #7 CONCRETE EXPANSION JOINTS NEED TO BE NOTED ON PLANS | | | FOR CONCRETE PARKING AREAS. | | | #8 SITE WILL CONSIST OF ALL CONCRETE DRIVE AND PARKING | | | AREAS. ON SHEET C6 ALL DETAILS IDENTIFY ASPHALT, REMOVE | | | ALL DETAILS NOT REQUIRED. | | | #9. TAPS FOR FIRE, DOMESTIC AND CISTERN BACK-UP | | | (IRRGATION) MUST BE INDIVIDUALLY TAPPED OFF WATERMAIN | | | ON HANK AARON DRIVE. HYDRANT ALSO. CONFIRM WITH FIRE | | | DEPARTMENT TO SEE IF THEY DON'T NEED A PRIVATE HYDRANT | | | ON-SITE. SOMETIMES THEY REQUIRE ONE FOR TRAINING | | | PURPOSES. | | | #10 GREASE SEPARATOR DOES NOT SHOW CONNECITON TO THE | | | SEWER. SHOW ON CIVIL SHEET C10. | | | #11 PROVIDE STRUCTURAL WALL DETAIL FOR WALL ALONG THE | | | EAST PERIMETER OF THE PROPERTY. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2012-01-23 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2012-01-23 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2012-01-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2012-01-23 18:34:08 | A SEPARATE SUBMITTAL MUST BE MADE TO: | | | | | | ENGINEERING SERVICES DEPARTMENT | | | ATTENTION: BRIAN MOREE, CONSTRUCTION SUPERVISOR | | | 401 CLEMATIS ST. | | | WEST PALM BEACH, FL 33402 | | | (561) 494-1098 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2013-07-09 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-07-09 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-07-09 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2013-06-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2013-06-18 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2013-06-18 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2013-06-18 07:40:01 | FIRE STATION # 5 AND CITY OF WEST PALM BEACH EMERGENCY | | | OPERATIONS CENTER | | | 700 NORTH CONGRESS AVENUE | | | PERMIT # 11120073 | | | | | | CORRESPONDENCE FROM REG ARCHITECTS, INC., DATED MAY 31, | | | 2013 APPEARS TO SATSFY COMMENTS FROM THIS DEPARTMENT. | | | ADDITONAL REVIEWS WILL BE REQUIRED FOR THE PROJECT FOR | | | THE NUMEROUS SHOP DRAWINGS EXPECTED FOR THIS PROJECT. | | | | | | | | | MICHAEL E. CARSILLO, ASSISTANT FIRE CHIEF | | | WEST PALM BEACH FIRE RESCUE |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2013-05-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2013-05-14 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2013-05-14 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2013-05-14 13:32:01 | FIRE STATION # 5 AND THE EMERGENCY OPERATIONS CENTER | | | 700 NORTH CONGRESS AVENUE | | | PERMIT NUMBER 11120073 | | | | | | 1. SEPARATE PLANS AND PERMITS REQUIRED FO THE DEISEL | | | FUEL TANK, LP GAS TANK, FIRE SPRINKLER AND FIRE ALARM | | | SYSTEMS. | | | | | | 2. LANDSCAPE IS TO BE PLACED SEVERAL FEET AWAY FROM THE | | | BUILDING TO PREVENT PESTS, AND RODENTS FROM ENTERING | | | THE BUILDING. | | | | | | 3. SEVERAL TREES LOCATED ON THE SITE WANT TO BE SAVED. | | | THEY WERE PLANTED BY PERSONNEL AS SAPLINGS AND WANT TO | | | BE SAVED. | | | | | | 4. SEPARATE PLANS AND PERMITS REQUIRED FOR SLIDING GATE | | | DISPLAYED ON PAGE A-0.03. | | | | | | 5. SEPARATE PLANS AND PERMITS REQUIRED FOR ALL LOW | | | VOLTAGE WIRING AND APPURTENANT EQUIPMENT. | | | | | | 6. THERE APPEARS TO BE NO CEILING MOUNTED SPEAKERS IN | | | ROOM 1.28 AND 1.29 AS SHOWN ON PAGE A-2.01. | | | | | | 7. TWO CEILING MOUNTED SPEAKERS SHOWN DIRECTLY NEXT TO | | | ONE ANOTHER IN ROOM 3.20 ON PAGE A-2.01. | | | | | | 8. NO CEILING MOUNTED SPEAKERS DISPLAYED ON SHEET | | | A-2.02 FOR AREA 1.17. | | | | | | 9. ADDRESS NEEDS TO BE DISPLAYED ON ONLY ONE ELEVATION. | | | ON SHEET A-3.01 IT IS DISPLAYED ON WEST AND SOUTH | | | ELEVATIONS. | | | | | | 10. THE GENERATOR INSTALLATION IS TO COMPLY WITH NFPA | | | 110, 37, AND 30. | | | | | | 11. COULD NOT LOCATE A 5.7 ON FLOOR FINISH SCHEDULE ON | | | PAGE A-5.02. | | | | | | 12. ALL FIRE DAMPERS ARE TO BE DROP TESTED AFTER | | | INSTALLATION TO ENSURE PROPER OPERATION. | | | | | | 13. THE FIRE ALARM CONTROL PANEL IS STILL SHOWN IN THE | | | ROOF ELECTRICAL ROOM ON SHEET E-3.03 WHICH IS NOT | | | ACCEPTABLE TO THIS OFFICE. PLEASE RELOCATE THIS PANEL | | | TO THE FIRST FLOOR ELECTRICAL ROOM. | | | | | | 14. SEPARATE PLANS AND PERMITS REQUIRED FOR THE | | | PRE-ACTION SPRINKLER SYSTEM SHOWN ON PAGE FP-7.01. | | | | | | 15. ELECTRONIC SWITCHES ARE REQUIRED ON FIRE-LINE | | | BACKFLOW DEVICES. SEE NOTE # 3 ON SHEET C12. | | | | | | DENIED | | | | | | | | | MICHAEL E. CARSILLO, ASSISTANT FIRE CHIEF | | | WEST PALM BEACH FIRE RESCUE |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2012-05-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2012-05-23 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2012-05-23 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2012-05-23 15:22:58 | FIRE STATION # 5 AND THE EMERGENCY OPERATIONS CENTER | | | (EOC) | | | 700 NORTH CONGRESS AVENUE | | | NEW CONSTRUCTION | | | PERMIT # 11120073 | | | | | | 1. ON COVER SHEET IT LISTS JONATHAN BRAMLEY AS | | | ENGINEERING DIRECTOR. MR. BRAMLEY HAS LEFT THE CITY. | | | | | | 2. SEPARATE PLANS AND PERMITS REQUIRED FOR DIESEL FUEL | | | AND LP GAS TANKS. | | | | | | 3. SEPARATE PLANS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER SYSTEM. THE FIRE DEPARTMENT CONNECTION (FDC) | | | IS TO BE LOCATED WITHIN 150 FEET OF A FIRE HYDRANT. | | | | | | 4. FIRE LINE BACKFLOW DEVICE IS TO BE EQUIPPED WITH | | | TAMPER SWITCHES, CHAIN AND LOCK. | | | | | | 5. THE LARGE PAINTING OF THE STATION MASCOT (RHINO) IS | | | TO BE SAVED FOR FUTURE USE DURING THE DEMOLITION PHASE | | | OF THE PROJECT. THE PAINTING WILL BE INSTALLED IN THE | | | NEW FIRE STATION. | | | | | | 6. THE SLIDING GATE WHEN INOPERATIVE, MUST BE ABLE TO | | | BE OPENED MANUALLY. | | | | | | 7. EXIT SIGN IS MISSING ON SHEET LS-1 AT THE BOTTOM OF | | | THE STAIR 3.51. | | | | | | 8. THE NOTE IN THE CODE ANALYSIS BOX IS INCORRECT. THE | | | BUILDING IS EQUIPPPED WITH AN APPROVED FIRE SPRINKLER | | | SYSTEM (NFPA 13) NOT (NFPA 75). | | | | | | 9. ON SHEET A-2.01 THERE APPEARS TO BE NUMEROUS CEILING | | | MOUNTED SPEAKERS IDENTIFIED AS CS. IN MANYT CASES, THEY | | | APPEAR TO BE DIRECTLY NEXT TO ONE ANOTHER. | | | | | | 10. THE NUMBER OF AVAILABLE SLEEPING ACCOMODATIONS WAS | | | DISCUSSED WITH ALLAN ORTMAN ON MAY 22, 2012. HE | | | EXPLAINED THAT DURING AN ACTUAL EVENT STAFFING WILL BE | | | HELD AT A MINIMUM. | | | | | | 11. SMOKE DETECTORS WHEN INSTALLED SHALL BE A MINIMUM | | | OF AT LEAST THREE FEET FROM AIR CONDITIONER DIFFUSERS. | | | | | | 12. ON SHEET A-3.01 THE ADDRESS IS ILLUSTRATED ON TWO | | | ELEVATIONS. IT IS ONLY NEEDED ON ONE ELVATION. | | | | | | 13. FLOORING CORNERS SHOULD BE ROUNDED WHERE IT MEETS | | | WALLS SO CORNERS CAN BE CLEANED. | | | | | | 14. PROVIDE SEPARATE PLANS AND PERMITS FOR ANY CLEAN | | | AGENT SYSTEMS PLANNED TO BE INSTALLED. | | | | | | 15. MORE DETAILS NEEDED FOR SECURITY DEVICES PLANNED | | | FOR DOORS. | | | | | | 16. THERE APPEARS TO BE NO EMERGENCY LIGHTING IN | | | SEVERAL OFFICES ON THE FIRST AND SECOND FLOOR, WHEN | | | NORMAL POWER IS LOST. WILL WORK BE ABLE TO BE PERFORMED | | | IN THESE AREAS WHEN NORMAL POWER IS LOST. | | | | | | 17. EMERGENCY LIGHTS INSTALLED (GOGGLE EYES) ARE TO BE | | | INSTALED AT AN ELEVATION THAT CAN BE TESTED. | | | | | | 18. NO FIRE ALARM DEVICES SHOWN IN VEHICLE BAY ON SHEET | | | E-3.01. | | | | | | 19. ON PAGE E-3.03 THE FIRE ALARM CONTROL PANEL IS | | | DISPLAYED. A MORE SUITABLE LOCATION IS TO BE PROVIDED | | | ON THE FIRST FLOOR AND NOT LOCATED ON THE ROOF LEVEL. | | | THE FIRE ALARM SYSTEM IS TO BE MONITORED BY A CENTRAL | | | STATION APPROVED FOR CENTRAL STATION SERVICE. | | | | | | 20. PLEASE EXPLAIN PURPOSE OF THE CARD READERS SHOWN ON | | | SHEET T-0.02. | | | | | | 21. ALL FIRE DAMPERS AFTER INSTALLATION ARE TO BE DROP | | | TESTED TO ENSURE PROPER OPERATION. | | | | | | 22. SOFFITS OR ARCHITECTURAL DETAILS SHALL NOT | | | INTERFERE WITH ANY OPERATION OF ANY FIRE SPRINKLER | | | HEADS. | | | | | | | | | DENIED | | | | | | | | | MICHAEL E. CARSILLO, ASSISTANT FIRE CHIEF | | | WEST PALM BEACH FIRE RESCUE | | | 804-4707 PHONE | | | 804-4766 FAX |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-12-08 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-12-08 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-12-08 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2011-12-08 14:50:43 | FIRE STATION # 5 AND THE EMERGENCY OPERATIONS CENTER | | | 700 NORTH CONGRESS AVENUE | | | PLAN REVIEW COMMENTS FROM FIRE RESCUE | | | PLAN REVIEW FOR BID PLANS | | | RECEIVED: DECEMBER 2, 2011 | | | COMPLETED: DECEMBER 6, 2011 | | | | | | | | | 1. COVER SHEET I LISTS JONATHAN BRAMLEY AS ENGINEERING | | | SERVICES DIRECTOR. MR. BRAMLEY HAS LEFT EMPLOYMENT WITH | | | THE CITY. | | | | | | 2. SEPARATE PLANS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER AND FIRE ALARM SYSTEMS. | | | | | | 3. SEPARATE PLANS AND PERMITS REQUIRED FOR FLAMMABLE | | | LIQUID AND FLAMMABLE GAS STORAGE. | | | | | | 4. DEMOLITION ACTIVITIES ARE TO COMPLY WITH NFPA 241. | | | ALL DEBRIS SHALL BE LEGALLY DISPOSED OF IN ACCORDANCE | | | WITH STATE AND LOCAL REQUIREMENTS. | | | | | | 5. CLOSE COORDINATION IS TO OCCUR DURING CONSTRUCTION | | | PHASES 1, 2, AND 3. | | | | | | 6. SEPARATE PLANS AND PERMITS REQUIRED FOR HOOD, DUCT, | | | AND FIRE SUPPRESSION SYSTEMS. | | | | | | 7. SEPARATE PLANS AND PERMITS REQUIRED FOR PRE-ACTION | | | FIRE SPRINKLER SYSTEM. | | | | | | 8. ALL NEW FIRE MAINS AND THEIR APPURTENANCES ARE TO | | | COMPLY WITH NFPA 24, FIRE SERVICE MAINS AND THEIR | | | APPURTENANCES. | | | | | | 9. THE FIRE DEPARTMENT CONNECTION (FDC) SHALL BE | | | EQUIPPED WITH KNOX-LOCKING CAPS. | | | | | | 10. TACTILE SIGNAGE REQUIRED AT ALL REQUIRED EXIT | | | DOORS. | | | | | | 11. SEPARATE PLANS AND PERMITS REQUIRED FOR LOW VOLTAGE | | | SECURITY DEVICES AND CAMERAS. | | | | | | 12. SECURITY DEVICES WHEN INSTALLED SHALL NOT INTERFERE | | | WITH ANY EXITING FROM THE BUILDING. | | | | | | 13. ALL FIRE DAMPERS UPON INSTALLATION ARE TO BE DROP | | | TESTED TO ENSURE PROPER FUNCTION. | | | | | | 14. PLEASE PROVIDE PRODUCT APPROVAL INFORMATION FOR THE | | | DUCT WRAP PLANNED TO BE USED FOR THE KITCHEN EXHAUST | | | DUCT. | | | | | | 15. WHAT PREVENTS ODORS FROM ENTERING THE DORMITORY | | | AREA ON THE SECOND FLOOR FROM THE KITCHEN HOOD EXHAUST? | | | | | | 16. THE KITCHEN EXHAUST DUCT SHALL BE A MINIMUM OF AT | | | LEAST 10 FEET FROM AIR CONDITIONING EQUIPMENT. | | | | | | 17. ALL FIRE RATED WALLS ARE TO BE PROPERLY IDENTIFIED | | | WITH STENCILS OR PAINT. | | | | | | 18. SECURITY DOOR DEVICES SHOWN ON PAGE T-4.05 ARE | | | CONFUSING. DIFFERENT SECURITY DEVICES EXIST. THEY | | | INCLUDE MOTION SENSOR, PUSH TO EXIT, AND CARD READER. | | | | | | 19. A WIRE FOR THE LOCUTION APPEARS TO PASS THROUGH | | | STAIR 3.52. THIS IS NOT PERMITTED. | | | | | | 20. SPRINKLER HEADS SHALL NOT BE OBSTRUCTED BY | | | ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING SYSTEMS | | | OR ANY FIXTURES. | | | | | | 21. SHOULD ASBESTOS CONTAINING MATERIAL BE DISCOVERED, | | | AN ASBESTOS REMEDIATION PLAN SHALL BE FORWARDED TO THE | | | DIRECTOR OF CONSTRUCTION SERVICES AND THE ASSISTANT | | | FIRE CHIEF OF SUPPORT SERVICES. | | | | | | 22. ALL MECHANICAL AND ELECTRICAL ROOMS ARE TO BE | | | PROPERLY LABELED. | | | | | | 23. THE BUILDING ADDRESS ONLY NEEDS TO BE PLACED ON ONE | | | ELEVATION. THE ADDRESS IS TO BE PLACED ON THE ADDRESS | | | SIDE OF THE BUILDING. | | | | | | 24. ON PAGE E-7.01, A DEDICATED TELEPHONE CONNECTION | | | FOR THIRD PARTY NOTIFICATION IS DISPLAYED. A MINIMUM OF | | | AT LEAST TWO TELEPHONE LINES ARE REQUIRED. ALSO THE | | | MONITORING COMPANY IS TO BE APPROVED FOR CENTRAL | | | STATION MONITORING. | | | | | | 25. ALL ELECTRICAL WORK IS TO COMPLY WITH NFPA 70, THE | | | NATIONAL ELECTRICAL CODE. | | | | | | 26. ALL LIGHTNING PROTECTION SYSTEMS AND EQUIPMENT TO | | | COMPLY WITH NFPA 780. | | | | | | 27. ON SHEET E-3.03 THE FIRE ALARM PANEL APPEARS TO BE | | | LOCATED IN THE ROOF ELECTRICAL ROOM. THIS PANEL SHOULD | | | BE LOCATED ON THE FIRST FLOOR. | | | | | | 28. MORE DETAILS REQUIRED ON THE FUTURE 911 BY OTHERS | | | PLAZA. | | | | | | 29. ON SHEET C21 ELECTRONIC SWITCHES WILL BE REQUIRED | | | FOR THE FIRE LINE BACKFLOW DEVICE. | | | | | | 30. ALL SYSTEMS CONTAINED WITHIN THE BUILDING SHALL BE | | | INSTALLED IN APPROVED WORKMANLIKE MANNER AND MEET ALL | | | APPLICABLE CODES AND REGULATIONS. | | | | | | 31. ALL SMOKE DETECTION EQUIPMENT SHALL BE INSTALLED A | | | MINIMUM OF AT LEAST THREE FEET FROM ANY AIR | | | CONDITIONING DIFFUSERS. | | | | | | 32. PLEASE INDICATE ON THE PLANS WHAT SET POINTS (PARTS | | | PER MILLION) THAT THE CARBON MONOXIDE DETECTORS (CO) | | | WILL BE ACTIVATED AT. | | | | | | 33. COULD NOT LOCATE ON THE PLANS THE EMERGENCY | | | COMMUNICATION SYSTEM THAT IS TO BE INSTALLED OUTSIDE TO | | | CONTACT EMERGENCY SERVICES. | | | | | | 34. ALL STAIRS AND RAMPS SHALL BE PROVIDED WITH | | | HANDRAILS. | | | | | | 35. APPROPRIATE ACCESS PANELS ARE TO BE INSTALLED TO | | | ACCESS MECHANICAL EQUIPMENT. | | | | | | 36. DUCT SMOKE DETECTORS WHEN ACTIVATED SHALL CAUSE THE | | | FIRE ALARM SYSTEM TO ACTIVATE. | | | | | | 37. ALL UNDERGROUND FIRE MAINS AND FIRE SPRINKLER | | | PIPING IS REQUIRED TO BE HYDROSTATICALLY TESTED FOR TWO | | | HOURS AT 200 PSIG. | | | | | | 38. DUE TO THE NUMBER OF ITEMS THAT ARE NECESSARY TO | | | CONSTRUCT THIS FACILITY A TIME LINE IS TO BE DEVELOPED | | | TO ENSURE THE PROPER COORDINATION BETWEEN PALM BEACH | | | COUNTY COMMUNICATIONS, PALM BEACH COUNTY TRAFFIC, AND | | | THE CITY OF WEST PALM BEACH. | | | | | | 39. EXITS ARE REQUIRED TO BE KEPT UP WITH CONSTRUCTION. | | | | | | 40. TRASH AND DEBRIS SHALL BE REMOVED FROM THE SITE | | | DAILY. | | | | | | 41. WHEN REQUIRED FIRE AND LIFE SAFETY SYSTEMS ARE | | | TAKEN OUT OF SERVICE FOR MORE THAN FOUR HOURS IN A | | | TWENTY FOUR HOUR PERIOD A FIRE WATCH IS REQUIRED. | | | CONTACT IS ALSO TO BE MADE WITH THE BUREAU OF FIRE | | | PREVENTION. (804-4724) | | | | | | 42. IF CUTTING AND WELDING ACTIVITIES BECOME NECESSARY | | | ON THE SITE, COMPLIANCE WITH NFPA 51B IS REQUIRED. | | | | | | 43. NO INSTALLATIONS ARE TO OCCUR AT THE PREMISE | | | WITHOUT APPROVED PLANS AND A PERMIT. | | | | | | 44. APPROPRIATE SAFEGUARDS ARE TO BE PROVIDED WHEN | | | PERFORMING UNDERGROUND UTILITIES WORK ON THE SITE. | | | | | | 45. THE MECHANICAL DEPARTMENT WILL REQUIRE A COMPLETE | | | TEST AND BALANCE ON THE AIR CONDITIONING AND HOOD | | | MECHANICAL SYSTEMS. | | | | | | 46. PORTABLE FIRE EXTINGUISHERS WITH APPROVED SERVICE | | | TAGS ARE TO BE PROVIDED THROUGHOUT THE PREMISE. | | | | | | 47. THE SITE IS TO BE PROPERLY SECURED WHILE UNDER | | | CONSTRUCTION AND DEMOLITION. ONLY AUTHORIZED PERSONNEL | | | ARE PERMITTED ON THE SITE. NO TRESPASSING SIGNS WILL BE | | | NECESSARY ON THE SITE. | | | | | | 48. ALL EXCAVATION AT THE SITE IS TO BE ONLY PERFORMED | | | AFTER ALL UTILITIES HAVE BEEN PROPERLY LOCATED AND | | | MARKED. | | | | | | 49. THE EXISTING FIRE STATION IS TO REMAIN OPERATIONAL | | | TO CITIZENS, VISITORS, AND STAFF WHILE CONSTRUCTION | | | WORK IS BEING PERFORMED. | | | | | | 50. PRIOR TO ANY TEMPORARY CERTIFICATE OF OCCUPANCY IS | | | REQUESTED ALL REQUIRED FIRE AND LIFE SAFETY SYSTEMS ARE | | | TO BE INSPECTED, TESTED, AND APPROVED BY THE | | | APPROPRIATE INSPECTION DIVISION. | | | | | | MIKE CARSILLO, ASSISTANT FIRE CHIEF | | | WEST PALM BEACH FIRE RESCUE | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2013-06-25 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-06-25 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-06-25 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2013-07-05 08:02:25 | SEPARATE APPLICATION AND PERMIT REQUIRED. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2013-05-03 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-05-03 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-05-03 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-07-29 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-07-29 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-07-29 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2013-07-29 08:27:35 | APPROVED FOR DEMOLITION. NOT A HISTORIC RESOURCE. | | | QUESTIONS CONTACT FRIEDERIKE MITTNER 822-1457. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2013-07-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-07-10 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-06-28 |
Time |
17:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-06-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-06-26 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-06-14 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2013-06-15 09:55:08 | INCOMING SENT TO C-35 BOX . JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-06-05 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-06-05 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-05 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2013-04-26 14:41:57 | SENT TO C31 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-24 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-04-18 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-02-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-02-01 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-12-05 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2013-06-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-06-26 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-06-26 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2013-06-26 11:33:33 | PASS PROVISO | | | 1) SEPARATE PERMITS REQUIRED FOR UNDER GROUND FUEL | | | TANKS | | | HOOD,COOLERS AND GENERATOR. | | | 2) REVISION REQUIRED FOR AIR CONDITIONING AND | | | VENTILATION | | | IN IT ROOM 3.23 AND 3.36 2ED FLOOR AND DATA CENTER ROOM | | | 4.20 | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2013-06-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-06-04 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-06-04 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2013-06-04 10:53:13 | PLANS DENIED | | | 1) PROVIDE PRODUCT APPROVALS FOR OUTSIDE LOVERS | | | PER SECTION 106.3.3 2007 FBC | | | 2) PROVIDE FRESH AIR CALCULATION ON THE PLANS | | | PER TABLE 403.3 FBC (M) | | | 3) PROVIDE A DETAIL BY THE ENGINEER SHOWING | | | CONDENSER STAND TO ROOF TIEDOWN.(BOLT OR SCREW SIZE) | | | 4) REFER TO SECTION 306.1 CLEARANCE FOR MAINTENANCE AND | | | REPLACEMENT | | | FOR VOLUME AND FIRE DAMPERS. | | | 5) PROVIDE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR | | | FIRE DAMPERS | | | 6) SEPARATE APPLICATION PLANS AND PERMIT REQUIRED FOR | | | HOOD, COOLERS & FREEZERS, GENERATOR AND FUEL TANK | | | 7) IN RESUBMITTING PLANS REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2012-05-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-05-21 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-05-21 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2012-05-21 13:24:13 | PLANS DENIED | | | 1) PROVIDE PRODUCT APPROVALS FOR ALL OUTSIDE LOVERS . | | | PER SECTION 106.3.3 2007 FBC. | | | 2) PROVIDE FRESH AIR CALCULATIONS ON THE PLANS. | | | PER TABLE 403.3 2007 FBC (M) . | | | 3) PROVIDE A DETAIL ON THE PLANS SHOWING CONDENSER | | | STANDS | | | TO ROOF TIEDOWN. PER SECTION 3301.12. | | | 4) REFER TO SECTION 306.1 CLEARANCE FOR MAINTENANCE AND | | | REPLACEMENT. | | | FOR VOLUME DAMPERS.2007 FBC (M) . | | | 5) REFER TO SECTION 304.1 GENERAL 2007 FBC (M) PROVIDE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR FIRE | | | DAMPERS. | | | 6) REFER TO SECTION 607.4 ACCESS AND IDENTIFICATION. | | | 2007 FBC (M) FOR FIREDAMPERS. | | | 7) SEPARATE APPLICATION AND PLANS REQUIRED FOR HOODS, | | | FREEZERS COOLERS | | | AND GENERATOR. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-01-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-01-03 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-01-03 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2012-01-03 13:54:13 | PLANS DENIED | | | 1) PROVIDE PRODUCT APPROVALS FOR ALL OUTSIDE LOVERS PER | | | SECTION 106.3.3 2007 FBC. | | | 2) PROVIDE FRESH AIR CALCULATIONS ON THE PLANS PER | | | TABLE 403.3 . 2007 FBC (M) | | | 3) PROVIDE DUCT SIZE FOR RETURN AIR ON THE PLANS. NECK | | | SIZE ON AIR DISTRIBUTION SCHEDULE | | | PAGE M-6.01 AND THE PLANS DO NOT MATCH. | | | 4) SHOW RATED WALLS ON THE MECHANICAL PLANS. | | | 5) PROVIDE A DETAIL ON THE PLANS FOR THE CONDENSER | | | STAND TO ROOF TIE DOWN, | | | A THE CONDENSER TO STAND TIE DOWN. PER SECTION 301.12 | | | FBC (M) 2007 | | | 6) PROVIDE ON THE PLANS THE LOCATION AND TERMINATION OF | | | THE GENERATOR | | | EXHAUST PIPE. | | | 7) PROVIDE A DETAIL FOR ACCESS DOORS FOR VOLUME DAMPERS | | | ON THE PLANS. | | | PER SECTION 603.17 2007 FBC (M) | | | 8) PROVIDE MANUFACTURER'S INSTALLATION INSTRUCTIONS ON | | | THE FIRE DAMPERS. PER SECTION | | | 607.2 2007 FBC (M) . REFER TO SECTION B607.4 ACCESS AND | | | IDENTIFICATION. | | | 9) PROVIDE ENERGY CALCULATIONS WITH THE PLANS. | | | 10 PROVIDE EQUIPMENT SCHEDULE FOR IT ROOM AND MIS DATA | | | ROOM ON THE PLANS | | | 11 REFER TO SECTION 304.10 GUARDS FOR CONDENSERS ON | | | ROOF. | | | 12 SEPARATE APPLICATION PLANS AND PERMIT REQUIRED FOR | | | HOOD & COOLERS. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2013-07-05 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-07-05 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-07-05 |
Time |
07:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2013-06-25 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-06-25 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-06-25 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2013-06-25 13:21:06 | ***PROVISO*** | | | | | | 1. ENGINEERING WILL REVIEW WATER STORAGE TANK DUE TO A | | | CONCERN OVER A DEAD END SPACE IN THE TANK. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2013-05-03 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-05-03 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-05-03 |
Time |
10:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2012-05-09 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-05-09 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-05-08 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2012-05-09 13:22:00 | FBC 2007 PLUMBING REVIEW #2 | | | DENIED: | | | | | | NO RESPONSE WAS FOUND FOR REVIEW #1: | | | | | | 1. SHEET A-1.06 (1) - SHOWS AN ALUMINUM DOWNSPOUT | | | CONCEALED IN A CHASE. | | | 1A - SHEET A-4.13 & A-416 SHOW ALUMINUM DOWNSPOUT | | | UNDERGROUND WITH THE ADAPTER U/G ? | | | 1B - IF ALUMINUM LEADER LEAKS DOES CHASE FILL WITH | | | WATER? | | | 1C - P-7.01 SHOWS A DOWNSPOUT BOOT DETAIL THAT IS OK | | | BUT NOT THE SAME AS A-4.13 - A-4.16, AS IT IS EXPOSED | | | OUTSIDE: | | | 1102.2 INSIDE STORM DRAINAGE CONDUCTORS. INSIDE STORM | | | DRAINAGE CONDUCTORS INSTALLED ABOVE GROUND SHALL | | | CONFORM TO ONE OF THE STANDARDS LISTED IN TABLE 702.1. | | | | | | 2. A SERARATE RPZ BACKFLOW PREVENTOR OR AIR GAP WILL BE | | | REQUIRED FOR THE IRIGATION CISTERN MAKEUP WATER . | | | | | | 4. THE ELEVATOR PUMP WILL BE REQUIRED TO BE PIPED | | | INDIRECT INTO THE SANITARY DUE TO THE POSSIBILITY OF | | | CONTAMINANTS BEING SENT TO THE GROUND WATER. AN OIL | | | SENSOR/PUMP CONTROL/ALARM SYSTEM MAY BE OF HELP IN | | | KEEPING OIL OUT OF THE SANITARY SEWER. | | | SEC. 90-203. - PROHIBITED DISCHARGES; ILLICIT | | | CONNECTIONS. (A) | | | GENERAL PROHIBITION. EXCEPT AS PROVIDED IN SECTION | | | 90-205, AND EXCEPT PURSUANT TO A VALID NPDES PERMIT, IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO DIRECTLY OR | | | INDIRECTLY DEPOSIT, DISCHARGE, SPILL, OR DUMP INTO ANY | | | OF THE PUBLIC WATERS OR MUNICIPAL SEPARATE STORM SEWER | | | SYSTEM WITHIN THE CITY, ANY SUBSTANCE OTHER THAN THAT | | | COMPOSED ENTIRELY OF STORMWATER. | | | | | | 5. SHEET P-1.01 - 750 GALLON GREASE TRAP HAS 3" OUTLET | | | PIPEING. OUTLET PIPEING SHALL BE 4" MINIMUM: | | | 1003.5.3 INLET AND OUTLET PIPING. ....THE OUTLET PIPE | | | SHALL START AT 8 INCHES (203 MM) ABOVE THE BOTTOM OF | | | THE INTERCEPTOR AND EXTEND VERTICALLY TO A TEE. THE TEE | | | AND PIPE SHALL BE NO LESS THAN 4 INCHES (102 MM) IN | | | DIAMETER. THE TEE SHALL BE INSTALLED WITH THE RUN IN | | | THE VERTICAL DIRECTION. | | | | | | 6. SHEET P-1.01 (P-5.01) TRENCH AND FLOOR DRAINS HAVE | | | HORIZONTAL DRY VENT UNDER FLOOR: | | | 905.4 VERTICAL RISE OF VENT. EVERY DRY VENT SHALL RISE | | | VERTICALLY TO A MINIMUM OF 6 INCHES (152 MM) ABOVE THE | | | FLOOD LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE | | | BEING VENTED. | | | | | | EXCEPTION: VENTS FOR INTERCEPTORS LOCATED OUTDOORS. | | | ***NOTE*** THE FLOOR DRAINS CAN BE CONSIDERED | | | COMBINATION DRAIN AND VENT, THEREFORE NOT REQUIRING THE | | | DRY VENTS UNDER SLAB. | | | | | | ------------------------------------------------------- | | | ------------------------------------------------------ | | | NOTE | | | 1. ENGINEERING WILL REVIEW WATER STORAGE TANK DUE TO A | | | CONCERN OVER A DEAD END SPACE IN THE TANK. | | | 2. FUEL GAS & LANDSCAPE IRRIGATION ARE NOT PART OF THIS | | | REVIEW. SEPARATE PLANS, APPLICATION, FEES, AND PERMIT | | | REQUIRED | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-12-21 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-12-21 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-12-16 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2011-12-20 12:44:34 | FBC 2007 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. SHEET A-1.06 (1) - SHOWS AN ALUMINUM DOWNSPOUT | | | CONCEALED IN A CHASE. | | | 1A - SHEET A-4.13 & A-416 SHOW ALUMINUM DOWNSPOUT | | | UNDERGROUND WITH THE ADAPTER U/G ? | | | 1B - IF ALUMINUM LEADER LEAKS DOES CHASE FILL WITH | | | WATER? | | | 1C - P-7.01 SHOWS A DOWNSPOUT BOOT DETAIL THAT IS OK | | | BUT NOT THE SAME AS A-4.13 - A-4.16, AS IT IS EXPOSED | | | OUTSIDE: | | | 1102.2 INSIDE STORM DRAINAGE CONDUCTORS. INSIDE STORM | | | DRAINAGE CONDUCTORS INSTALLED ABOVE GROUND SHALL | | | CONFORM TO ONE OF THE STANDARDS LISTED IN TABLE 702.1. | | | | | | 2. A SERARATE RPZ BACKFLOW PREVENTOR OR AIR GAP WILL BE | | | REQUIRED FOR THE IRIGATION CISTERN MAKEUP WATER . | | | | | | 4. THE ELEVATOR PUMP WILL BE REQUIRED TO BE PIPED | | | INDIRECT INTO THE SANITARY DUE TO THE POSSIBILITY OF | | | CONTAMINANTS BEING SENT TO THE GROUND WATER. AN OIL | | | SENSOR/PUMP CONTROL/ALARM SYSTEM MAY BE OF HELP IN | | | KEEPING OIL OUT OF THE SANITARY SEWER | | | | | | 5. SHEET P-1.01 - 750 GALLON GREASE TRAP HAS 3" OUTLET | | | PIPEING. OUTLET PIPEING SHALL BE 4" MINIMUM: | | | 1003.5.3 INLET AND OUTLET PIPING. ....THE OUTLET PIPE | | | SHALL START AT 8 INCHES (203 MM) ABOVE THE BOTTOM OF | | | THE INTERCEPTOR AND EXTEND VERTICALLY TO A TEE. THE TEE | | | AND PIPE SHALL BE NO LESS THAN 4 INCHES (102 MM) IN | | | DIAMETER. THE TEE SHALL BE INSTALLED WITH THE RUN IN | | | THE VERTICAL DIRECTION. | | | | | | 6. SHEET P-1.01 (P-5.01) TRENCH AND FLOOR DRAINS HAVE | | | HORIZONTAL DRY VENT UNDER FLOOR: | | | 905.4 VERTICAL RISE OF VENT. EVERY DRY VENT SHALL RISE | | | VERTICALLY TO A MINIMUM OF 6 INCHES (152 MM) ABOVE THE | | | FLOOD LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE | | | BEING VENTED. | | | | | | EXCEPTION: VENTS FOR INTERCEPTORS LOCATED OUTDOORS. | | | ***NOTE*** THE FLOOR DRAINS CAN BE CONSIDERED | | | COMBINATION DRAIN AND VENT, THEREFORE NOT REQUIRING THE | | | DRY VENTS UNDER SLAB. | | | ------------------------------------------------------- | | | ------------------------------------------------------- | | | ------------------------------------------------------- | | | ------------------------------ | | | NOTE | | | 1. ENGINEERING WILL REVIEW WATER STORAGE TANK DUE TO A | | | CONCERN OVER A DEAD END SPACE IN THE TANK. | | | 2. FUEL GAS & LANDSCAPE IRRIGATION ARE NOT PART OF THIS | | | REVIEW. SEPARATE PLANS, APPLICATION, FEES, AND PERMIT | | | REQUIRED | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2013-07-01 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-07-01 |
Time |
19:32 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-07-01 |
Time |
19:32 |
Sent To |
|
|
| Notes |
| 2013-07-01 19:33:02 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 07.01.2013 | | | PERMIT NO.: 11120073 | | | ADDRESS: 700 CONGRESS AVENUE | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW FIRE STATION AND EMERGENCY | | | OPERATION CENTER. | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | | A UNITY OF TITLE SHALL BE RECORDED IN THE PUBLIC | | | RECORDS OF PALM BEACH COUNTY UNIFYING THE PARCEL | | | ACQUIRED FROM THE RESIDENTIAL PROPERTY TO THE SOUTH TO | | | THE FIRE STATION PARCEL. PLEASE CONTACT VINCE NOEL, | | | CITY SURVEYOR, AND PROVIDE ME WITH A COPY OF THE | | | RECORDED DOCUMENT. | | | | | | 2. PLEASE NOTE THAT A SEPARATE PERMIT WILL BE REQUIRED | | | FOR LANSCAPING. 2 SETS OF SIGNED/SEALED LANDSCAPE PLANS | | | SHALL BE SUBMITTED WITH A PERMIT APPLICATION, ALONG | | | WITH A CERTIFIED COST ESTIMATE (INCLUDING MATERIALS AND | | | LABOR). | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2013-06-20 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-06-20 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-06-20 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2013-06-20 10:39:22 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 06.20.2013 | | | PERMIT NO.: 11120073 | | | ADDRESS: 700 NORTH CONGRESS AVENUE | | | CONTRACTOR/CONTACT: VIVEK GALAV | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW FIRE STATION AND EMERGENCY | | | OPERATIONS CENTER. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE FOLLOWING PLANS HAVE NOT BEEN UPDATED: | | | | | | A. COVER | | | B. SP-1 | | | C. L1.1 | | | D. L1.2 | | | E. L1.3 | | | | | | 2. REPEAT COMMENT: THE NAME OF THE ENGINEERING SERVICES | | | DIRECTOR IS INCORRECT. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 3. REPEAT COMMENT: CONSIDER REMOVING WHEEL STOPS FROM | | | NORTHERN MOST PARKING AND SHIFT CURB TO SERVE AS WHEEL | | | STOP. THIS WAS DONE ON SOME OF THE PARKING, BUT NOT IN | | | THE "FIRE STATION STAFF PARKING LOT"...PLEASE EXPLAIN. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 4. REPEAT COMMENT: PLEASE PROVIDE THE SETBACK FROM THE | | | PROPERTY LINE TO THE FREESTANDING SIGN. IT SHALL BE 5 | | | FEET FROM THE RIGHT-OF-WAY, AND 24 FEET FROM ADJACENT | | | PROPERTY LINES. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 5. REPEAT COMMENT: PLEASE NOTE ON THE LANDSCAPE PLANS | | | THAT ALL LANDSCAPE AREAS IN THE PUBLIC RIGHT-OF-WAY | | | SHALL BE SODDED AND IRRIGATED. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 6. REPEAT COMMENT: IRRIGATION SHALL PROVIDE 120% | | | COVERAGE. | | | | | | 7. REPEAT COMMENT: PLEASE NOTE THAT A SEPARATE PERMIT | | | WILL BE REQUIRED FOR LANSCAPING. 2 SETS OF | | | SIGNED/SEALED LANDSCAPE PLANS SHALL BE SUBMITTED WITH A | | | PERMIT APPLICATION, ALONG WITH A CERTIFIED COST | | | ESTIMATE (INCLUDING MATERIALS AND LABOR). | | | | | | 8. A UNITY OF TITLE SHALL BE RECORDED IN THE PUBLIC | | | RECORDS OF PALM BEACH COUNTY UNIFYING THE PARCEL | | | ACQUIRED FROM THE RESIDENTIAL PROPERTY TO THE SOUTH TO | | | THE FIRE STATION PARCEL. PLEASE CONTACT VINCE NOEL, | | | CITY SURVEYOR, AND PROVIDE ME WITH A COPY OF THE | | | RECORDED DOCUMENT. | | | | | | 9. PLEASE ENSURE THAT THE UPDATED SITE PLANS REMOVE THE | | | "PROPOSED ACQUISITION" LABEL FROM THE PLANS AND THAT | | | THE CMU FENCE/WALL THAT WAS LOCATED ALONG THE SOUTHERN | | | PORTION OF THE ACQUIRED PARCEL IS REMOVED FROM THE | | | PLANS AND NO LONGER INCLUDED IN THE SCOPE OF THE | | | PROJECT. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | | | | 5/3/13 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2013-06-03 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-06-03 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-06-03 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2013-06-03 16:04:52 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 06.03.2013 | | | PERMIT NO.: 11120073 | | | ADDRESS: 700 NORTH CONGRESS AVENUE | | | CONTRACTOR/CONTACT: VIVEK GALAV | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW FIRE STATION AND EMERGENCY | | | OPERATIONS CENTER. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE FOLLOWING PLANS HAVE NOT BEEN UPDATED: | | | | | | A. COVER | | | B. SP-1 | | | C. L1.1 | | | D. L1.2 | | | E. L1.3 | | | | | | 2. REPEAT COMMENT: THE NAME OF THE ENGINEERING SERVICES | | | DIRECTOR IS INCORRECT. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 3. REPEAT COMMENT: CONSIDER REMOVING WHEEL STOPS FROM | | | NORTHERN MOST PARKING AND SHIFT CURB TO SERVE AS WHEEL | | | STOP. THIS WAS DONE ON SOME OF THE PARKING, BUT NOT IN | | | THE "FIRE STATION STAFF PARKING LOT"...PLEASE EXPLAIN. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 4. REPEAT COMMENT: PLEASE PROVIDE THE SETBACK FROM THE | | | PROPERTY LINE TO THE FREESTANDING SIGN. IT SHALL BE 5 | | | FEET FROM THE RIGHT-OF-WAY, AND 24 FEET FROM ADJACENT | | | PROPERTY LINES. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 5. REPEAT COMMENT: PLEASE NOTE ON THE LANDSCAPE PLANS | | | THAT ALL LANDSCAPE AREAS IN THE PUBLIC RIGHT-OF-WAY | | | SHALL BE SODDED AND IRRIGATED. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 6. REPEAT COMMENT: IRRIGATION SHALL PROVIDE 120% | | | COVERAGE. | | | | | | 7. REPEAT COMMENT: PLEASE NOTE THAT A SEPARATE PERMIT | | | WILL BE REQUIRED FOR LANSCAPING. 2 SETS OF | | | SIGNED/SEALED LANDSCAPE PLANS SHALL BE SUBMITTED WITH A | | | PERMIT APPLICATION, ALONG WITH A CERTIFIED COST | | | ESTIMATE (INCLUDING MATERIALS AND LABOR). | | | | | | 8. A UNITY OF TITLE SHALL BE RECORDED IN THE PUBLIC | | | RECORDS OF PALM BEACH COUNTY UNIFYING THE PARCEL | | | ACQUIRED FROM THE RESIDENTIAL PROPERTY TO THE SOUTH TO | | | THE FIRE STATION PARCEL. PLEASE CONTACT VINCE NOEL, | | | CITY SURVEYOR, AND PROVIDE ME WITH A COPY OF THE | | | RECORDED DOCUMENT. | | | | | | 9. PLEASE ENSURE THAT THE UPDATED SITE PLANS REMOVE THE | | | "PROPOSED ACQUISITION" LABEL FROM THE PLANS AND THAT | | | THE CMU FENCE/WALL THAT WAS LOCATED ALONG THE SOUTHERN | | | PORTION OF THE ACQUIRED PARCEL IS REMOVED FROM THE | | | PLANS AND NO LONGER INCLUDED IN THE SCOPE OF THE | | | PROJECT. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | | | | 5/3/13 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2013-06-02 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-06-02 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-05-28 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2013-06-02 17:02:09 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 06.02.2013 | | | PERMIT NO.: 11120073 | | | ADDRESS: 700 NORTH CONGRESS AVENUE | | | CONTRACTOR/CONTACT: VIVEK GALAV | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW FIRE STATION AND EMERGENCY | | | OPERATIONS CENTER. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE SITE PLANS, LANDSCAPE PLANS, CIVIL PLANS, ETC. | | | ALL SHOW THE OLD BUILDING ORIENTATION. PLEASE ENSURE | | | THAT ALL CURRENT PLANS IN THE PERMIT PACKAGE MATCH WHAT | | | IS CURRENTLY PROPOSED. AT A MINIMUM, I KNOW THE | | | FOLLOWING SHEETS WERE NOT RESUBMITTED: | | | | | | A. COVER | | | B. SP-1 | | | C. L1.1 | | | D. L1.2 | | | E. L1.3 | | | F. A-0.02 | | | | | | 2. REPEAT COMMENT: THE NAME OF THE ENGINEERING SERVICES | | | DIRECTOR IS INCORRECT. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 3. REPEAT COMMENT: CONSIDER REMOVING WHEEL STOPS FROM | | | NORTHERN MOST PARKING AND SHIFT CURB TO SERVE AS WHEEL | | | STOP. THIS WAS DONE ON SOME OF THE PARKING, BUT NOT IN | | | THE "FIRE STATION STAFF PARKING LOT"...PLEASE EXPLAIN. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 4. REPEAT COMMENT: PLEASE PROVIDE THE SETBACK FROM THE | | | PROPERTY LINE TO THE FREESTANDING SIGN. IT SHALL BE 5 | | | FEET FROM THE RIGHT-OF-WAY, AND 24 FEET FROM ADJACENT | | | PROPERTY LINES. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 5. REPEAT COMMENT: PLEASE NOTE ON THE LANDSCAPE PLANS | | | THAT ALL LANDSCAPE AREAS IN THE PUBLIC RIGHT-OF-WAY | | | SHALL BE SODDED AND IRRIGATED. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 6. REPEAT COMMENT: IRRIGATION SHALL PROVIDE 120% | | | COVERAGE. | | | | | | I BELIEVE THIS WAS FIXED ON THE UPDATED SHEETS THAT | | | WERE NOT SUBMITTED. | | | | | | 7. REPEAT COMMENT: PLEASE NOTE THAT A SEPARATE PERMIT | | | WILL BE REQUIRED FOR LANSCAPING. 2 SETS OF | | | SIGNED/SEALED LANDSCAPE PLANS SHALL BE SUBMITTED WITH A | | | PERMIT APPLICATION, ALONG WITH A CERTIFIED COST | | | ESTIMATE (INCLUDING MATERIALS AND LABOR). | | | | | | 8. A UNITY OF TITLE SHALL BE RECORDED IN THE PUBLIC | | | RECORDS OF PALM BEACH COUNTY UNIFYING THE PARCEL | | | ACQUIRED FROM THE RESIDENTIAL PROPERTY TO THE SOUTH TO | | | THE FIRE STATION PARCEL. PLEASE CONTACT VINCE NOEL, | | | CITY SURVEYOR, AND PROVIDE ME WITH A COPY OF THE | | | RECORDED DOCUMENT. | | | | | | 9. PLEASE ENSURE THAT THE UPDATED SITE PLANS REMOVE THE | | | ?PROPOSED ACQUISITION? LABEL FROM THE PLANS AND THAT | | | THE CMU FENCE/WALL THAT WAS LOCATED ALONG THE SOUTHERN | | | PORTION OF THE ACQUIRED PARCEL IS REMOVED FROM THE | | | PLANS AND NO LONGER INCLUDED IN THE SCOPE OF THE | | | PROJECT. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | | | 2013-05-03 15:31:54 | 5/3/13 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2012-05-08 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-05-08 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-04-30 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2012-05-08 15:18:35 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 05.08.2012 | | | PERMIT NO.: 11120073 | | | ADDRESS: 700 NORTH CONGRESS AVENUE | | | CONTRACTOR/CONTACT: JEFF HALVERSON | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW FIRE STATION #5. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE | | | FORMAL SITE PLAN REVIEW SHALL BE APPROVED BY THE | | | DEVELOPMENT SERVICES DEPARTMEN - PLANNING DIVISION. | | | | | | 2. THERE WAS CONCERN REGARDING THE PLACEMENT OF THE GAS | | | GRILL UNDER THE SOLID ROOF, PLEASE CONFIRM THAT THE | | | BUILDING DIVISION HAS NO OBJECTION. | | | | | | 3. THE ENGINEERING SERVICES DIRECTOR LISTED ON COVER | | | SHEET IS INCORRECT. | | | | | | 4. PLEASE CLARIFY HOW THE GATED STAFF PARKING WILL | | | FUNCTION. WILL THERE BE A CARD-READER, REMOTE CONTROL, | | | ETC? | | | | | | 5. PARKING STALL DETAIL SHALL MEET MINIMUM CRITERIA (IE | | | PLACEMENT OF WHEEL STOP). | | | | | | 6. CONSIDER REMOVING WHEEL STOPS FROM NORTHERN MOST | | | PARKING AND SHIFT CURB TO SERVE AS WHEEL STOP. THIS WAS | | | DONE ON SOME OF THE PARKING, BUT NOT IN THE "FIRE | | | STATION STAFF PARKING LOT"....PLEASE EXPLAIN. | | | | | | 7. PLEASE PROVIDE DOCUMENTATION FROM THE ARCHITECT OF | | | RECORD THAT THE PROPOSED DEVELOPMENT WILL COMPLY WITH | | | THE LAWS OF HB7135, REQUIRING THAT PUBLIC BUILDINGS | | | ENTERED INTO DESIGN AFTER JULY 1, 2008, FOLLOW THE | | | GUIDELINES OF LEEDS OR OTHER GREEN BUILDING SYSTEMS, | | | INCLUDING GREEN GLOBES AND THE FLORIDA GREEN BUILDING | | | COALITION STANDARDS. | | | | | | 8. TWO COPIES OF THE APPROVED TRAFFIC CONCURRENCY SHALL | | | BE PROVIDED. | | | | | | 9. PLEASE CONFIRM THAT ALL DIESEL FUEL TANKS, LP TANKS, | | | AND POTABLE WATER STORAGE TANKS WILL BE LOCATED | | | UNDERGROUND. | | | | | | 10. PHOTOMETRIC LEVELS SHALL NOT EXCEED 0.5 WHEN | | | MEASURED IN A RESIDENTIAL ZONING DISTRICT. ADJUST THE | | | LEVELS ALONG THE EAST AND SOUTH PROPERTY LINES | | | ACCORDINGLY. | | | | | | 11. PLEASE PROVIDE THE SETBACK FROM THE PROPERTY LINE | | | TO THE FREESTANDING SIGN. IT SHALL BE 5 FEET FROM THE | | | RIGHT-OF-WAY, AND 24 FEET FROM ADJACENT PROPERTY LINES. | | | | | | 12. PLEASE NOTE ON THE LANDSCAPE PLANS THAT ALL | | | LANDSCAPE AREAS IN THE PUBLIC RIGHT-OF-WAY SHALL BE | | | SODDED AND IRRIGATED. | | | | | | 13. LIGHT POLES SHALL NOT BE LOCATED IN VEHICLE | | | OVERHANG. | | | | | | 14. IRRIGATION SHALL PROVIDE 120% COVERAGE. | | | | | | PLEASE NOTE THAT A SEPARATE PERMIT WILL BE REQUIRED FOR | | | LANSCAPING. 2 SETS OF SIGNED/SEALED LANDSCAPE PLANS | | | SHALL BE SUBMITTED WITH A PERMIT APPLICATION, ALONG | | | WITH A CERTIFIED COST ESTIMATE (INCLUDING MATERIALS AND | | | LABOR). | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 6 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1459 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-12-19 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2011-12-19 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2011-12-14 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2011-12-19 14:52:09 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 12.19.2011 | | | PERMIT NO.: 11120073 | | | ADDRESS: 700 NORTH CONGRESS AVENUE | | | CONTRACTOR/CONTACT: JEFF HALVERSON | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW FIRE STATION #5. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. ACCORDING TO CONVERSATIONS WITH JEFF HALVERSON ON | | | 12/19/2011, THE ORIENTATION OF THE BUILDING IS BEING | | | MODIFIED, ALTERING THE SITE AND LANDSCAPE PLANS IN | | | THEIR ENTIRETY. THEREFORE, NO COMPLETE REVIEW WAS | | | COMPLETED AT THIS TIME. UPON COMPLETION OF REVISED | | | PLANS, SUBMITTAL WILL NEED TO BE MADE TO THE PLANNING | | | DIVISION TO BE REVIEWED BY THE PLANS & PLATS REVIEW | | | COMMITTEE. A SITE PLAN APPROVAL SHALL BE OBTAINED PRIOR | | | TO THE ISSUANCE OF ANY BUILDING PERMIT. PLEASE NOTE | | | PREVIOUS PPRC COMMENTS WHEN REVISING THE PLANS. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
|