Plan Review Details - Permit 11120037
Plan Review Stops For Permit 11120037
Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2011-12-21 Cont ID  
Sent By lmartine Date 2011-12-13 Time 15:49 Rev Time 0.00
Received By lmartine Date 2011-12-13 Time 15:49 Sent To  
Notes
2011-12-21 15:52:57SEE APPROVAL STAMP ON PLANS FROM MANNY. LM

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-12-30 Cont ID  
Sent By lmartine Date 2011-12-30 Time 14:25 Rev Time 0.00
Received By lmartine Date 2011-12-22 Time 12:06 Sent To  
Notes
2011-12-22 12:06:44IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-12-21 Cont ID  
Sent By lmartine Date 2011-12-13 Time 15:49 Rev Time 0.00
Received By lmartine Date 2011-12-01 Time 16:24 Sent To  
Notes
2011-12-01 16:24:22TO ZONING BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2011-12-29 Cont ID  
Sent By eschneid Date 2011-12-29 Time 15:51 Rev Time 0.25
Received By eschneid Date 2011-12-29 Time 15:51 Sent To ENG
Notes
2011-12-28 11:40:26GIVEN TO LF

Review Stop Z ZONING
Rev No 1 Status F Date 2011-12-12 Cont ID  
Sent By eschneid Date 2011-12-12 Time 11:42 Rev Time 0.50
Received By eschneid Date 2011-12-08 Time 13:23 Sent To ENG
Notes
2011-12-12 12:17:21FAILED
  
 PLEASE RESPOND IN WRITING.
  
 1) SECTION 94-313(C)2 OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS REQUIRES THAT EACH DRIVEWAY
 OPENING BE TEN (10) FEET OR LESS IN WIDTH AT THE
 PROPERTY LINE. THE PLANS INDICATE THAT THE DRIVEWAY IS
 13 FEET WIDE AT THE PROPERTY LINE.
  
 2) SECTION 94-482(D)5 OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS REQUIRES THAT THE INTERIOR ARC
 OF THE CIRCULAR DRIVE HAVE A MINIMUM RADIUS OF FIVE (5)
 FEET. NO DIMENSION LINES ARE SHOWN ON THE PLAN.
  
 3) THE DRIVEWAY IS DEPICTED ON THE PLAN AS HAVING A SIX
 (6) FOOT WEST SETBACK FROM THE PROPERTY LINE, BUT THE
 PLANS SHOW THE DRIVEWAY CONSTRUCTED ABUTTING THE FIVE
 (5) FOOT UTILITY EASEMENT. PLEASE CLARIFY.
  
 4) THE PROPOSED DRIVEWAY PLAN IS INCONSISTENT WITH THE
 PLANS SUBMITTED WITH THE MAIN BUILDING PERMIT
 11010629). EX. THE NORTHERNMOST GARAGE DRIVEWAY WAS
 SHOWN AT 26.5 FEET WIDE AND THE DRIVEWAY PERMIT SHOWS A
 20 FOOT WIDE DRIVEWAY AND THE DRIVEWAY SHAPE IN-FRONT
 OF THE BUILDING IS DIFFERENT. WHICH PLAN IS CORRECT?
  
 5) IF THE BUILDING PERMIT PLAN IS CORRECT, PLEASE
 SUBMIT 2 COPIES OF THAT PLAN, AS ALL OF THE INFORMATION
 REQUIRED IN #1-3 ABOVE IS INCLUDED.
  
 6) PLEASE PROVIDE INFORMATION ON THE INSTALLATION
 METHOD OF THE PAVERS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  
  