| Plan Review Stops For Permit 11110361 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2011-11-16 |
|
|
Cont ID |
|
| Sent By |
jnguyen |
Date |
2011-11-16 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
jnguyen |
Date |
2011-11-16 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2011-11-16 13:45:32 | THE WARRANTY DEED (OFFICIAL RECORD BOOK 24815, PAGE | | | 1072) REFERENCED THE LEGAL DESCRIPTION UNIT OF "1-I-A" | | | AS PART OF THE ADDRESS, INSTEAD OF THE ACTUAL CONDO | | | UNIT ADDRESS AS 330 CLEMATIS ST # 117. AS A RESULT, I | | | UPDATED COMMUNITYPLUS TO THE NEW PROPERTY OWNER OF | | | THORNE DONNELLEY JR., DESPITE THE FACT THAT THE PAPA | | | WEB SITE HAS YET TO DISPLAY THIS PROPERTY TRANSACTION. | | | | | | JOHN NGUYEN | | | GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | PUBLIC UTILITIES DEPARTMENT | | | OFFICE: (561) 822-1239 | | | FAX: (561) 822-1249 | | | [email protected] | | | | | | | | | | | 2011-11-16 11:07:52 | OWNER HAS CHGD MAIL TO ADDR IS NOT IN FORMAT WE | | | NORMALLY USE FOR CITY FILES |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-12-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-12-19 |
Time |
11:38 |
Rev Time |
0.66 |
| Received By |
jwitmer |
Date |
2011-12-19 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2011-12-19 11:52:28 | BUILDING PROVISO: | | | 2007/09 FBC-B 712.6 | | | FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS OR ANY OTHER | | | WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE | | | EFFECTIVELY AND PERMANENTLY IDENTIFIED | | | WITH SIGNS OR STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. | | | SUCH IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: | | | "FIRE AND SMOKE BARRIER - PROTECT ALL OPENINGS." |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-11-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-11-29 |
Time |
09:14 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2011-11-28 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2011-11-29 09:13:29 | BUILDING PLAN REVIEW | | | PERMIT: 11110361 | | | ADD: 330 CLEMATIS ST SUITE 117 SEPERATE PERMIT FOR | | | SUITE #118 | | | CONT: MUNNA CONTRACTING & DEVELOPMENT | | | TEL: (561)371-7677 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET A-1 INDICATES WITH A NOTE DETAIL # 3 TO BE A | | | 1-HOUR TENANT SEPERATION WALL TO DECK ABOVE BUT THERE | | | IS NO SUCH DETAIL. | | | | | | 2) PLEASE PROVIDE THE FOLLOWING NOTATION ABOVE THE | | | CEILING ON RATED WALLS: "FIRE AND SMOKE BARRIER - | | | PROTECT ALL OPENINGS." 712.6 FIRE WALLS, FIRE BARRIERS, | | | FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR | | | ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS | | | SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH | | | SIGNS OR STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDENTIFICATION | | | SHALL BE ABOVE ANY DECORATIVE CEILING AND IN CONCEALED | | | SPACES. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-12-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2011-12-20 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2011-12-20 |
Time |
09:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-12-01 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-12-01 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-12-01 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2011-12-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-12-20 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-12-20 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2011-12-16 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-12-16 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-12-16 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2011-12-16 12:43:45 | 330 CLEMATIS STREET - SUITE #117 | | | PERMIT #11110361 | | | ROUND 2 REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE MECHANICAL PLAN SUBMITTED IS NOT SIGNED OR SEALED | | | BY THE ENGINEER AND THE ADDRESS DOES NOT MATCH THE | | | PERMIT APPLICATION OR OTHER CONSTRUCTION DOCUMENTS. | | | | | | EACH NEW SMOKE OR FIRE-RATED WALL/PARTITION SHALL BE | | | PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING | | | FIRE/SMOKE BARRIER-PROTECT ALL OPENINGS. CHARACTERS | | | SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN | | | WIDTH. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 | | | FEET ON CENTER. | | | | | | PENETRATIONS THROUGH A FIRE-RATED WALL ASSEMBLY SHALL | | | BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE. PROVIDE | | | FIRESTOP DETAILS INDICATING THE MATERIALS AND METHODS | | | USED TO MAINTAIN THE FIRE RATED LISTING OF THE WALL. | | | | | | MODIFICATIONS SHOWN ON THE PLANS WILL AFFECT THE | | | EXISTING FIRE SPRINKLER AND FIRE ALARM SYSTEM. SEPARATE | | | PLANS AND PERMITS ARE REQUIRED FOR THE MODIFICATION OF | | | THE FIRE SPRINKLER SYSTEM AND FIRE ALARM SYSTEM. THE | | | PLANS ONLY INDICATE ONE FIRE ALARM STROBE APPLIANCE. | | | SPRINKLER SPACING INDICATES COVERAGES GREATER THAN 130 | | | SQUARE FEET (THE MAXIMUM ALLOWED FOR ORDINARY HAZARD). | | | NO SPRINKLER PROTECTION PROVIDED IN TWO RESTROOMS. | | | SEVERAL SPRINKLERS LOCATED MORE THAN 7'-6" FROM WALLS. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF | | | THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-11-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-11-29 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-11-29 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2011-11-29 13:53:46 | 330 CLEMATIS STREET - SUITE #117 | | | PERMIT #11110361 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PROVIDE SUITE NUMBER IN ADDRESS TITLEBLOCK. | | | | | | EACH NEW SMOKE OR FIRE-RATED WALL/PARTITION SHALL BE | | | PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING | | | FIRE/SMOKE BARRIER-PROTECT ALL OPENINGS. CHARACTERS | | | SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN | | | WIDTH. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 | | | FEET ON CENTER. PENETRATIONS THROUGH A FIRE-RATED WALL | | | ASSEMBLY SHALL BE PROTECTED BY A FIRESTOP SYSTEM OR | | | DEVICE. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF | | | THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | MODIFICATIONS SHOWN ON THE PLANS WILL AFFECT THE | | | EXISTING FIRE SPRINKLER AND FIRE ALARM SYSTEM. SEPARATE | | | PLANS AND PERMITS ARE REQUIRED FOR THE MODIFICATION OF | | | THE FIRE SPRINKLER SYSTEM AND FIRE ALARM SYSTEM. THE | | | PLANS ONLY INDICATE ONE FIRE ALARM STROBE APPLIANCE. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-12-20 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-12-20 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-12-14 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2011-12-14 09:34:05 | ****************EXPEDITED***************** | | | B--5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-12-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-12-12 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-11-17 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-12-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-12-15 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-12-15 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-12-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-12-12 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-12-12 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2011-12-12 14:57:48 | PLANS DENIED. | | | 1) PROVIDE THE LOCATION FOR THE CONDENSATE LINE ON THE | | | PLANS. | | | 2) PROVIDE FRESH AIR CALCULATIONS ON THE PLANS. | | | 3) REFER TO SECTION 606.2.1 SUPPLY AIR AND 606.3 | | | INSTALLATION. | | | 2007 FBC (M) | | | 4) REFER TO SECTION 606.4.1 SUPERVISION 2007 FBC (M) | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2011-12-15 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-12-15 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-12-15 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2011-12-15 11:50:52 | NO PLUMBING WORK AT THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-12-02 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-12-02 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-12-02 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2011-12-02 13:43:15 | FBC 2007 PLUMBING REVIEW #1 | | | DENIED: | | | | | | THE PATH OF TRAVEL TO THE RESTROOMS IS NOT COMPLIANT | | | WITH PLUMBING 403.4 IN ONE STORE IT IS THROUGH A | | | STORAGE ROOM AND THE OTHER IS THROUGH A BREAK ROOM: | | | | | | 403.4 REQUIRED PUBLIC TOILET FACILITIES. CUSTOMERS, | | | PATRONS AND VISITORS SHALL BE PROVIDED WITH PUBLIC | | | TOILET FACILITIES IN STRUCTURES AND TENANT SPACES | | | INTENDED FOR PUBLIC UTILIZATION. THE ACCESSIBLE ROUTE | | | TO PUBLIC FACILITIES SHALL NOT PASS THROUGH KITCHENS, | | | STORAGE ROOMS, CLOSETS OR SIMILAR SPACES. EMPLOYEES | | | SHALL BE PROVIDED WITH TOILET FACILITIES IN ALL | | | OCCUPANCIES. EMPLOYEE TOILET FACILITIES SHALL BE EITHER | | | SEPARATE OR COMBINED EMPLOYEE AND PUBLIC TOILET | | | FACILITIES. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-12-06 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2011-12-06 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2011-12-06 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2011-12-06 14:59:39 | PROVISO: | | | 1. ACCORDING TO SECTION 94-105 (D)(1)D - ALONG CLEMATIS | | | STREET, RETAIL USES SHALL OCCUPY THE MINIMUM REQUIRED | | | ACTIVE USE LINER DEPTH OF 25 FEET. MERCHANDISE OR FOOD | | | SALES SHALL REPRESENT A MINIMUM OF 50% OF BUSINESS | | | REVENUE AT REQUIRED RETAIL FRONTAGES. | | | 2. NO RETAIL USES MAY OCCUPY THE SPACE BEHIND THE | | | MINIMUM 25 FEET ACTIVE USE LINER, BUT RETAIL SPACE | | | SHALL BE SEPARATED FROM THE OTHER USES BY A DEMISING | | | WALL. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE |
|
|