| Plan Review Stops For Permit 11110301 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2012-01-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2012-01-27 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-01-27 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-12-30 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-12-30 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-12-30 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2011-12-30 10:39:05 | PREVIOUS COMMENTS WERE NOT ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-12-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-12-01 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-12-01 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2011-12-01 16:08:41 | BUILDING REVIEW COMMENTS | | | | | | | | | | | | PROVIDE WIND LOAD ANALYSIS FOR THE OPENINGS ON THE | | | BUILDING. THE DOOR SPEC'S SUBMITTED ARE ONLY GOOD FOR | | | -70 PSF. | | | | | | SUBMIT DOCUMENTION CERTIFYING A 1HR ASSEMBLY, | | | | | | | | | LUIS MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2012-01-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-01-20 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-01-20 |
Time |
13:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2011-12-19 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-12-19 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-12-19 |
Time |
11:46 |
Sent To |
B |
|
| Notes |
| 2011-12-19 12:17:07 | 525 SOUTH FLAGLER DRIVE | | | PERMIT #11110301 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | DOORS SHALL HAVE A FIRE RATING OF AT LEAST 90-MINUTES | | | WHEN LOCATED IN A TWO-HOUR FIRE-RATED STAIR SHAFT. | | | | | | FIRE DOORS SHALL MEET THE REQUIREMENTS OF NFPA 80. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-12-01 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-12-01 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-12-01 |
Time |
10:56 |
Sent To |
B |
|
| Notes |
| 2011-12-01 11:03:40 | 525 SOUTH FLAGLER DRIVE | | | PERMIT #11110301 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PLANS AND PERMIT APPLICATION INDICATE THE REPLACEMENT | | | OF FIRE DOORS. NO HOURLY FIRE PROTECTION RATING COULD | | | BE FOUND ON THE INFORMATION SUBMITTED. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-01-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2012-01-27 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-01-10 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2012-01-10 16:43:22 | TO FIRE BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-12-30 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-12-30 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-12-13 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2011-12-21 15:04:47 | TO LM DESK | | | | | 2011-12-13 16:19:52 | SENT TO FIRE BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-12-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-12-01 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-11-14 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2011-11-14 14:37:01 | TO FIRE BOX |
|
|