Plan Review Details - Permit 11110025
Plan Review Stops For Permit 11110025
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2011-11-16 Cont ID  
Sent By jwitmer Date 2011-11-16 Time 09:10 Rev Time 1.30
Received By jwitmer Date 2011-11-16 Time 08:07 Sent To  
Notes
2011-11-16 09:25:15BUILDING PROVISO:
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR
 TO INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND
 THE ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS
 REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
 PLEASE SEE HIGHLIGHTED AREAS ON SHEET 1-3 ARE EXISTING
 NON-CODE COMPLIANT (FBC-B 11-4.13.6) DOORS.
 2007/09 EXST. BLDG. CODE LEVEL II ALTERATIONS SECTION
 706.1. A BUILDING, FACILITY, OR ELEMENT THAT IS
 ALTERED SHALL COMPLY WITH CHAPTER 11 OF THE FLORIDA
 BUILDING CODE, BUILDING .
  
 2007/09 FBC-B 11-4.1.6(2) (2) ALTERATIONS TO AN AREA
 CONTAINING A PRIMARY FUNCTION.
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO ALTERED AREAS SHALL BE DEEMED
 DISPROPORTIONATE
 TO THE OVERALL ALTERATION WHEN THE COST EXCEEDS 20
 PERCENT OF THE COST OF THE ALTERATION TO THE PRIMARY
 FUNCTION AREA.
 DUTY TO PROVIDE ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
 (1) WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE
 PATH OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT
 IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS.
 (2)(A) IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO
 PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE ELEMENTS
 THAT WILL PROVIDE
 THE GREATEST ACCESS, IN THE FOLLOWING ORDER:
 (I) AN ACCESSIBLE ENTRANCE;
 (II) AN ACCESSIBLE ROUTE TO THE ALTERED AREA:
 (III) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR
 A SINGLE UNISEX RESTROOM:
 (IV) ACCESSIBLE TELEPHONES;
 (V) ACCESSIBLE DRINKING FOUNTAINS; AND
 (VI) WHEN POSSIBLE, ADDITIONAL ACCESSIBLE ELEMENTS SUCH
 AS PARKING, STORAGE, AND ALARMS.
  
 PLEASE PROVIDE ADDITIONAL INFORMATION WHERE THE 20%
 ADDITIONAL FUNDS WILL BE SPENT IN CREATING AN CODE
 COMPLIANT ACCESSIBLE
 SPACE BY FRAMING INSPECTION.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-11-03 Cont ID  
Sent By rlecky Date 2011-11-03 Time 12:09 Rev Time 0.00
Received By rlecky Date 2011-11-03 Time 12:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-11-08 Cont ID  
Sent By wjolin Date 2011-11-08 Time 11:54 Rev Time 0.00
Received By wjolin Date 2011-11-08 Time 11:20 Sent To  
Notes
2011-11-08 11:54:11222 LAKEVIEW AVENUE - SUITE #800W
 PERMIT #11110025
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE INTERIOR FINISH MATERIALS OF WALLS AND CEILINGS FOR
 EXIT ACCESS CORRIDORS SHALL MEET THE SMOKE DEVELOPMENT
 (0-450) AND FLAME SPREAD (0-75) REQUIREMENTS FOR CLASS
 A & B INTERIOR FINISHES PER NFPA 101.
  
 SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 MODIFICATION OF THE FIRE SPRINKLER SYSTEM AND FIRE
 ALARM SYSTEM.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-11-16 Cont ID  
Sent By lwagner Date 2011-11-16 Time 10:44 Rev Time 0.00
Received By lwagner Date 2011-11-02 Time 13:26 Sent To  
Notes
2011-11-02 13:26:46C22

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-11-16 Cont ID  
Sent By jwitmer Date 2011-11-16 Time 09:26 Rev Time 0.20
Received By jwitmer Date 2011-11-16 Time 09:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-11-16 Cont ID  
Sent By lwagner Date 2011-11-16 Time 10:44 Rev Time 0.00
Received By lwagner Date 2011-11-16 Time 10:10 Sent To  
Notes
***NONE***