Plan Review Details - Permit 11100709
Plan Review Stops For Permit 11100709
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-11-09 Cont ID  
Sent By jgomez Date 2011-11-09 Time 16:29 Rev Time 0.00
Received By jgomez Date 2011-11-09 Time 16:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-10-31 Cont ID  
Sent By jgomez Date 2011-10-31 Time 15:02 Rev Time 0.00
Received By jgomez Date 2011-10-31 Time 14:58 Sent To  
Notes
2011-10-31 15:28:24RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR TILE TO BE
 INSTALLED AS REQUIRED BY DCA RULE 9N-3. NONE SUBMITTED
 AT THIS TIME.
  
 2- SPECIFY HOW IS THE TILE GOING TO BE INSTALLED. IF
 USING ADHESIVE, THEN CHECK TILE PRODUCT APPROVAL FOR
 LISTED ADHESIVES AND PROVIDE THE PRODUCT APPROVAL (2
 COPIES). IF USING NAILS/SCREWS, THEN PROVIDE THE UPLIFT
 CALCULATIONS AND NUMBER OF NAILS/SCREWS TO BE USED TO
 MEET SUCH UPLIFT PRESSURES.
  
 3- SPECIFY WHICH FLAT ROOF APPROVED ASSEMBLY IS GOING
 TO BE INSTALLED TO SHOW COMPLIANCE WITH THE DESIGN
 PRESSURES OF SEC. R301.2.1.4.3.
  
 4- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS
 REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA
 08-0410.09 SUBMITTED.
 DESIGN PROFESSIONAL DOING THE CALCULATIONS TO TAKE INTO
 CONSIDERATION THAT ACCORDING TO 2009 REVISIONS SEC.
 R301.2.1.4.3 THIS BUILDING IS LOCATED ON EXPOSURE "C".
  
 (NOTE: ASSEMBLIES WITH GENERAL LIMITATION #9 CAN'T BE
 USED IN THIS BUILDING. THEY DON'T MEET THE DESIGN
 PRESSURES).
  
 5- CLEARLY IDENTIFY HOW MUCH AREA IS FLAT AND HOW MUCH
 AREA IS TILE TO VERIFY COMPLIANCE WITH THE VALUE
 DECLARED IN THE PERMIT APPLICATION TO COMPLY WITH SEC.
 108.3 CITY AMENDMENTS TO FBC. SQUARE FOOTAGE SPECIFIED
 ON THE PERMIT APPLICATION IS TOO LOW COMPARED TO THE
 SQUARE FOOTAGE OF THE HOUSE SHOWN ON THE PROPERTY
 APPRAISAL WEBSITE.
  
 6- THE HOUSE VALUE IS MORE THAN $300.000. NEED TO
 PROVIDE ROOF TO WALL CONNECTIONS AS REQUIRED BY SEC.
 611.8 OF 2007 FBC- EXISTING BUILDING CODE.
  
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2011-10-31 Cont ID  
Sent By jpapa Date 2011-10-31 Time 14:36 Rev Time 0.00
Received By jpapa Date 2011-10-31 Time 14:36 Sent To  
Notes
2011-10-31 14:39:34PROVISO:
  
 THE PITCHED PORTION SHALL FEATURE A FULL BARREL TILE
 FINISHING MATERIAL. THE PALEMA/HAICEIENDA ROOF TILE
 PRODUCT SHALL NOT BE INSTALLED. THE FINISHING MATERIAL
 SHALL BE ADMINISTRATIVELY APPROVED PRIOR TO
 INSTALLATION.
  
 FOR MORE INFORMATION, PLEASE COTNACT JILLIAN PAPA,
 HISTORIC PRESERVATION PLANNER AT 561-822-1454.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-11-09 Cont ID  
Sent By jgomez Date 2011-11-09 Time 16:15 Rev Time 0.00
Received By jgomez Date 2011-11-09 Time 16:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-10-31 Cont ID  
Sent By jgomez Date 2011-10-31 Time 14:58 Rev Time 0.00
Received By jgomez Date 2011-10-31 Time 14:58 Sent To  
Notes
***NONE***