Plan Review Details - Permit 11100660
| Plan Review Stops For Permit 11100660 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-11-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-11-08 |
Time |
13:58 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2011-11-08 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-11-07 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-11-07 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-11-07 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2011-11-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-11-03 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-11-03 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2011-11-03 10:46:55 | 517 CLEMATIS STREET | | | PERMIT #11100660 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS | | | OF NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | | REMOVED FROM THE SITE DAILY. | | | | | | CONFIRM ONE EMERGENCY LIGHT FIXTURE IN DINING #102 WILL | | | PROVIDE ONE FOOT CANDLE OF LIGHT AT THE FLOOR ALONG THE | | | EGRESS PATH. | | | | | | GAS-FIRED PIZZA OVEN DOES NOT APPEAR TO BE LOCATED | | | BELOW THE COMMERCIAL COOKING HOOD. | | | | | | DEEP FAT FRYERS SHALL BE EQUIPPED WITH A SEPARATE | | | HIGH-LIMIT CONTROL IN ADDITION TO THE ADJUSTABLE | | | THERMOSTAT TO SHUT OFF FUEL OR ENERGY WHEN THE FAT | | | TEMPERATURE REACHES 475F DEGREES AT 1-INCH BELOW THE | | | SURFACE. | | | | | | ASSEMBLY ROOM SHALL HAVE THE OCCUPANT LOAD OF THE ROOM | | | POSTED IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM | | | THE ROOM. SIGNS SHALL BE DURABLE AND INDICATE THE | | | NUMBER OF OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | VERIFY EXISTING EXIT DOOR LOCK/LATCH RELEASING | | | MECHANISMS. NOTE: A THUMB TURN LOCK IS NOT PERMITTED ON | | | EXIT DOORS. THE MAIN ENTRY IS PERMITTED TO BE EQUIPPED | | | WITH A KEYED LOCK WITH LOCK/UNLOCK INDICATOR WINDOW AND | | | SIGNAGE STATING THE DOOR IS TO REMAIN UNLOCKED DURING | | | BUSINESS HOURS. NO OTHER LOCKING OR LATCHING MECHANISMS | | | ARE PERMITTED. | | | | | | SEPARATE PLANS AND PERMIT REQUIRED FOR COMMERCIAL HOOD | | | AND KITCHEN HOOD SUPPRESSION SYSTEM. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2011-11-03 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-11-03 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-11-03 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2011-11-03 13:55:01 | SEPARATE GAS APPLICATION, JOB VALUE, DRAWINGS, AND | | | PERMIT REQUIRED. | | | AN AUTOMATIC GAS VALVE WILL BE REQUIRED (BELOW CEILING | | | AND NOT UNDER GREASE HOOD). | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2011-12-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-10-28 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2011-11-17 11:21:48 | TO LUIS MARTINEZ | | 2011-10-28 12:22:22 | B--6 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2011-12-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-12-02 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-12-02 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2011-12-02 14:10:12 | **PROVISO** | | | | | | ROOF CAP DETAIL APPEARS TO BE FOR A WALL CAP AND NOT | | | SUITABLE FOR ROOFTOP INSTALLATION. ROOF CAP IS SUBTECT | | | TO FIELD INSPECTOR'S APPROVAL. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2011-11-03 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-11-03 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-11-03 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2011-11-03 13:54:36 | ****PROVISO**** | | | THE PLUMBING CONTRACTOR WILL VERIFY THE EXISTING | | | GREASE TRAP FOR SIZE, AND SOUNDNESS. IF GREASE TRAP | | | IS NOT EXISTING THEN A SEPARATE APPLICATION, PLAN, | | | AND PERMIT WILL BE REQUIRED FOR THE INSTALLATION. | | | | | | | | | SEPARATE GAS APPLICATION, JOB VALUE, DRAWINGS, AND | | | PERMIT REQUIRED. | | | AN AUTOMATIC GAS VALVE WILL BE REQUIRED (BELOW CEILING | | | AND NOT UNDER GREASE HOOD). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-11-17 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2011-11-17 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2011-11-17 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2011-11-17 11:21:21 | INTERIOR CHANGES TO CONVERT INTO RESTAURANT. |
|
|
|
Account Summary | Usage Policy | Privacy Policy