| 2011-12-05 17:57:12 | RESIDENTIAL RENOVATION BUILDING REVIEW COMMENTS. |
| | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| | |
| | 1- ACCORDING TO 2009 REVISIONS SEC. R301.2.1.4.3 THIS |
| | BUILDING IS LOCATED ON EXPOSURE "C" NO "B". PLEASE, |
| | REVISE CODE & DESIGN LOADS INFORMATION AND THE |
| | WINDOWS/DOORS DESIGN PRESSURES ON SHEET A01 OF 5. |
| | |
| | 2- PLEASE SPECIFY ON PLANS CARBON MONOXIDE ALARMS AS |
| | REQUIRED BY SEC. R313.4. |
| | |
| | 3- PLEASE SPECIFY SMOKE ALARMS ON PLANS AS REQUIRED BY |
| | SEC. R313.2.1. |
| | |
| | 4- PLEASE PROVIDE COMPLETE FRAMING DETAILS AND |
| | SPECIFICATIONS FOR THE NEW DOUBLE DOORS AND WINDOWS TO |
| | BE INSTALLED. SPECIFY ALL FRAMING MEMBERS SIZES AND |
| | FASTENERS AS REQUIRED TO MEET THE DESIGN LOADS OF SEC. |
| | R301. |
| | |
| | 5- PLEASE PROVIDE COMPLETE FRAMING DETAILS FOR EXTERIOR |
| | OPENINGS TO BE ENCLOSED AS SHOWN ON PLANS TO MEET THE |
| | DESIGN LOADS OF SEC. R301. |
| | |
| | 6- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) DOUBLE DOORS AS SHOWN ON PLANS. PRODUCT APPROVAL |
| | SUBMITTED IS FOR 8'-0" DOORS. NEED PRODUCT APPROVAL FOR |
| | SIZE SHOWN ON PLANS. |
| | |
| | B) WINDOW MULLIONS AS SHOWN ON PLANS. |
| | |
| | C) ALL STRUCTURAL CONNECTORS SPECIFIED BY THE ARCHITECT |
| | ON THE FRAMING DETAILS. PROVIDE ONLY THE COVER PAGE AND |
| | PAGE SHOWING THE CONNECTOR. |
| | |
| | D) FLAT ROOF AND/OR SHINGLES TO BE INSTALLED. SEE |
| | COMMENT #9 BELOW. |
| | |
| | 7- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. |
| | |
| | 8- NEW STEPS BY FLORIDA ROOM: A) PLEASE PROVIDE |
| | COMPLETE DIMENSIONS FOR THE LANDING AS REQUIRED BY SEC. |
| | R311.4.3. |
| | |
| | B) PLEASE SPECIFY RISER AND TREADS DIMENSIONS AS |
| | REQUIRED BY SEC. R311.5.3. |
| | |
| | 9- PLEASE CLARIFY SCOPE OF WORK TO BE DONE ON THE ROOF. |
| | OWNER IS APPLYING FOR A ROOFING PERMIT ALSO. ARE YOU |
| | RE-ROOFING THE HOUSE?. PLEASE COORDINATE WITH ITEM # |
| | 6(D) ABOVE. |
| | |
| | 10- SHEET A01 OF 5: A) PLEASE CLARIFY SCOPE OF WORK |
| | NOTE #2. PLANS DON'T SHOW ANY WORK DONE ON THE ENTRY |
| | WAY. SEC. 106.1.1 CITY AMENDMENTS. |
| | |
| | B) CLARIFY SCOPE OF WORK NOTE #4. PLANS DON'T SHOW ANY |
| | WORK SHOWING ADDITION OF NEW ENTRY PORTICO. SEC. |
| | 106.1.1 CITY AMENDMENTS. |
| | |
| | C) PLEASE REVISE THE PARCEL CONTROL NUMBER SHOWN ON THE |
| | LEGAL DESCRIPTION. NUMBER SHOWN IS INCORRECT. |
| | |
| | D) PLEASE CLARIFY/REVISE SQUARE FOOTAGES SHOWN AT THE |
| | BOTTOM LEFT OF THE PAGE. THIS NUMBERS DON'T MATCH FLOOR |
| | PLANS SUBMITTED AND INFORMATION SHOWN ON THE PALM BEACH |
| | COUNTY PROPERTY APPRAISER WEBSITE. WHERE IS THE |
| | EXISTING SCREEN PORCH?. |
| | |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561)805-6712 |