Plan Review Details - Permit 11100654
Plan Review Stops For Permit 11100654
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-12-13 Cont ID  
Sent By jgomez Date 2011-12-13 Time 11:29 Rev Time 0.00
Received By jgomez Date 2011-12-13 Time 10:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-12-05 Cont ID  
Sent By jgomez Date 2011-12-05 Time 16:47 Rev Time 0.00
Received By jgomez Date 2011-12-05 Time 15:04 Sent To  
Notes
2011-12-05 17:57:12RESIDENTIAL RENOVATION BUILDING REVIEW COMMENTS.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- ACCORDING TO 2009 REVISIONS SEC. R301.2.1.4.3 THIS
 BUILDING IS LOCATED ON EXPOSURE "C" NO "B". PLEASE,
 REVISE CODE & DESIGN LOADS INFORMATION AND THE
 WINDOWS/DOORS DESIGN PRESSURES ON SHEET A01 OF 5.
  
 2- PLEASE SPECIFY ON PLANS CARBON MONOXIDE ALARMS AS
 REQUIRED BY SEC. R313.4.
  
 3- PLEASE SPECIFY SMOKE ALARMS ON PLANS AS REQUIRED BY
 SEC. R313.2.1.
  
 4- PLEASE PROVIDE COMPLETE FRAMING DETAILS AND
 SPECIFICATIONS FOR THE NEW DOUBLE DOORS AND WINDOWS TO
 BE INSTALLED. SPECIFY ALL FRAMING MEMBERS SIZES AND
 FASTENERS AS REQUIRED TO MEET THE DESIGN LOADS OF SEC.
 R301.
  
 5- PLEASE PROVIDE COMPLETE FRAMING DETAILS FOR EXTERIOR
 OPENINGS TO BE ENCLOSED AS SHOWN ON PLANS TO MEET THE
 DESIGN LOADS OF SEC. R301.
  
 6- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) DOUBLE DOORS AS SHOWN ON PLANS. PRODUCT APPROVAL
 SUBMITTED IS FOR 8'-0" DOORS. NEED PRODUCT APPROVAL FOR
 SIZE SHOWN ON PLANS.
  
 B) WINDOW MULLIONS AS SHOWN ON PLANS.
  
 C) ALL STRUCTURAL CONNECTORS SPECIFIED BY THE ARCHITECT
 ON THE FRAMING DETAILS. PROVIDE ONLY THE COVER PAGE AND
 PAGE SHOWING THE CONNECTOR.
  
 D) FLAT ROOF AND/OR SHINGLES TO BE INSTALLED. SEE
 COMMENT #9 BELOW.
  
 7- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC.
  
 8- NEW STEPS BY FLORIDA ROOM: A) PLEASE PROVIDE
 COMPLETE DIMENSIONS FOR THE LANDING AS REQUIRED BY SEC.
 R311.4.3.
  
 B) PLEASE SPECIFY RISER AND TREADS DIMENSIONS AS
 REQUIRED BY SEC. R311.5.3.
  
 9- PLEASE CLARIFY SCOPE OF WORK TO BE DONE ON THE ROOF.
 OWNER IS APPLYING FOR A ROOFING PERMIT ALSO. ARE YOU
 RE-ROOFING THE HOUSE?. PLEASE COORDINATE WITH ITEM #
 6(D) ABOVE.
  
 10- SHEET A01 OF 5: A) PLEASE CLARIFY SCOPE OF WORK
 NOTE #2. PLANS DON'T SHOW ANY WORK DONE ON THE ENTRY
 WAY. SEC. 106.1.1 CITY AMENDMENTS.
  
 B) CLARIFY SCOPE OF WORK NOTE #4. PLANS DON'T SHOW ANY
 WORK SHOWING ADDITION OF NEW ENTRY PORTICO. SEC.
 106.1.1 CITY AMENDMENTS.
  
 C) PLEASE REVISE THE PARCEL CONTROL NUMBER SHOWN ON THE
 LEGAL DESCRIPTION. NUMBER SHOWN IS INCORRECT.
  
 D) PLEASE CLARIFY/REVISE SQUARE FOOTAGES SHOWN AT THE
 BOTTOM LEFT OF THE PAGE. THIS NUMBERS DON'T MATCH FLOOR
 PLANS SUBMITTED AND INFORMATION SHOWN ON THE PALM BEACH
 COUNTY PROPERTY APPRAISER WEBSITE. WHERE IS THE
 EXISTING SCREEN PORCH?.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-12-13 Cont ID  
Sent By rlecky Date 2011-12-13 Time 16:02 Rev Time 0.00
Received By rlecky Date 2011-12-13 Time 16:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-11-03 Cont ID  
Sent By rlecky Date 2011-11-03 Time 09:39 Rev Time 0.00
Received By rlecky Date 2011-11-03 Time 08:32 Sent To  
Notes
2011-11-03 09:40:1511100654
 1704 FLORIDA AVE.
 INTERIOR RENOVATION
  
 ADD SMOKE ALARMS AND CARBON MONOXIDE ALARMS. FBC R313
 ALL NEW BRANCH CIRCUITS MUST BE PROTECTED WITH ARC
 FAULT CIRCUIT INTERRUPTERS. NEC 210.12
 NEW RECEPTACLES MUST BE TAMPER RESISTANT NEC 406.11
 A BONDING STRIP IS REQUIRED AT SERVICE GROUND NEC
 250.94
 THE SITE PLAN SHOWS A GARAGE. IF THE SCOPE OF
 RECONSTRUCTION INCLUDES AN ELECTRICAL CONNECTION TO THE
 GARAGE FROM THE HOUSE THAN A SPECIFIC WIRING METHOD IS
 REQUIRED. NEC 250.32
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
 561-805-6718
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2012-07-10 Cont ID  
Sent By fmittner Date 2012-07-10 Time 09:04 Rev Time 0.00
Received By fmittner Date 2012-07-10 Time 09:04 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2011-11-01 Cont ID  
Sent By jpapa Date 2011-11-01 Time 13:12 Rev Time 0.00
Received By jpapa Date 2011-11-01 Time 13:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-12-15 Cont ID  
Sent By jgomez Date 2011-12-15 Time 14:35 Rev Time 0.00
Received By jgomez Date 2011-12-08 Time 13:25 Sent To  
Notes
2011-12-15 14:38:27STAMPING SECOND SET OF PLANS TO ISSUE PERMIT. ONLY ONE
 COPY SUBMITTED AT TIME OF RE-SUBMITTAL. JG.
2011-12-08 13:27:30R--7

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-12-06 Cont ID  
Sent By jgomez Date 2011-12-06 Time 09:59 Rev Time 0.00
Received By jgomez Date 2011-11-02 Time 10:28 Sent To  
Notes
2011-11-02 10:28:41R5

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2011-12-13 Cont ID  
Sent By jgomez Date 2011-12-13 Time 10:51 Rev Time 0.00
Received By jgomez Date 2011-12-13 Time 09:09 Sent To  
Notes
2011-12-13 10:52:20KEVIN PALMER SAID NO A/C WORK AT THIS TIME. HE SAID,
 OWNER WILL GET A/C PERMIT AT A LATER TIME.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-12-06 Cont ID  
Sent By jgomez Date 2011-12-06 Time 09:54 Rev Time 0.00
Received By jgomez Date 2011-12-06 Time 09:54 Sent To  
Notes
2011-12-06 09:58:14RESIDENTIAL RENOVATION MECHANICAL REVIEW COMMENTS.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PLEASE PROVIDE INFORMATION SHOWING A/C SCOPE OF WORK
 TO BE PERFORMED. PLANS SUBMITTED DON'T SHOW ANY WORK
 AND OWNER APPLIED FOR AN A/C PERMIT. SEC. 106.1.1 CITY
 AMENDMENTS TO FBC.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-12-13 Cont ID  
Sent By rmcdouga Date 2011-12-13 Time 15:16 Rev Time 0.00
Received By rmcdouga Date 2011-12-13 Time 15:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-12-05 Cont ID  
Sent By rmcdouga Date 2011-12-05 Time 15:17 Rev Time 0.00
Received By rmcdouga Date 2011-12-05 Time 15:17 Sent To  
Notes
2011-12-05 15:53:592007 FBC W/2009 REVISIONS
  
 DENIED BY PLUMBING
  
 1) THE PLUMBING SANITARY ISOMETRIC RISER DIAGRAM
 REQUIRED BY CITY AMENDMENTS 106.3.5.4 DOES NOT INCLUDE
 THE NEW 1/2 BATH. PLEASE CORRECT.
  
 2) PLEASE SPECIFY ALL OF THE PIPE SIZES ON THE RISER
 DIAGRAM. FBCR P3005.4
  
 3) ON THE RISER DIAGRAM THERE IS A SECTION OF PIPE NEAR
 THE KITCHEN THAT IS LABELED SINK AND IT IS IN ADDITION
 TO THE KITCHEN SINK. PLEASE CLARIFY. CITY AMENDMENTS
 106.1.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2011-11-15 Cont ID  
Sent By jpapa Date 2011-11-01 Time 13:12 Rev Time 0.00
Received By fmittner Date 2011-11-01 Time 13:15 Sent To  
Notes
2011-11-15 11:25:38LANDSCAPE PLAN SUBMITTED. ONE FLOWERING TREE TO BE
 ADDED BEFORE CO. CONTRACTOR OK WITH ADDITION.