Plan Review Details - Permit 11100420
Plan Review Stops For Permit 11100420
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-02-27 Cont ID  
Sent By rmcdouga Date 2012-02-27 Time 14:22 Rev Time 0.00
Received By rmcdouga Date 2012-02-27 Time 14:22 Sent To  
Notes
2012-02-27 14:23:39SCOPE OF WORK WAS CHANGED TO REPLACEMNET OF THE NEW
 EXTERIOR DOOR ONLY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-02-13 Cont ID  
Sent By rmcdouga Date 2012-02-13 Time 08:07 Rev Time 0.00
Received By rmcdouga Date 2012-02-13 Time 08:07 Sent To  
Notes
2012-02-13 08:08:292007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO CURRENT COPIES OF PRODUCT APPROVALS FOR
 THE EXTERIOR DOOR AS REQUIRED BY DCA RULE 9N-3. THE
 ONES THAT WERE SUBMITTED HAVE BEEN SUPERSEDED. SEE
 COMMENT NUMBER 2 FROM FIRST REVIEW. THE CURRENT
 MIAMI-DADE NOA CAN BE DOWNLOADED AT THIS WEBSITE
 HTTP://WWW.MIAMIDADE.GOV/BUILDING/PC-SEARCH_APP.ASP
  
 2) SPECIFY THE SIZE AND LOCATION OF THE NEW DOOR. FBC
 R301.2.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-11-14 Cont ID  
Sent By rmcdouga Date 2011-11-14 Time 14:20 Rev Time 0.00
Received By rmcdouga Date 2011-11-14 Time 14:20 Sent To  
Notes
2011-11-14 15:01:422007 FBC W/2009 REVISIONS
 REBUILD AND ENCLOSE EXISTING OPEN PORCH
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO CURRENT COPIES OF PRODUCT APPROVALS FOR
 THE WINDOWS, STORM PANELS AND ROOFING MATERIAL AS
 REQUIRED BY DCA RULE 9N-3.
  
 2) SUBMIT TWO CURRENT COPIES OF PRODUCT APPROVALS FOR
 THE EXTERIOR DOOR AS REQUIRED BY DCA RULE 9N-3. THE
 ONES THAT WERE SUBMITTED HAVE BEEN SUPERSEDED.
  
 3) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR
 THE PROJECT. CITY AMENDMENTS 106.3.3
  
 4) ON SHEET A-2 THE ROOF AND WALL COMPONENT AND
 CLADDING PRESSURES ARE TOO LOW FOR EXPOSURE CATEGORY C.
 SEE ASCE7-05 AND FBCR TABLES R301.2(2) & R301.2(3).
 PLEASE CORRECT.
  
 5) THE DRYER IS REQUIRED TO BE VENTED TO THE OUTSIDE OF
 THE BUILDING PER FBCR M1502.1.
  
 6) SPECIFY THE UNDER FLOOR INSULATION REQUIRED BY FBCR
 N1105.AB.1.
  
 7) INDICATE ON THE PLANS HOW COMPLIANCE WITH FBC R408.1
 FOR UNDER-FLOOR SPACE VENTILATION IS ACHIEVED.
  
 8) INDICATE ON THE PLANS HOW COMPLIANCE WITH FBC R
 408.4 FOR ACCESS TO UNDER-FLOOR SPACE IS ACHIEVED.
  
 9) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE
 BATHROOM ADDITION AS REQUIRED BY FBCR N1100.03.
  
 10) PLEASE SUBMIT A RESPONSE LETTER SPECIFYING HOW THE
 PLAN REVIEW COMMENTS HAVE BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-10-27 Cont ID  
Sent By rlecky Date 2011-10-27 Time 16:16 Rev Time 0.00
Received By rlecky Date 2011-10-27 Time 15:59 Sent To  
Notes
2011-10-27 16:18:35INTERCONNECTED SMOKE AND CARBON MONOXIDE ALARMS ARE
 REQUIRED WITHIN THE EXISTING RESIDENCE AS NOTED ON THE
 PLANS. SEE FLORIDA BUILDING CODE RESIDENTIAL SECTION
 R313.

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2012-02-08 Cont ID  
Sent By jroach Date 2012-02-08 Time 15:32 Rev Time 0.00
Received By jroach Date 2012-02-08 Time 15:32 Sent To  
Notes
2012-02-08 15:33:20REVISION (2/8/12) TO PREVIOUS SCOPE OF WORK. NO LONGER
 REMODELING BATHROOM, NEW SCOPE OF WORK ONLY INCLUDES
 REPLACEMENT OF EXTERIOR DOOR.
  
 QUESTIONS/COMMENTS, CONTACT FRIEDERIKE MITTNER,
 561.822.1457.

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2011-10-31 Cont ID  
Sent By jpapa Date 2011-10-31 Time 15:45 Rev Time 0.00
Received By jpapa Date 2011-10-31 Time 15:45 Sent To  
Notes
2011-10-31 15:49:08FAILED.
  
 THE SUBJECT PROPERTY IS LOCATED ON THE WEST PALM BEACH
 REGISTER OF HISTORIC PLACES. THEREFORE, A CERTIFICATE
 OF APPROPRIATENESS IS REQUIRED FOR ANY EXTERIOR
 MODIFICATIONS. PLEASE CONTACT JILLIAN PAPA, HISTORIC
 PRESERVATION PLANNNER AT 561-822-1454 FOR APPLICATION
 REQUIREMENTS.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-02-27 Cont ID  
Sent By rmcdouga Date 2012-02-27 Time 14:23 Rev Time 0.00
Received By rmcdouga Date 2012-02-22 Time 08:15 Sent To  
Notes
2012-02-23 08:16:07SENT TO R MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-02-13 Cont ID  
Sent By rmcdouga Date 2012-02-13 Time 08:23 Rev Time 0.00
Received By rmcdouga Date 2012-02-13 Time 08:23 Sent To  
Notes
2012-02-08 16:49:31TO RM

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-11-17 Cont ID  
Sent By shill Date 2011-11-14 Time 16:55 Rev Time  
Received By shill Date   Time   Sent To  
Notes
2011-10-20 16:09:27R--4

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2012-02-13 Cont ID  
Sent By rmcdouga Date 2012-02-13 Time 08:03 Rev Time 0.00
Received By rmcdouga Date 2012-02-13 Time 08:03 Sent To  
Notes
2012-02-13 08:05:14THE SCOPE OF WORK WAS CHANGED TO ONLY REPLACING AN
 EXTERIOR DOOR.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2011-11-08 Cont ID  
Sent By rmcdouga Date 2011-11-08 Time 16:55 Rev Time 0.00
Received By rmcdouga Date 2011-11-08 Time 16:55 Sent To  
Notes
2011-11-08 16:56:04THE PLANS WILL BE REQUIRED TO BE REVIEWED BY PALM BEACH
 COUNTY FOR IMPACT FEES BEFORE THE PERMIT IS ISSUED. THE
 PLANS WILL BE STAMPED BY THE COUNTY AND RETURNED TO THE
 CITY OF WEST PALM BEACH WITH A COPY OF THE PAID IMPACT
 FEE RECEIPT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2011-11-14 Cont ID  
Sent By rmcdouga Date 2011-11-14 Time 14:17 Rev Time 0.00
Received By rmcdouga Date 2011-11-14 Time 14:17 Sent To  
Notes
2011-11-14 14:18:18NO MECHANICAL PLANS WERE SUBMITTED AND NO MECHANICAL
 CONTRACTOR WAS SIGNED ON TO PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 2 Status N Date 2012-02-13 Cont ID  
Sent By rmcdouga Date 2012-02-13 Time 08:05 Rev Time 0.00
Received By rmcdouga Date 2012-02-13 Time 08:05 Sent To  
Notes
2012-02-13 08:06:40SCOPE OF WORK WAS CHANGED TO ONLY REPLACING AN EXTERIOR
 DOOR.

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-11-08 Cont ID  
Sent By rmcdouga Date 2011-11-08 Time 16:26 Rev Time 0.00
Received By rmcdouga Date 2011-11-08 Time 16:26 Sent To  
Notes
2011-11-08 16:55:032007 FBC W/2009 REVISIONS
  
 DENIED BY PLUMBING
  
 1) PROVIDE PROPER VENTING FOR SHOWER AND LAVATORY. FBCR
 P3101.2 & P3108.2
  
 2) ONLY THE FIXTURES WITHIN THE BATHROOM GROUPS SHALL
 CONNECT TO THE WET-VENTED HORIZONTAL BRANCH DRAIN. THE
 TOILET CAN NOT BE WET-VENTED BY THE WASHING MACHINE
 VENT. SEE FBCR P3108.1 AND P3108.2.
  
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2012-02-08 Cont ID  
Sent By jroach Date 2012-02-08 Time 15:31 Rev Time 0.00
Received By jroach Date 2012-02-08 Time 15:31 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2011-10-31 Cont ID  
Sent By jpapa Date 2011-10-31 Time 15:43 Rev Time 0.00
Received By jpapa Date 2011-10-31 Time 15:43 Sent To  
Notes
2011-10-31 15:45:04FAILED.
  
 PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY?S ADDRESS AND LEGAL DESCRIPTION.
 FOR MORE INFORMATION, PLEASE CONTACT JILLIAN PAPA,
 HISTORIC PRESERVATION PLANNER AT 561-822-1454.