Plan Review Details - Permit 11100384
| Plan Review Stops For Permit 11100384 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-11-14 |
Time |
10:03 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2011-11-14 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2011-11-14 10:20:24 | BUILDING PROVISO: | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES | | | IN THIS PLAN PRIOR TO INSPECTION WILL RESULT IN FAILED | | | INSPECTION(S) AND THE ASSESSMENT | | | OF RE-INSPECTION FEE(S). REVISIONS REQUIRE ADDITIONAL | | | REVIEWS WITH ASSOCIATED FEES. | | | | | | REVISION REQUIRED FOR TRAY CEILING: | | | 1) THE DETAIL SHOWN ( TRAY AT RIGHT ANGLE TO BAR JOIST) | | | VERTICAL LEG OF THE TRAY CEILING TO | | | BE EVERY 24 INCHES ON CENTER, WHAT IS THE ATTACHMENT TO | | | THE BAR JOIST. | | | | | | 2) WHEN THE TRAY CEILING FRAMING IS RUNNING PARALLEL TO | | | THE BAR JOIST WHICH ARE SPACED | | | ANYWHERE FROM 4'-0" TO 6'-0" ON CENTER, HOW WILL THE | | | TRAY CEILING MEMBERS BE | | | ATTACHED IF THERE IS NO BAR JOIST DIRECTLY ABOVE, THERE | | | IS NO STRUCTURAL SUPPORT? | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-10-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-19 |
Time |
09:04 |
Rev Time |
0.70 |
| Received By |
jwitmer |
Date |
2011-10-19 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2011-10-19 09:18:14 | BUILDING PROVISO: | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES | | | IN THIS PLAN PRIOR TO INSPECTION WILL RESULT IN FAILED | | | INSPECTION(S) AND THE ASSESSMENT | | | OF RE-INSPECTION FEE(S). REVISIONS REQUIRE ADDITIONAL | | | REVIEWS WITH ASSOCIATED FEES. | | | | | | REVISION REQUIRED FOR TRAY CEILING: | | | 1) THE DETAIL SHOWN ( TRAY AT RIGHT ANGLE TO BAR JOIST) | | | VERTICAL LEG OF THE TRAY CEILING TO | | | BE EVERY 24 INCHES ON CENTER, WHAT IS THE ATTACHMENT TO | | | THE BAR JOIST. | | | | | | 2) WHEN THE TRAY CEILING FRAMING IS RUNNING PARALLEL TO | | | THE BAR JOIST WHICH ARE SPACED | | | ANYWHERE FROM 4'-0" TO 6'-0" ON CENTER, HOW WILL THE | | | TRAY CEILING MEMBERS BE | | | ATTACHED IF THERE IS NO BAR JOIST DIRECTLY ABOVE, THERE | | | IS NO STRUCTURAL SUPPORT? | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-10-27 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-10-27 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-10-27 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-11-15 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-11-15 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-11-15 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-10-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-10-25 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-10-25 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2011-10-25 10:16:33 | 2021 PALM BEACH LAKES BOULEVARD | | | PERMIT #11100384 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | GENERAL STORAGE ROOMS SHALL BE PROTECTED WITH A 1-HOUR | | | FIRE RATED ENCLOSURE OR AUTOMATIC FIRE SPRINKLERS PER | | | LIFE SAFETY CODE SECTION 37.3.2 AND SECTION 8.7 OF NFPA | | | 101 WITH FLORIDA AMENDMENTS. | | | | | | EXIT ACCESS IN CLASS B MERCATILE OCCUPANCIES IS | | | PERMITTED TO PASS THROUGH STOREROOMS PROVIDED THE | | | STOREROOM DOOR IS NOT SUBJECT TO LOCKING AND A 44-INCH | | | WIDE AISLE IS PROVIDED FROM THE ROOM ENTRANCE DOOR TO | | | THE EXIT DOOR. THE AISLE SHALL BE IDENTIFIED WITH FIXED | | | BARRIERS TO MAINTAIN AN UNOBSTRUCTED EGRESS PATH. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-11-15 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-11-15 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-11-08 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2011-11-08 16:55:32 | SENT TO B2 SHELF FOR REVIEWS. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-11-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-11-01 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-10-18 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2011-11-08 16:34:36 | LAST REVIEW DONE ON 11/01/11 BY ZONING. JG. | | 2011-10-18 16:10:20 | ****************EXPEDITED******************** | | | B--3 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-11-01 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2011-11-01 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2011-11-01 |
Time |
09:25 |
Sent To |
|
|
| Notes |
|
|
|