Plan Review Details - Permit 11100376
Plan Review Stops For Permit 11100376
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-12-16 Cont ID  
Sent By jgomez Date 2011-12-16 Time 09:39 Rev Time 0.00
Received By jgomez Date 2011-12-16 Time 09:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-12-07 Cont ID  
Sent By jgomez Date 2011-12-06 Time 10:27 Rev Time 0.00
Received By jgomez Date 2011-12-06 Time 10:13 Sent To  
Notes
2011-12-06 10:29:00FLAT ROOF BUILDING REVIEW COMMENTS.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- FLAT ROOF RAS 117 CALCULATIONS SUBMITTED:
  
 A) DESIGN PRESSURES SHOWN ARE A LITTLE BIT LOW FOR
 EXPOSURE "C". PLEASE PROVIDE ACTUAL CALCULATIONS TO
 SHOW HOW THE DESIGN PRESSURES WERE OBTAINED. SEC.
 106.1.2 CITY AMENDMENTS TO FBC.
  
 B) REVISE FASTENER SPACING FOR ROOF ZONE #2 (7.5").
 FASTENER SPACING NEEDS TO BE ROUNDED DOWN TO THE NEXT
 WHOLE NUMBER AS REQUIRED BY RAS 117 SEC. 10.4.5.
  
 C) ENGINEER TO CLARIFY WHY REFERENCING TWO DIFFERENT
 NOA'S. ONLY ONE WAS SUBMITTED. ALSO, SPECIFIED
 MATERIALS ARE FOR TAMKO PRODUCTS. SEE GAF NOA SUBMITTED
 AND SPECIFY CORRECT MATERIALS.
  
 D) PROVIDE 2 NEW REVISED RAS 117 CALCULATIONS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-11-03 Cont ID  
Sent By jgomez Date 2011-11-03 Time 15:17 Rev Time 0.00
Received By jgomez Date 2011-11-03 Time 15:17 Sent To  
Notes
2011-11-03 15:26:22RESIDENTIAL (R3) ADDITION, BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. .
  
 2- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTES.
  
 3- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW.
 VALUATION WAS UPDATED AS REQUIRED BY SEC. 108.3 CITY
 AMENDMENTS TO FBC. PERMIT FEE BALANCE DUE IS $539.30.
  
 4- SHEET 1 OF 3:
 A) SPECIFY SAFETY GLASS ON DINING RM WINDOW ADJACENT TO
 THE DOOR AND NEW BATHROOM WINDOW. SEC. R308.4.
  
 B) UPDATE/REVISE DESIGN PARAMETER TABLE: *SPECIFY THE
 FBC 2007 WITH 2009 REVISIONS. **REFERENCE ASCE 7-05 NOT
 ASCE 7-02. ***SPECIFY THE MEAN ROOF HEIGHT. ****SPECIFY
 THE FLAT ROOF SLOPE.
 SEC. 106.1.1 CITY AMENDMENTS TO FBC.
  
 5- SHEET 2 OF 3: UPDATE THE FLORIDA PRODUCT APPROVAL
 NUMBERS SHOWN ON THE TRUSS ANCHOR SCHEDULE. NEED
 NUMBERS FOR 2007 CODE VERSION. VISIT WEBSITE AND REVISE
 AS REQUIRED. AND SPECIFY THE FLORIDA PRODUCT APPROVAL
 FOR ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON THE
 WALL SECTIONS ON SHEET 3 OF 3.
  
 6- SHEET 3 OF 3: A) WALL SECTION "A": CLARIFY WHY ROOF
 INSULATION R-VALUE IS R-1?
  
 B) SPECIFY 7/8" STUCCO THICKNESS AS REQUIRED BY TABLE
 R702.1(1). THIS APPLIES TO ALL WALL SECTIONS SHOWN ON
 THIS SHEET.
  
 C) CLARIFY SIZE OF ANCHOR BOLT SPECIFIED FOR THE WALL
 BOTTOM PLATE. IS IT 1/2" OR 5/8"?. WALL SECTIONS A AND
 B CALLS FOR 5/8" WHILE WALL SECTION C CALLS FOR 1/2".
  
 D) WALL SECTION "B". SPECIFY THE R-VALUE OF ROOF
 INSULATION. SEE ENERGY CALCULATIONS.
  
 E) WALL SECTION C-C: SPECIFY CONTINUOUS ROOF VENT TO
 COMPLY WITH THE CROSS VENTILATION OF SEC. R806.
  
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) WINDOW MULLIONS AS SHOWN ON PLANS.
  
 B) SINGLE HUNG WINDOWS. NOA 06-0706.03 SUBMITTED
 EXPIRED ON OCTOBER 08, 2011.
  
 8- PROVIDE COMPLETE INSTALLATION SCHEDULE FOR THE
 INSTALLATION OF THE STORM PANELS AS REQUIRED BY CITY
 HURRICANE IMPACT PROTECTION POLICY.
  
 9- FLAT ROOF NOA 09-0224.01 SUBMITTED: A) SPECIFY WHICH
 APPROVED ASSEMBLY IS GOING TO BE INSTALLED.
  
 B) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS
 REQUIRED BY GENERAL LIMITATION #7 TO MEET THE DESIGN
 PRESSURES REQUIRED BY SEC. R301.2.1.4.3.
  
 10- ENERGY CALCULATIONS SUBMITTED:
 A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM
 INCLUDING OWNER'S NAME AND REVISE THE JURISDICTION
 NUMBER. THIS JURISDICTION NUMBER IS 604700 NOT 601000.
  
 B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM ALSO.
  
 C) REVISE THE WINDOWS INSTALLED VALUE. ON TABLE 11B-1
 ON SHEET #2. THE U-FACTOR AND SHGC FACTOR NEED TO BE
 EQUAL OR BETTER THAN THE ONE SHOWN ON THE PERFORMANCE
 CRITERIA COLUMN. THE LOWER THE NUMBER THE BETTER THE
 PERFORMANCE. VALUES SHOWN ON THE INSTALLED COLUMN ARE
 HIGHER, THEREFORE MAKING IT WORST THAN THE REQUIRED
 PERFORMANCE CRITERIA. REVISE AS REQUIRED.
  
 D) REVISE THE CHECK (NA) ON THE LAST TWO ITEMS OF TABLE
 11B-2. COORDINATE WITH ITEM #11 BELOW.
  
 11- NEED TO SPECIFY HOW PROVIDING HEATING TO THE NEW
 STUDY LIVABLE SPACE AS REQUIRED BY SEC. R303.8.
 NOTE: PORTABLE HEATERS ARE NOT ALLOWED.
  
 12- PROVIDE COMPLETE OPENING FRAMING DETAILS FOR NEW
 DOORS AND WINDOWS. DRAWINGS ON SHEET 3 OF 3 ARE MISSING
 THE JAMBS INFORMATION AND SPECIFY ALL FASTENERS. SEC.
 106.1.1 CITY AMENDMENTS TO FBC.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-12-07 Cont ID  
Sent By rmcdouga Date 2011-12-07 Time 10:06 Rev Time 0.00
Received By rmcdouga Date 2011-12-07 Time 10:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-10-27 Cont ID  
Sent By rlecky Date 2011-10-27 Time 14:54 Rev Time 0.00
Received By rlecky Date 2011-10-27 Time 14:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-12-16 Cont ID  
Sent By jgomez Date 2011-12-16 Time 09:39 Rev Time 0.00
Received By jgomez Date 2011-12-16 Time 09:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-12-07 Cont ID  
Sent By jgomez Date 2011-12-07 Time 10:28 Rev Time 0.00
Received By jgomez Date 2011-11-28 Time 16:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-11-17 Cont ID  
Sent By shill Date 2011-11-17 Time 16:53 Rev Time 0.00
Received By shill Date 2011-10-17 Time 09:58 Sent To  
Notes
2011-10-25 09:58:02****************EXPEDITED******************
2011-10-18 10:50:29SENT TO R2 SHELF FOR REVIEW BY ALL TRADES. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2011-12-06 Cont ID  
Sent By jgomez Date 2011-12-06 Time 10:35 Rev Time 0.00
Received By jgomez Date 2011-12-06 Time 10:35 Sent To  
Notes
2011-12-06 10:36:20FEES PAID ON 11/16/11. TRACKING NO MU-2011-019705-0000.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2011-11-03 Cont ID  
Sent By jgomez Date 2011-11-03 Time 10:05 Rev Time 0.00
Received By jgomez Date 2011-11-03 Time 10:05 Sent To  
Notes
2011-11-03 10:07:23AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK STAMPED PLANS AND COPY OF THE PAID
 RECEIPT IF FEES ARE DUE. REQUIRED BY COUNTY IMPACT FEE
 ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-12-07 Cont ID  
Sent By jgomez Date 2011-12-07 Time 08:54 Rev Time 0.00
Received By jgomez Date 2011-12-07 Time 08:54 Sent To  
Notes
2011-12-07 08:54:58MECHANICAL PERMIT REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2011-11-03 Cont ID  
Sent By jgomez Date 2011-11-03 Time 14:20 Rev Time 0.00
Received By jgomez Date 2011-11-03 Time 14:20 Sent To  
Notes
2011-11-03 14:21:42NO A/C WORK SHOWN ON PLANS.

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-12-07 Cont ID  
Sent By jgomez Date 2011-12-07 Time 08:55 Rev Time 0.00
Received By jgomez Date 2011-12-07 Time 08:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2011-11-03 Cont ID  
Sent By jgomez Date 2011-11-03 Time 15:16 Rev Time 0.00
Received By jgomez Date 2011-11-03 Time 15:16 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2011-12-05 Cont ID  
Sent By eschneid Date 2011-12-05 Time 15:17 Rev Time 0.25
Received By eschneid Date 2011-12-05 Time 13:49 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2011-11-01 Cont ID  
Sent By eschneid Date 2011-11-01 Time 12:08 Rev Time 0.25
Received By eschneid Date 2011-11-01 Time 12:08 Sent To  
Notes
2011-11-01 12:14:54FAILED
  
 1) TABLE XV-6 OF THE CITY'S ZONING AND LAND DEVELOPMENT
 REGULATIONS REQUIRES THAT SINGLE FAMILY HOUSES HAVE TWO
 PARKING SPACES ON THE PROPERTY. THE ENCLOSURE OF THE
 CARPORT WILL ELIMINATE ONE OF THE TWO EXISTING PARKING
 SPACES ON THE PROPERTY. ZONING CAN NOT APPROVE THIS
 PERMIT UNTIL A BUILDING PERMIT HAS BEEN SUBMITTED TO
 CONSTRUCT A CODE COMPLIANT PARKING SPACE TO REPLACE THE
 ONE REMOVED BY THE ENCLOSURE OF THE CARPORT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.