Plan Review Details - Permit 11100299
Plan Review Stops For Permit 11100299
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2011-10-17 Cont ID  
Sent By jwitmer Date 2011-10-17 Time 15:02 Rev Time 0.55
Received By jwitmer Date 2011-10-17 Time 15:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-10-19 Cont ID  
Sent By rlecky Date 2011-10-19 Time 10:32 Rev Time 0.00
Received By rlecky Date 2011-10-19 Time 10:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-10-24 Cont ID  
Sent By lmartine Date 2011-10-24 Time 15:58 Rev Time 0.00
Received By lmartine Date 2011-10-14 Time 11:15 Sent To  
Notes
2011-10-14 11:16:14INCOMING SENT TO B-12.JW

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-10-14 Cont ID  
Sent By lwagner Date 2011-10-14 Time 16:44 Rev Time 0.00
Received By lwagner Date 2011-10-14 Time 16:14 Sent To  
Notes
2011-10-14 16:22:06*****PROVISO*****
 1. THE POT/DISHWASHER PRE-RINSE SINK REQUIRES A GREASE
 REMOVAL DEVICE.
 1003.3.1 GREASE INTERCEPTORS AND AUTOMATIC GREASE
 REMOVAL DEVICES REQUIRED. A GREASE INTERCEPTOR OR
 AUTOMATIC GREASE REMOVAL DEVICE SHALL BE REQUIRED TO
 RECEIVE THE DRAINAGE FROM FIXTURES AND EQUIPMENT WITH
 GREASE-LADEN WASTE LOCATED IN FOOD PREPARATION AREAS,
 SUCH AS IN RESTAURANTS, HOTEL KITCHENS, HOSPITALS,
 SCHOOL KITCHENS, BARS, FACTORY CAFETERIAS AND CLUBS.
 FIXTURES AND EQUIPMENT SHALL INCLUDE POT SINKS,
 PRERINSE SINKS; SOUP KETTLES OR SIMILAR DEVICES; WOK
 STATIONS; FLOOR DRAINS OR SINKS INTO WHICH KETTLES ARE
 DRAINED; AUTOMATIC HOOD WASH UNITS AND DISHWASHERS
 WITHOUT PRERINSE SINKS. GREASE INTERCEPTORS AND
 AUTOMATIC GREASE REMOVAL DEVICES SHALL RECEIVE WASTE
 ONLY FROM FIXTURES AND EQUIPMENT THAT ALLOW FATS, OILS
 OR GREASE TO BE DISCHARGED.
  
 2. THE DISH WASHER SHALL BE INSTALLED PER MANUF.
 INSTRUCTIONS AND 409.1 APPROVAL. DOMESTIC DISHWASHING
 MACHINES SHALL CONFORM TO ASSE 1006. COMMERCIAL
 DISHWASHING MACHINES SHALL CONFORM TO ASSE 1004 AND NSF
 3.
  
 3. THE DIVISION OF HOTELS AND RESTRAUNTS MAY REQUIRE
 THE WASHING SINK TO BE A 3 COMPARTMENT SINK. OTHER
 REQUIREMENTS MAY ALSO APPLY.
  
 4. THE FRONT PREP SINK, ESPRESSO DRAIN, AND ICE MAKER,
 ETC. ARE REQUIRED TO BE INDIRECT WASTE. A FLOOR SINK
 INSTALLED ABOVE THE FLOOR WOULD BE OK.
 802.1 WHERE REQUIRED. FOOD-HANDLING EQUIPMENT AND
 CLEAR-WATER WASTE SHALL DISCHARGE THROUGH AN INDIRECT
 WASTE PIPE AS SPECIFIED IN SECTIONS 802.1.1 THROUGH
 802.1.7. FIXTURES NOT REQUIRED BY THIS SECTION TO BE
 INDIRECTLY CONNECTED SHALL BE DIRECTLY CONNECTED TO THE
 PLUMBING SYSTEM IN ACCORDANCE WITH CHAPTER 7.
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR