Plan Review Details - Permit 11100243
| Plan Review Stops For Permit 11100243 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-11-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-11-03 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-11-03 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-10-26 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-26 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2011-10-26 10:49:37 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PROVIDE AN ENGINEERED DETAIL WHICH SHOWS COMPLIANCE | | | WITH FBC R 312.2. | | | | | | 2. ENGINEERED DETAIL SHOULD STATE DESIGN CRITERIA, SEE | | | FBC R TABLE 301.5. | | | | | | 3. PROVIDE A FLOOR PLAN WHICH SHOWS PROPOSED LOCATION | | | OF RAILINGS, DOOR, AND GARAGE DOOR. | | | | | | 4. PROVIDE MORE INFORMATION REGARDING THE RAILING ABOVE | | | THE FRONT DOOR. PHOTOGRAPHS SHOW WHAT APPEARS TO BE A | | | JULIETTE BALCONY, PLAN PROPOSES A 22" HIGH RAILING, BUT | | | NO OTHER INFORMATION PROVIDED, SEE FBC R 312.2. IT IS | | | NOT CLEAR WHETHER THERE IS A DOOR AT THIS LOCATION. | | | PLANS (NOT PHOTOGRAPHS) SHOULD CLEARLY SHOW CODE | | | COMPLIANCE, SEE FBC 106.1.1, | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-10-26 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-12 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2011-10-26 10:36:31 | PLAN SIGNED BY JP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-11-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-11-03 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-31 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2011-10-31 10:02:05 | TO SH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-10-26 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-13 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2011-10-13 08:00:54 | SENT TO S. HILL |
|
|
|