Plan Review Details - Permit 11100221
| Plan Review Stops For Permit 11100221 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-11-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-11-29 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-11-29 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-10-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-10-18 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-18 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2011-10-18 08:45:34 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. SEE INSTALLATION SCHEDULE SUBMITTED, OPENING 1. A 3" | | | EDGE DISTANCE, 120" OPENING, WOULD HAVE A SPAN OF 123" | | | MINIMUM. THIS COMMENT APPLIES TO ALL OPENINGS. | | | | | | 2. SEE OPENING 1, "1" IS NOTED AS THE MOUNTING | | | CONNECTION TYPE. THIS IS A HEADER CONNECTION. WALL | | | MOUNT 3 (SILL) IS HIGHLIGHTED ON THE PRODUCT APPROVAL. | | | A SPAN OF 11' REQUIRES 8" ANCHOR SPACING FOR DESIGN | | | PRESSURE UP TO 40. PLEASE REVISE AND CHECK ALL | | | (ESPECIALLY OPENINGS WITH DESIGN PRESSURE GREATER THAN | | | 40). | | | | | | ANOTHER EXAMPLE, OPENING 2, WALL MOUNT 3 (HIGHLIGHTED) | | | REQUIRES 7" ANCHOR SPACING FOR DP UP TO 60, OPENING UP | | | TO 8'. | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
N |
Date |
2011-10-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-10-11 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-11 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2011-10-11 12:58:17 | HISTORIC REVIEW FROM ANOTHER ADDRESS PREVIOUSLY | | | ASSIGNED TO THIS PERMIT # (NOW VOIDED) | | | ADDRESS NOT HISTORIC | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2011-10-18 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-10-11 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-11 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2011-10-11 12:41:35 | FAILED. | | | | | | CHANGE IN EXTERIOR FINISH REQUIRES HISTORIC | | | PRESERVATION BOARD APPROVAL. ALTERNATIVELY, THE | | | EXTERIOR WOOD SIDING MAY BE REPAIRED AND/OR REPLACED AS | | | NEEDED WITH WOOD (LIKE) MATERIAL. FOR MORE INFORMATION, | | | CONTACT JILLIAN PAPA, HISTORIC PRESERVATION PLANNER AT | | | 561-822-1454. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-11-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-11-29 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-11-14 |
Time |
15:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-11-29 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-11-18 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-11 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2011-10-11 12:58:48 | MISC 1 | | | |
|
|
|