Plan Review Details - Permit 11100165
Plan Review Stops For Permit 11100165
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-12-20 Cont ID  
Sent By jgomez Date 2011-12-20 Time 11:11 Rev Time 0.00
Received By jgomez Date 2011-12-20 Time 11:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-11-04 Cont ID  
Sent By jgomez Date 2011-11-04 Time 17:29 Rev Time 0.00
Received By jgomez Date 2011-11-04 Time 13:51 Sent To  
Notes
2011-11-04 17:34:55RESIDENTIAL (R3) RENOVATION BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.
 **NOTE: THIS MAY BE RECORDED A TIME OF PERMIT PICK UP.
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ALL EXTERIOR DOORS AS SHOWN ON PLANS, INCLUDING THE
 SHED DOUBLE DOORS.
  
 B) ALL WINDOWS AS SHOWN ON PLANS. INCLUDING THE LARGE
 FIXED WINDOW SHOWN ON WEST ELEVATION ON SHEET A-1.
  
 C) ALL STRUCTURAL DOOR/WINDOW MULLIONS AS SHOWN ON
 PLANS. AND, CLEARLY SELECT MULLION SIZE FOR WINDOW AND
 DOOR TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF
 SEC. R301.2.1.4.3. SEE LARGE FIXED WINDOW ON WEST
 ELEVATION.
  
 D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS/DETAILS. PROVIDE ONLY THE PRODUCT APPROVAL COVER
 PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR. THIS
 APPLIES TO STRUCTURAL CONNECTORS ONLY.
  
 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC.
  
 4- DEMOLITION NOTE #3 ON THE COVER SHEET CALLS FOR
 REMOVAL OF SCREEN AT CRAWL SPACE. NOTE #9 ON SHEET A-1
 CALLS FOR NEW CRAWL SPACE OPENING ON NORTH WALL.
 PROVIDE COMPLETE INFORMATION SHOWING HOW COMPLYING WITH
 THE UNDER FLOOR SPACE VENTILATION REQUIREMENTS AS
 REQUIRED BY SEC. R408. SEE SEC. R408.1 FOR VENTILATION
 CALCULATIONS AND LOCATION OF OPENINGS. REVISE PLANS AS
 REQUIRED.
  
 ***NOTE: REVISE/COORDINATE WITH MECHANICAL PLAN.
 EXISTING A/C CONDENSER UNITS WILL BLOCK THE VENTILATION
 OPENING.
  
 5- PROVIDE COMPLETE INFORMATION FOR FIREPLACE UNDER A
 SEPARATE PERMIT. SEE NOTE #15 ON SHEET A-1. THIS WORK
 IS NOT INCLUDED ON THIS PLANS.
  
 6- SPECIFY CARBON MONOXIDE ALARMS AS REQUIRED BY SEC.
 R313.4.
  
 7- ENGINEER SIGNING AND SEALING THE STRUCTURAL DRAWINGS
 TO PROVIDE HIS NAME AND LICENSE NUMBER AS REQUIRED BY
 CHAPTER 471 FLORIDA STATUTE AND SEC. 61G15-23.002
 FLORIDA ADMINISTRATIVE CODE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-01-04 Cont ID  
Sent By rlecky Date 2012-01-04 Time 09:09 Rev Time 0.00
Received By rlecky Date 2012-01-04 Time 08:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-10-19 Cont ID  
Sent By rlecky Date 2011-10-19 Time 15:28 Rev Time 0.00
Received By rlecky Date 2011-10-19 Time 13:54 Sent To  
Notes
2011-10-19 15:28:5011100165
 2416 MEDINA WAY
 INTERIOR RESIDENTIAL RENOVATION
  
 VERIFY THE EXISTING LIVING ROOM BEING RENOVATED HAS
 RECEPTACLES PROPERLY SPACED. NEC 210.52
 VERIFY OR PROVIDE SMOKE DETECTORS AND CARBON MONOXIDE
 DETECTORS AS REQUIRED FOR ADDITIONS AND RENOVATIONS.
 FBC R 313.2.1, R313.4
 VERIFY THAT COUNTER TOP RECEPTACLES ARE GFCI PROTECTED
 AND DISTRIBUTED APPROPRIATELY. NEC 210.8, 210.52
 VERIFY OR PROVIDE A GFCI PROTECTED RECEPTACLE ON THE
 NEW TERRACE. NEC 210.8
 PROVIDE SPECIFICATIONS ON THE TERRACE CEILING FANS
 INDICATING THE EQUIPMENT IS SUITABLE FOR USE IN A DAMP
 LOCATION. NEC 110.11
  
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2011-12-19 Cont ID  
Sent By fmittner Date 2011-12-19 Time 15:07 Rev Time 0.00
Received By fmittner Date 2011-12-19 Time 15:07 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2011-10-13 Cont ID  
Sent By jpapa Date 2011-10-13 Time 16:27 Rev Time 0.00
Received By jpapa Date 2011-10-13 Time 16:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-01-04 Cont ID  
Sent By rlecky Date 2012-01-04 Time 09:14 Rev Time 0.00
Received By rlecky Date 2011-12-08 Time 09:02 Sent To  
Notes
2011-12-09 09:02:1212/9/11 SENT TO R10 SHELF FOR REVIEW. JG.
  
  
2011-12-08 16:12:32GAVE TO JULIO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-11-04 Cont ID  
Sent By jgomez Date 2011-11-04 Time 17:47 Rev Time 0.00
Received By jgomez Date 2011-10-14 Time 10:11 Sent To  
Notes
2011-10-14 10:11:51INCOMING SENT TO R-1 BOX. JW

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-12-20 Cont ID  
Sent By jgomez Date 2011-12-20 Time 12:02 Rev Time 0.00
Received By jgomez Date 2011-12-20 Time 12:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-11-04 Cont ID  
Sent By jgomez Date 2011-11-04 Time 17:06 Rev Time 0.00
Received By jgomez Date 2011-11-04 Time 17:05 Sent To  
Notes
2011-11-04 17:11:36MECHANICAL REVIEW CHECKLIST:
  
 1- CLARIFY WHAT'S THE DIFFERENCE BETWEEN DRAWING M2 AND
 M3. THEY SEEM TO HAVE THE SAME INFORMATION.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-12-20 Cont ID  
Sent By jgomez Date 2011-12-20 Time 12:00 Rev Time 0.00
Received By jgomez Date 2011-12-20 Time 12:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-11-17 Cont ID  
Sent By jgomez Date 2011-11-04 Time 17:27 Rev Time 0.00
Received By jgomez Date 2011-11-04 Time 17:27 Sent To  
Notes
2011-11-17 09:11:32PLUMBING REVIEW COMMENTS:
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PROVIDE PLUMBING RISER DIAGRAM. SEC. 106.3.5.4 CITY
 AMENDMENTS TO FBC.
  
 2- PROVIDE COMPLETE INFORMATION FOR GAS WORK UNDER A
 SEPARATE PERMIT.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 2 Status P Date 2011-12-19 Cont ID  
Sent By fmittner Date 2011-12-19 Time 15:07 Rev Time 0.00
Received By fmittner Date 2011-12-19 Time 15:07 Sent To  
Notes
2011-12-19 15:07:29R10

Review Stop Z ZONING
Rev No 1 Status P Date 2011-10-18 Cont ID  
Sent By jpapa Date 2011-10-18 Time 15:35 Rev Time 0.00
Received By jpapa Date 2011-10-18 Time 15:35 Sent To  
Notes
2011-10-18 15:57:46PROVISO:
  
 PER SECTION 94-305 OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS, THE PROPOSED NEW SLAB SHALL NOT EXCEED 3'
 IN HEIGHT, AS MEASURE FROM GRADE AND SHALL BE
 STRUCTURALLY RETAINED AND POSITIVELY DRAINED IN AMANNER
 THAT WILL PREVENT ANY DRAINAGE DISCHARGE TO ANY
 PROPERTY CONTIGUOUS TO THE SIDE (NORTH) PROPERTY LINE.
  
 FOR MORE INFORMATION, PLEASE CONTACT JILLIAN PAPA,
 HISTORIC PRESERVATION PLANNER AT 561-822-1454.