Plan Review Details - Permit 11100142
| Plan Review Stops For Permit 11100142 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-26 |
Time |
09:08 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2011-10-26 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-10-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-12 |
Time |
15:32 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2011-10-12 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2011-10-12 15:42:09 | BUILDING PLAN REVIEW | | | PERMIT: 11100142 | | | ADD: 400 N FLAGLER # 1805 | | | CONT: GUARDIAN CONSTRUCTION | | | TEL: (561)308-2569 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PLANS FAIL TO PROVIDE INFORMATION ON THE NEW INFILE | | | CEILING. PLEASE PROVIDE TYPE OF CEILING FRAMING, IF | | | METAL TYPE OF CEILING JOIST. SIZE OF FRAMING MEMBER, | | | GAUGE, SPACING AAND THE TYPE OF CEILING FINISH WITH | | | THICKNESS. FBC-B 2508.1 AND TABLE 2508.1. | | | | | | 2) PLANS ALSO WILL NEED TO PROVIDE A FINISH CEILING | | | HEIGHT. FBC-B 1208.2. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-10-19 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-10-19 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-10-19 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2011-10-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-10-20 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-10-20 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-26 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2011-10-24 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2011-10-24 15:50:10 | SENT TO JIM'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-10-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-10-20 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-10-11 |
Time |
12:18 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |