Plan Review Details - Permit 11100060
| Plan Review Stops For Permit 11100060 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2012-02-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-02-02 |
Time |
09:05 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2012-02-02 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-26 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2011-10-26 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2011-10-26 08:38:18 | BUILDING PLAN REVIEW | | | PERMIT: 11100060 | | | ADD: 105 S NARCISSUS ST | | | CONT: HAYDEN | | | TEL: (772)485-5000 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) COPIES SENT OF WIND STUDY DO NOT HAVE ORIGINAL | | | SIGNATURES, THEY ARE COPIES. | | | | | | 2) THE PLANS DO NOT INDICATE ANYWHWERE HOW ANY MEMBERS | | | WILL BE ANCHORED AGAINST WIND, MOMENT OF OVERTURNING, | | | SLIDDING ETC. THE RESPONCE INDICATED THEY WILL BE | | | FASTENED PER MANUFACTURERS SPECIFICATIONS PLEASE | | | PRODUCE THE MANUFACTURERS SPEC SHOWING THE ANCHORS FOR | | | 140 MPH WIND AND REVIEWED BY THE DESIGNER OF RECORD | | | WITH SHOP DRAWING STAMP. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-10-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-17 |
Time |
13:32 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2011-10-17 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2011-10-17 13:42:37 | BUILDING PLAN REVIEW | | | PERMIT: 11100060 | | | ADD: 105 S NARCISSUS ST | | | CONT: HAYDEN | | | TEL: (772)485-5000 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) THE LETTER FROM CITY SCAPE INDICATES A WIND LOAD | | | STUDY WAS CONDUCTED USING THE LATEST STANDARDS FROM | | | EIA/TIA-222-G. NO WIND STUDY WAS INCLUDED WITHIN THE | | | PERMIT PACKAGE. PLEASE SUBMIT THE BROADCAST STRUCTURES | | | ANSI/ EIA/ TIA-222-G STUDY SINCE IT IS ONE OF THE | | | REFRENECED STANDARDS AND WIND DESIGN CRITERIA | | | EXCEPTIONS LISTED UNDER THE 2007/09 FBC-B 1609.1.1 | | | EXCEPTION # 6. | | | | | | 2) THE PLANS DO NOT INDICATE ANYWHWERE HOW ANY MEMBERS | | | WILL BE ANCHORED AGAINST WIND, MOMENT OF OVERTURNING, | | | SLIDDING ETC. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-10-18 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-10-18 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-10-18 |
Time |
14:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-02-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-02-02 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-02-01 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-26 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2011-10-25 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2011-10-25 12:28:14 | GAVE TO JIM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-10-18 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-10-18 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-10-05 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2011-10-05 16:44:45 | INCOMING SENT TO C-13. JW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-10-14 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2011-10-14 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2011-10-14 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |