| Plan Review Stops For Permit 11090682 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-11-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-11-21 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-11-21 |
Time |
17:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-10-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-10-31 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-31 |
Time |
08:53 |
Sent To |
FIRE |
|
| Notes |
| 2011-10-31 09:10:19 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | (REVISED 11/1 AFTER ARCHITECT'S EMAIL 10/31, REQUESTED | | | MISSING INFORMATION FROM CONTRACTOR VIA EMAIL) | | | | | | 1. PER ARCHITECT - MAIN DOOR TO COMPLY WITH EXCEPTION | | | FBC 1008.1.8.3. | | | | | | PLEASE PROVIDE CLARIFICATION, DOOR 2 IS SHOWN AS | | | EXISTING WITH PANIC HARDWARE, MY UNDERSTANDING IS THAT | | | THIS DOOR IS TO BE REPLACED. EITHER REVISE PLAN TO | | | INCLUDE THIS DOOR AS NEW, OR CONFIRM THAT EXISTING IS | | | TO REMAIN AND CURRENTLY HAS PANIC HARDWARE AS STATED ON | | | THE SCHEDULE. | | | | | | PER FIRE, ONLY THE MAIN DOOR FALLS UNDER THE EXCEPTION, | | | NOT DOOR #8. | | | | | | PLEASE PROVIDE EITHER A MIAMIDADE NOA OR A FLORIDA | | | STATE PRODUCT APPROVAL COVER SHEET FOR THE DOOR. ONLY | | | EVALUATION REPORT WAS SUBMITTED FOR THE DOOR, NO | | | FLORIDA STATE PRODUCT APPROVAL NUMBER WAS PROVIDED, | | | FAC9N-3. | | | | | | PROVIDE PRODUCT APPROVAL FOR THE PROPOSED DOOR(S) WHICH | | | REQUIRE PANIC HARDWARE, FAC9N-3. | | | | | | 2. ADDRESSED. | | | | | | 3. PROVIDE A MORE ACCURATE ADDITIONAL COST FOR THE | | | STOREFRONT SYSTEM AND DOORS. | | | | | | $4000 IS NOT A REASONABLE VALUE FOR THE IMPACT | | | STOREFRONT SYSTEM AND THREE SETS OF IMPACT DOORS. | | | PROVIDE VALUE OF MATERIALS AND LABOR FOR INSTALLATION, | | | FBC 108.3. | | | | | | ***PLEASE ADVISE IF CONTRACTOR WOULD LIKE FOR THE | | | MECHANICAL PORTION OF THE REVISION TO BE ISSUED | | | SEPARATELY** | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-10-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-10-05 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-05 |
Time |
12:11 |
Sent To |
FIRE |
|
| Notes |
| 2011-10-05 12:15:15 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. SEE FBC EB 705.4.4 REGARDING PANIC DEVICES IN | | | ASSEMBLY OCCUPANCY; PLEASE REVISE THE DOOR SCHEDULE ON | | | SHEET A170.1. | | | | | | 2. PROVIDE SIZE AND CONFIGURATION OF THE STOREFRONT | | | SYSTEM OR CIRCLE THE OPTIONS PROPOSED ON THE PRODUCT | | | APPROVAL, FBC1609. | | | | | | 3. PROVIDE A MORE ACCURATE ADDITIONAL COST FOR THE | | | STOREFRONT SYSTEM AND DOORS. | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2011-11-16 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-11-16 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-11-16 |
Time |
10:39 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2011-11-01 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-11-01 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-11-01 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2011-11-01 14:42:22 | 330 CLEMATIS STREET #107 | | | TRACKING #11090682 | | | PERMIT #11070649 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PER SECTION 12.2.2.2.4 (FFPC) ONLY THE MAIN ENTRY IS | | | PERMITTED TO BE EQUIPPED WITH A KEYED LOCK WITH | | | LOCK/UNLOCK INDICATOR WINDOW AND SIGNAGE STATING THE | | | DOOR IS TO REMAIN UNLOCKED DURING BUSINESS HOURS. PREP | | | AREA DOORS (#8) NEED TO RELEASE THE LOCK/LATCH WITH | | | EITHER A LEVER OR PANIC HARDWARE. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-10-05 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-10-05 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-10-05 |
Time |
14:02 |
Sent To |
M |
|
| Notes |
| 2011-10-05 14:25:49 | 330 CLEMATIS STREET #107 | | | TRACKING #11090682 | | | PERMIT #11070649 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | A THUMB TURN STYLE LOCK IS NOT PERMITTED ON THE MAIN | | | ENTRY DOOR(S). MAIN ENTRY IS PERMITTED TO BE EQUIPPED | | | WITH A KEYED LOCK WITH LOCK/UNLOCK INDICATOR WINDOW AND | | | SIGNAGE STATING THE DOOR IS TO REMAIN UNLOCKED DURING | | | BUSINESS HOURS. NO OTHER LOCKING OR LATCHING MECHANISMS | | | ARE PERMITTED. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-11-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-11-21 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-11-14 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2011-11-14 14:58:45 | TO FIRE BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-11-01 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-11-01 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-10-31 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2011-10-31 09:11:54 | **EXPEDITED 2ND RUN** | | | | | | 10/31 ROUTED 1ST & 2ND REVISION SUBMITTALS TO FIRE | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-10-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-10-11 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-09-28 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2011-09-28 16:24:56 | ****************EXPEDITED******************** | | 2011-09-28 16:24:27 | IN ZONING BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2011-10-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-10-11 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-10-11 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2011-10-11 08:20:29 | OK PER HM | | | REVISION 9/23 SHEET M0.1 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-10-04 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2011-10-04 |
Time |
16:38 |
Rev Time |
0.50 |
| Received By |
aaponte |
Date |
2011-09-30 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2011-10-04 16:38:42 | PROVISO: DARK TINTED OR REFLECTIVE GLASS NOT PERMITTED. |
|
|