| Plan Review Stops For Permit 11090496 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-26 |
Time |
16:17 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2011-10-26 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-09-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-09-23 |
Time |
15:20 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2011-09-23 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-10-27 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-10-27 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-10-27 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-09-21 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-09-21 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-09-21 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-10-26 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-10-26 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2011-09-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-09-29 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-09-29 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2011-09-29 13:46:39 | 801 NORTHPOINT PARKWAY - SUITE #1 | | | PERMIT #11090496 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE NEW FIRE RATED DOOR PROVIDED IN THE 1-HOUR FIRE | | | BARRIER OF CONFERENCE ROOM #10 SHOULD BE A 45-MINUTE | | | FIRE RATED DOOR, NOT A 20-MINUTE FIRE RATED DOOR. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | SHEET E-2: THE DOOR TO CONFERENCE ROOM #10 IS SHOWN AS | | | AN EXIT DOOR, VERIFY THIS DOOR IS NOT SUBJECT TO | | | LOCKING. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-11-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-11-02 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-10-24 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2011-10-24 14:22:28 | SENT TO B14 FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-09-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-09-29 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-09-20 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-11-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-11-02 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-11-02 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2011-09-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-09-27 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-09-27 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2011-09-27 14:17:54 | PASS PROVISO | | | PROVIDE A LETTER FROM THE ENGINEER HOW FAR APART ARE | | | THE 3/8 BOLTS ARE TO BE . | | | FOR THE CURB TO ROOF TIE DOWN ON PAGE M-3. | | | FOR ROUGH INSPECTION. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-10-27 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-10-27 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-10-27 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2011-09-22 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-09-22 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-09-22 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2011-09-22 11:49:28 | NO PLUMBING DRAWINGS WERE INCLUDED WITH MASTER SET. | | | SEPARATE APPLICATION, DRAWING, PERMIT IS REQUIRED IF | | | INSTALLING NEW DRINKING FOUNTAIN. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2011-11-01 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-11-01 |
Time |
13:53 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2011-11-01 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2011-11-01 13:53:55 | NEW A/C SETBACKS NOTED ON THE PLAN. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-09-26 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-09-26 |
Time |
15:52 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2011-09-26 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2011-09-26 16:01:53 | FAILED | | | | | | 1) PLEASE PROVIDE EVIDENCE AS TO HOW THE NEW ROOFTOP | | | A/C EQUIPMENT WILL BE SCREENED. THIS SHOULD INCLUDE THE | | | HEIGHT OF THE EQUIPMENT AND THE HEIGHT OF THE | | | SCREENING. | | | | | | PLEASE CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|