| Plan Review Stops For Permit 11090467 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2013-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-01-25 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-01-25 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2012-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-07-11 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-07-11 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-03-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-27 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-27 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2012-03-27 14:01:52 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO SETS OF PRODUCT APPROVALS OR SITE | | | SPECIFIC ENGINEERING FOR THE TWO 8' X 8' CUSTOM | | | OUTSWING DOORS AS REQUIRED BY DCA RULE 9N-3. THE CUSTOM | | | DOORS ARE REQUIRED TO MEET COMPONENT AND CLADDING | | | WINDLOAD PRESSURES PER FBC R301.2.1. | | | | | | 2) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE | | | FUNCTIONAL STORM SHUTTERS SPECIFIED ON SHEET A-3.0 AS | | | REQUIRED BY DCA RULE 9N-3 AND FBC R301.2.1. | | | | | | 3) SUBMIT TWO SETS OF INSTALLATION SCHEDULES FOR THE | | | GARAGE DOOR STORM PANELS AND THE FUNCTIONAL STORM | | | SHUTTERS IN ORDER TO VERIFY WINDLOAD REQUIREMENTS OF | | | FBC R301.2.1. | | | | | | 4) THE VALUE OF THE PROJECT SPECIFIED ON THE PERMIT | | | APPLICATION IS LOW. FOR PERMITTING PURPOSES THE VALUE | | | IS BASED ON THE CURRENT CONSTRUCTION COSTS AS IF THE | | | WORK WAS BEING DONE BY A LICENSED CONTRACTOR AND | | | INCLUDES ALL RELATED COSTS INCLUDING DESIGN FEES, | | | LABOR, MATERIAL, OVERHEAD AND PROFIT PER CITY | | | AMENDMENTS 108.3. THE CALCULATED COST OF THE NEW | | | DETACHED GARAGE AND THE AREA ADDED TO THE EXISTING TWO | | | STORY DWELLING IS $ 80, 412.04. THIS DOES NOT INCLUDE | | | THE COST OF REMODELING THE EXISTING PART OF THE TWO | | | STORY DWELLING. PLEASE PROVIDE AN APPROPRIATE VALUE | | | BASED ON THE INFORMATION PROVIDED. | | | | | | 5) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW THE | | | REVIEW COMMENTS WILL BE ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-12-01 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-11-30 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2011-12-01 07:48:35 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) ALL OF THE PLANS FROM THE ARCHITECT AND ENGINEER | | | WITH THEIR TITLE BLOCKS ARE REQUIRED TO BE SIGNED AND | | | SEALED IN ACCORDANCE WITH FAC 61G1-16.001 AND FAC | | | 61G15-23.002. | | | | | | 2) SHOW LOCATION OF SMOKE ALARM AND CARBON MONOXIDE | | | DETECTOR IN THE BONUS ROOM AS REQUIRED BY FBC R313.2.1 | | | AND R313.4. | | | | | | 3) SPECIFY THE TOTAL OF ADDITIONAL LIVING AREA ON THE | | | PLANS. CITY AMENDMENTS FBC 106.1.2 | | | | | | 4) ON SHEET A-0.0 UNDER CODE SUMMARY, THE BOCA RATON | | | CITY AMENDMENTS ARE SPECIFIED RATHER THAN THE CITY OF | | | WEST PALM BEACH AMENDMENTS. PLEASE CORRECT. | | | | | | 5) ON SHEET A-0.0 UNDER CODE SUMMARY, THE OCCUPANCY IS | | | SPECIFIED AS R1A RATHER THAN R3. PLEASE CORRECT. SEE | | | FBC 310.1. | | | | | | 6) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE TWO | | | STORY DWELLING UNIT AND THE BONUS ROOM ABOVE THE GARAGE | | | AS REQUIRED BY THE 2007 FBC ENERGY AMENDMENTS SECTION | | | N1100.3. | | | | | | 7) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | ROOFING MATERIALS, COR-A-VENTS, GARAGE DOORS, STORM | | | SHUTTERS AND OTHER EXTERIOR COMPONENTS AND CLADDING AS | | | REQUIRED BY DCA RULE 9N-3. CITY AMENDMENT FBC 106.3.3 | | | REQUIRES PRODUCT APPROVALS TO BE REVIEWED AND APPROVED | | | IN WRITING BY THE DESIGNER OF RECORD. ONLY ONE COPY OF | | | THE WINDOW AND DOOR PRODUCT APPROVALS WERE SUBMITTED. | | | THE DOOR SCHEDULE ON SHEET A-3.0 OF THE PLANS SPECIFIES | | | NOA NO. 09-1028.10 FOR THE FRENCH DOORS, HOWEVER, THE | | | ONE THAT WAS SUBMITTED AND APPROVED BY HISTORIC REVIEW | | | IS NOA NO. 07-0629.10. | | | | | | 8) SUBMIT TWO SETS OF STRUCTURAL DRAWINGS FOR THE | | | PROPOSED WORK. INCLUDE WALL SECTION FROM FOUNDATION | | | THROUGH ROOF ( INCLUDING ASSEMBLY AND MATERIALS), | | | CONNECTOR TABLES AND WIND REQUIREMENTS. CITY AMENDMENTS | | | FBC 106.3.5.4 | | | | | | 9) PROVIDE TWO SETS OF FOUNDATION PLANS, FIRST AND | | | SECOND FLOOR FRAMING PLAN AND ROOF FRAMING PLAN. CITY | | | AMENDMENTS FBC 106.1.1 AND 106.1.1.2 | | | | | | 10) SPECIFY THE REQUIRED OPENING PRESSURES ON THE | | | PLANS. | | | | | | 11) SPECIFY THE ROOF AND WALL SHEATHING FASTENING | | | REQUIREMENTS ON THE PLANS. FBC R602.3 AND R803.2.3.1 | | | | | | 12) PROVIDE WINDOW AND DOOR BUCK FASTENING | | | REQUIREMENTS. FBC R613.6.1.1 | | | | | | 13) SHOW COMPLIANCE WITH FBC R 408.3 AND R408.4 FOR | | | CRAWL SPACE VENTILATION AND ACCESS. | | | | | | 14) SHOW COMPLIANCE WITH FBC R 703.6.2 AND ASTM C 1063 | | | SECTION 7.11.5 WHICH REQUIRES A FOUNDATION WEEP SCREED | | | AT THE BOTTOM OF ALL FRAMED EXTERIOR WALLS, BELOW THE | | | FLOOR LINE. | | | | | | 15) SPECIFY THE DESIGN CRITERIA ON THE PLANS IN | | | ACCORDANCE WITH R301.2.1.1. SPECIFY THE WIND SPEED, | | | EXPOSURE CATEGORY, DESIGN PRESSURES, REQUIRED SOIL | | | BEARING CAPACITY, ROOF AND FLOOR LOADS, ETC. | | | | | | 16) THE WINDOWS IN UPSTAIRS BEDROOMS 2 AND 3 DO NOT | | | COMPLY WITH FBC R310 FOR EMERGENCY ESCAPE AND RESCUE | | | CLEAR OPENING SIZES. PLEASE CORRECT. | | | | | | 17) THE GAS WATER HEATER IN THE UPSTAIRS MASTER BEDROOM | | | W.I.C. IS IN A PROHIBITED LOCATION ACCORDING TO FBCR | | | G2406.2 (303.3) . SHOW COMPLIANCE WITH G2406.2 ON THE | | | PLANS. | | | | | | 18) SHOW HOW THE REQUIREMENTS OF FBCR SECTION G2407 | | | (304) FOR COMBUSTION, VENTILATION AND DILUTION AIR FOR | | | THE GAS APPLIANCES WILL BE MET. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-03-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-27 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-26 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-12-01 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-12-01 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2011-12-01 08:48:28 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY ELECTRICAL | | | | | | 1) ONLY ONE SET OF ELECTRICAL PLANS WERE SUBMITTED. | | | PLEASE SUBMIT 2 SETS OF DRAWINGS. CITY AMENDMENTS FBC | | | 106.1 | | | | | | 2) PLANS FROM AN ARCHITECT OR ENGINEER WITH THEIR TITLE | | | BLOCKS ARE REQUIRED TO BE SIGNED AND SEALED IN | | | ACCORDANCE WITH FAC 61G1-16.001 AND FAC 61G15-23.002. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2012-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-26 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-26 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2011-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-12-01 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-12-01 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2012-03-26 11:05:48 | NO GAS CONTRACTOR SIGNED ON APPLICATION. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-11-18 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-11-18 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-11-18 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-09-27 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-09-27 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-09-27 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2011-09-27 11:28:43 | FAILED. | | | | | | 1. PER HPB 11-33, THE WOOD SHINGLES SHALL BE RETAINED | | | AND REPAIRED AS NEEDED. THE WOOD SHINGLES MAY BE | | | REPLACED IN KIND ONLY WHERE THE EXISTING MATERIAL IS | | | SEVERELY DETERIORATED. THE ELEVATIONS SUBMITTED FOR | | | BUILDING PERMIT ARE UNCLEAR AS TO WHERE NEW MATERIAL IS | | | TO BE INSTALLED AND WHERE THE EXISTING SHINGLES WILL BE | | | RETAINED. PLEASE SUBMIT PRODUCT INFORMATION ON CEDAR | | | SHAKES FOR REVIEW. | | | 2. THE PROPOSED WINDOW PRODUCT SHALL BE APPROVED BY | | | STAFF BASED UPON A REVIEW OF THE EVIDENCE SUGGESTED | | | THAT THE ORIGINAL PRODUCT WAS A 4/4 PANE CONFIGURATION. | | | PLEASE SUBMIT PHOTOGRAPHS TO BE KEPT ON RECORD. | | | 3. THE APPLICANT SHALL SUBMIT WINDOW AND DOOR PRODUCT | | | APPROVALS FOR ADMINISTRATIVE REVIEW PRIOR TO SUBMITTAL | | | FOR A BUILDING PERMIT. WINDOWS SHALL HAVE CLEAR GLASS, | | | WHITE FRAMES AND DIMENSIONAL EXTERIOR MUNTINS. | | | | | | FOR MORE INFORMATION, PLEASE CONTACT JILLIAN PAPA, | | | HISTORIC PRESERVATION PLANNER AT 561-822-1454. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2013-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-01-25 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-01-15 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2013-01-17 13:48:16 | SENT TO MCDOUGAL'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2012-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-07-11 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-06-29 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2012-07-10 11:14:16 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-27 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-16 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-12-01 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-11-21 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2011-11-21 16:34:50 | ***************EXPEDITED**************** | | | R--7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-11-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-11-17 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-11-17 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2011-11-17 16:48:46 | 11/17/11 CLOSED "I" STOP FOR REPORTING PURPOSES | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2012-03-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-27 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-27 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2012-03-27 15:06:10 | BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. 233-5025 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2011-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-11-30 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-11-30 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2011-11-30 15:03:40 | BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. 233-5025 |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2011-11-18 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-11-18 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-11-18 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2012-07-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-07-10 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-07-10 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2012-07-10 13:25:06 | REVISION REQUIRED: THE ENERGY CALCULATIONS THAT WERE | | | SUBMITTED FOR THE GARAGE BONUS ROOM ARE BASED ON THE | | | 2010 FBC AND THIS PROJECT IS PERMITTED UNDER THE 2007 | | | FBC. SUBMIT TWO COPIES OF THE 2007 FBC ENERGY | | | CALCULATIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2012-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-26 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-26 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2012-03-26 16:58:14 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY MECHANICAL | | | | | | 1) THE MECHANICAL PLANS ON SHEET A-5.0 HAVE THE TITLE | | | BLOCK OF THE ARCHITECT ON THEM AND ARE NOT SIGNED AND | | | SEALED BY HIM AS REQUIRED BY FLORIDA STATUTES SECTION | | | 481 AND F.A.C.61G1-16.004. THE MECHANICAL PLANS DO NOT | | | HAVE TO BE DESIGNED BY AN ARCHITECT OR ENGINEER. THE | | | MECHANICAL CONTRACTOR CAN DESIGN THE SYSTEM AND PROVIDE | | | HIS NAME AND LICENSE NUMBER AND CONTACT NUMBER ON THE | | | PLAN. THE ARCHITECT'S TITLE BLOCK MUST BE REMOVED FROM | | | THE MECHANICAL PLANS IF HE IS NOT TAKING DESIGN | | | RESPONSIBILITY BY SIGNING AND SEALING THEM. | | | | | | 2) THE DUCTWORK SPECIFIED TO BE INSTALLED UNDER THE | | | HOUSE SHALL NOT BE LOCATED WITHIN 4 INCHES OF THE EARTH | | | IN ACCORDANCE WITH FBCR M1601.3.10. | | | | | | 3) SECTION N 1100.0 REQUIRES ENERGY CALCULATIONS FOR | | | THE NEW BONUS ROOM ABOVE THE GARAGE. THE ELECTRICAL | | | PLANS INDICATE THAT IT HAS BEEN DESIGNED TO ACCOMMODATE | | | THE FUTURE INSTALLATION OF HEATING OR COOLING | | | EQUIPMENT. | | | | | | 4) THE ENERGY CALC. FORMS ARE REQUIRED TO BE SIGNED BY | | | THE OWNER/AGENT. 2007 FBC ENERGY GLITCH AMENDMENTS | | | N1100.2.2. | | | | | | 5) SHOW COMPLIANCE WITH FBC M1701.1 FOR COMBUSTION AIR | | | FOR THE GAS WATER HEATER AND DRYER IN THE SECOND FLOOR | | | LAUNDRY ROOM. THE GAS RISER SHOWS THE WATER HEATER IS | | | 199,000 BTU AND THE DRYER IS 25,000 BTU. IN ORDER FOR | | | ALL AIR FROM INSIDE THE BUILDING TO BE USED THE VOLUME | | | OF THE SPACE CONTAINING THE FUEL BURNING EQUIPMENT IS | | | REQUIRED TO BE GREATER THAN 50 CUBIC FEET PER 1,000 | | | BTU. THE LAUNDRY ROOM IS TOO SMALL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-12-01 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-12-01 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2011-12-01 07:41:28 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY MECHANICAL | | | | | | 1) NO MECHANICAL PLANS WERE SUBMITTED. PLEASE SUBMIT | | | TWO SETS OF MECHANICAL PLANS WITH AN EQUIPMENT | | | SCHEDULE, DUCT LAYOUT, DUCT SIZES & GRILL SIZES. CITY | | | AMENDMENTS FBC 106.3.5.4 | | | | | | 2) SUBMIT TWO SETS OF EQUIPMENT SIZING LOAD | | | CALCULATIONS AS REQUIRED BY FBCR M1401.3. | | | | | | 3) SUBMIT TWO SETS OF ENERGY CALCULATIONS IN ACCORDANCE | | | WITH 2007 FBC ENERGY AMENDMENTS SECTION N1100.3. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-03-26 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-03-26 |
Time |
11:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-11-30 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-11-30 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2011-11-30 16:54:21 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY PLUMBING | | | | | | 1) ONLY ONE SET OF PLUMBING PLANS WERE SUBMITTED. | | | PLEASE SUBMIT 2 SETS OF DRAWINGS. CITY AMENDMENTS FBC | | | 106.1 | | | | | | 2) PLANS FROM AN ARCHITECT OR ENGINEER WITH THEIR TITLE | | | BLOCKS ARE REQUIRED TO BE SIGNED AND SEALED IN | | | ACCORDANCE WITH FAC 61G1-16.001 AND FAC 61G15-23.002. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2011-11-18 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-11-18 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-11-18 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-09-27 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-09-27 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-09-27 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2011-09-27 11:49:21 | FAILED. | | | | | | 1. THE BUILDING HEIGHT SHALL BE MEASURED ACCORDING TO | | | SEC. 94-79(A)(3) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS, WHICH STATES, "OVERALL HEIGHT IS MEASURED | | | AS THE VERTICAL DISTANCE IN FEET FROM FINISHED GRADE TO | | | THE HIGHEST POINT OF THE ROOF FOR FLAT ROOFS; TO THE | | | DECK LINE FOR MANSARD ROOFS; AND TO THE AVERAGE HEIGHT | | | BETWEEN EAVES AND THE RIDGE FOR GABLE, HIP AND GAMBREL | | | ROOFS. WHERE FINISHED GRADE IS MORE THAN TWO FEET ABOVE | | | NATURAL GRADE, OVERALL HEIGHT SHALL BE MEASURED FROM | | | TWO FEET ABOVE NATURAL GRADE. FINISHED GRADE SHALL NOT | | | EXCEED REQUIRED MINIMUM FLOOD REGULATIONS. SEE SECTION | | | 94-306 FOR LIMITED HEIGHT EXCEPTIONS." | | | | | | 2. IN ACCORDANCE WITH SECTION 94-85(F)(5) OF THE ZLDRS, | | | THE ITEMS DEMONSTRATING THE USE OF GREEN BUILDING | | | PRACTICES MUST BE INCLUDED IN THE PLANS FOR | | | CONSTRUCTION. PLEASE REVIEW THE ITEMS LISTED IN THE | | | JUSTIFICATION STATEMENT SUBMITTED FOR HPB 11-33 AND | | | NOTE THEM IN THE PERTINENT IRRIGATION, LANDSCAPING, | | | PLUMBING AND ELECTRICAL PLANS. | | | | | | 3. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF | | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDR. | | | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE ZLDR. | | | | | | FOR MORE INFORMATION, PLEASE CONTACT JILLIAN PAPA, | | | HISTORIC PRESERVATION PLANNER AT 561-822-1454. | | | | | | | | | |
|
|