Plan Review Details - Permit 11090467
Plan Review Stops For Permit 11090467
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2013-01-31 Cont ID  
Sent By rmcdouga Date 2013-01-25 Time 13:31 Rev Time 0.00
Received By rmcdouga Date 2013-01-25 Time 13:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-07-11 Cont ID  
Sent By rmcdouga Date 2012-07-11 Time 10:37 Rev Time 0.00
Received By rmcdouga Date 2012-07-11 Time 10:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-03-27 Cont ID  
Sent By rmcdouga Date 2012-03-27 Time 13:43 Rev Time 0.00
Received By rmcdouga Date 2012-03-27 Time 06:57 Sent To  
Notes
2012-03-27 14:01:522007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO SETS OF PRODUCT APPROVALS OR SITE
 SPECIFIC ENGINEERING FOR THE TWO 8' X 8' CUSTOM
 OUTSWING DOORS AS REQUIRED BY DCA RULE 9N-3. THE CUSTOM
 DOORS ARE REQUIRED TO MEET COMPONENT AND CLADDING
 WINDLOAD PRESSURES PER FBC R301.2.1.
  
 2) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE
 FUNCTIONAL STORM SHUTTERS SPECIFIED ON SHEET A-3.0 AS
 REQUIRED BY DCA RULE 9N-3 AND FBC R301.2.1.
  
 3) SUBMIT TWO SETS OF INSTALLATION SCHEDULES FOR THE
 GARAGE DOOR STORM PANELS AND THE FUNCTIONAL STORM
 SHUTTERS IN ORDER TO VERIFY WINDLOAD REQUIREMENTS OF
 FBC R301.2.1.
  
 4) THE VALUE OF THE PROJECT SPECIFIED ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING PURPOSES THE VALUE
 IS BASED ON THE CURRENT CONSTRUCTION COSTS AS IF THE
 WORK WAS BEING DONE BY A LICENSED CONTRACTOR AND
 INCLUDES ALL RELATED COSTS INCLUDING DESIGN FEES,
 LABOR, MATERIAL, OVERHEAD AND PROFIT PER CITY
 AMENDMENTS 108.3. THE CALCULATED COST OF THE NEW
 DETACHED GARAGE AND THE AREA ADDED TO THE EXISTING TWO
 STORY DWELLING IS $ 80, 412.04. THIS DOES NOT INCLUDE
 THE COST OF REMODELING THE EXISTING PART OF THE TWO
 STORY DWELLING. PLEASE PROVIDE AN APPROPRIATE VALUE
 BASED ON THE INFORMATION PROVIDED.
  
 5) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW THE
 REVIEW COMMENTS WILL BE ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-12-01 Cont ID  
Sent By rmcdouga Date 2011-12-01 Time 11:15 Rev Time 0.00
Received By rmcdouga Date 2011-11-30 Time 07:11 Sent To  
Notes
2011-12-01 07:48:352007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) ALL OF THE PLANS FROM THE ARCHITECT AND ENGINEER
 WITH THEIR TITLE BLOCKS ARE REQUIRED TO BE SIGNED AND
 SEALED IN ACCORDANCE WITH FAC 61G1-16.001 AND FAC
 61G15-23.002.
  
 2) SHOW LOCATION OF SMOKE ALARM AND CARBON MONOXIDE
 DETECTOR IN THE BONUS ROOM AS REQUIRED BY FBC R313.2.1
 AND R313.4.
  
 3) SPECIFY THE TOTAL OF ADDITIONAL LIVING AREA ON THE
 PLANS. CITY AMENDMENTS FBC 106.1.2
  
 4) ON SHEET A-0.0 UNDER CODE SUMMARY, THE BOCA RATON
 CITY AMENDMENTS ARE SPECIFIED RATHER THAN THE CITY OF
 WEST PALM BEACH AMENDMENTS. PLEASE CORRECT.
  
 5) ON SHEET A-0.0 UNDER CODE SUMMARY, THE OCCUPANCY IS
 SPECIFIED AS R1A RATHER THAN R3. PLEASE CORRECT. SEE
 FBC 310.1.
  
 6) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE TWO
 STORY DWELLING UNIT AND THE BONUS ROOM ABOVE THE GARAGE
 AS REQUIRED BY THE 2007 FBC ENERGY AMENDMENTS SECTION
 N1100.3.
  
 7) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 ROOFING MATERIALS, COR-A-VENTS, GARAGE DOORS, STORM
 SHUTTERS AND OTHER EXTERIOR COMPONENTS AND CLADDING AS
 REQUIRED BY DCA RULE 9N-3. CITY AMENDMENT FBC 106.3.3
 REQUIRES PRODUCT APPROVALS TO BE REVIEWED AND APPROVED
 IN WRITING BY THE DESIGNER OF RECORD. ONLY ONE COPY OF
 THE WINDOW AND DOOR PRODUCT APPROVALS WERE SUBMITTED.
 THE DOOR SCHEDULE ON SHEET A-3.0 OF THE PLANS SPECIFIES
 NOA NO. 09-1028.10 FOR THE FRENCH DOORS, HOWEVER, THE
 ONE THAT WAS SUBMITTED AND APPROVED BY HISTORIC REVIEW
 IS NOA NO. 07-0629.10.
  
 8) SUBMIT TWO SETS OF STRUCTURAL DRAWINGS FOR THE
 PROPOSED WORK. INCLUDE WALL SECTION FROM FOUNDATION
 THROUGH ROOF ( INCLUDING ASSEMBLY AND MATERIALS),
 CONNECTOR TABLES AND WIND REQUIREMENTS. CITY AMENDMENTS
 FBC 106.3.5.4
  
 9) PROVIDE TWO SETS OF FOUNDATION PLANS, FIRST AND
 SECOND FLOOR FRAMING PLAN AND ROOF FRAMING PLAN. CITY
 AMENDMENTS FBC 106.1.1 AND 106.1.1.2
  
 10) SPECIFY THE REQUIRED OPENING PRESSURES ON THE
 PLANS.
  
 11) SPECIFY THE ROOF AND WALL SHEATHING FASTENING
 REQUIREMENTS ON THE PLANS. FBC R602.3 AND R803.2.3.1
  
 12) PROVIDE WINDOW AND DOOR BUCK FASTENING
 REQUIREMENTS. FBC R613.6.1.1
  
 13) SHOW COMPLIANCE WITH FBC R 408.3 AND R408.4 FOR
 CRAWL SPACE VENTILATION AND ACCESS.
  
 14) SHOW COMPLIANCE WITH FBC R 703.6.2 AND ASTM C 1063
 SECTION 7.11.5 WHICH REQUIRES A FOUNDATION WEEP SCREED
 AT THE BOTTOM OF ALL FRAMED EXTERIOR WALLS, BELOW THE
 FLOOR LINE.
  
 15) SPECIFY THE DESIGN CRITERIA ON THE PLANS IN
 ACCORDANCE WITH R301.2.1.1. SPECIFY THE WIND SPEED,
 EXPOSURE CATEGORY, DESIGN PRESSURES, REQUIRED SOIL
 BEARING CAPACITY, ROOF AND FLOOR LOADS, ETC.
  
 16) THE WINDOWS IN UPSTAIRS BEDROOMS 2 AND 3 DO NOT
 COMPLY WITH FBC R310 FOR EMERGENCY ESCAPE AND RESCUE
 CLEAR OPENING SIZES. PLEASE CORRECT.
  
 17) THE GAS WATER HEATER IN THE UPSTAIRS MASTER BEDROOM
 W.I.C. IS IN A PROHIBITED LOCATION ACCORDING TO FBCR
 G2406.2 (303.3) . SHOW COMPLIANCE WITH G2406.2 ON THE
 PLANS.
  
 18) SHOW HOW THE REQUIREMENTS OF FBCR SECTION G2407
 (304) FOR COMBUSTION, VENTILATION AND DILUTION AIR FOR
 THE GAS APPLIANCES WILL BE MET.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-03-27 Cont ID  
Sent By rmcdouga Date 2012-03-27 Time 09:51 Rev Time 0.00
Received By rmcdouga Date 2012-03-26 Time 14:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-12-01 Cont ID  
Sent By rmcdouga Date 2011-12-01 Time 08:56 Rev Time 0.00
Received By rmcdouga Date 2011-12-01 Time 07:48 Sent To  
Notes
2011-12-01 08:48:282007 FBC W/2009 REVISIONS
  
 DENIED BY ELECTRICAL
  
 1) ONLY ONE SET OF ELECTRICAL PLANS WERE SUBMITTED.
 PLEASE SUBMIT 2 SETS OF DRAWINGS. CITY AMENDMENTS FBC
 106.1
  
 2) PLANS FROM AN ARCHITECT OR ENGINEER WITH THEIR TITLE
 BLOCKS ARE REQUIRED TO BE SIGNED AND SEALED IN
 ACCORDANCE WITH FAC 61G1-16.001 AND FAC 61G15-23.002.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]
  
  
  
  
  
  
  
  
  
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2012-03-26 Cont ID  
Sent By rmcdouga Date 2012-03-26 Time 11:04 Rev Time 0.00
Received By rmcdouga Date 2012-03-26 Time 11:04 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2011-12-01 Cont ID  
Sent By rmcdouga Date 2011-12-01 Time 16:03 Rev Time 0.00
Received By rmcdouga Date 2011-12-01 Time 16:03 Sent To  
Notes
2012-03-26 11:05:48NO GAS CONTRACTOR SIGNED ON APPLICATION.

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2011-11-18 Cont ID  
Sent By jpapa Date 2011-11-18 Time 14:38 Rev Time 0.00
Received By jpapa Date 2011-11-18 Time 14:37 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2011-09-27 Cont ID  
Sent By jpapa Date 2011-09-27 Time 11:19 Rev Time 0.00
Received By jpapa Date 2011-09-27 Time 11:19 Sent To  
Notes
2011-09-27 11:28:43FAILED.
  
 1. PER HPB 11-33, THE WOOD SHINGLES SHALL BE RETAINED
 AND REPAIRED AS NEEDED. THE WOOD SHINGLES MAY BE
 REPLACED IN KIND ONLY WHERE THE EXISTING MATERIAL IS
 SEVERELY DETERIORATED. THE ELEVATIONS SUBMITTED FOR
 BUILDING PERMIT ARE UNCLEAR AS TO WHERE NEW MATERIAL IS
 TO BE INSTALLED AND WHERE THE EXISTING SHINGLES WILL BE
 RETAINED. PLEASE SUBMIT PRODUCT INFORMATION ON CEDAR
 SHAKES FOR REVIEW.
 2. THE PROPOSED WINDOW PRODUCT SHALL BE APPROVED BY
 STAFF BASED UPON A REVIEW OF THE EVIDENCE SUGGESTED
 THAT THE ORIGINAL PRODUCT WAS A 4/4 PANE CONFIGURATION.
 PLEASE SUBMIT PHOTOGRAPHS TO BE KEPT ON RECORD.
 3. THE APPLICANT SHALL SUBMIT WINDOW AND DOOR PRODUCT
 APPROVALS FOR ADMINISTRATIVE REVIEW PRIOR TO SUBMITTAL
 FOR A BUILDING PERMIT. WINDOWS SHALL HAVE CLEAR GLASS,
 WHITE FRAMES AND DIMENSIONAL EXTERIOR MUNTINS.
  
 FOR MORE INFORMATION, PLEASE CONTACT JILLIAN PAPA,
 HISTORIC PRESERVATION PLANNER AT 561-822-1454.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2013-01-31 Cont ID  
Sent By rmcdouga Date 2013-01-25 Time 13:31 Rev Time 0.00
Received By rmcdouga Date 2013-01-15 Time 13:47 Sent To  
Notes
2013-01-17 13:48:16SENT TO MCDOUGAL'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2012-07-11 Cont ID  
Sent By rmcdouga Date 2012-07-11 Time 10:37 Rev Time 0.00
Received By rmcdouga Date 2012-06-29 Time 11:13 Sent To  
Notes
2012-07-10 11:14:16SENT TO R MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-03-29 Cont ID  
Sent By rmcdouga Date 2012-03-27 Time 15:05 Rev Time 0.00
Received By rmcdouga Date 2012-03-16 Time 10:30 Sent To  
Notes
2012-03-16 10:31:09RM

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-12-01 Cont ID  
Sent By rmcdouga Date 2011-12-01 Time 11:30 Rev Time 0.00
Received By rmcdouga Date 2011-11-21 Time 16:34 Sent To  
Notes
2011-11-21 16:34:50***************EXPEDITED****************
 R--7

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-11-17 Cont ID  
Sent By shill Date 2011-11-17 Time 16:22 Rev Time 0.00
Received By shill Date 2011-11-17 Time 16:48 Sent To  
Notes
2011-11-17 16:48:4611/17/11 CLOSED "I" STOP FOR REPORTING PURPOSES
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2012-03-27 Cont ID  
Sent By rmcdouga Date 2012-03-27 Time 15:05 Rev Time 0.00
Received By rmcdouga Date 2012-03-27 Time 15:05 Sent To  
Notes
2012-03-27 15:06:10BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION. 233-5025

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2011-11-30 Cont ID  
Sent By rmcdouga Date 2011-11-30 Time 15:03 Rev Time 0.00
Received By rmcdouga Date 2011-11-30 Time 15:02 Sent To  
Notes
2011-11-30 15:03:40BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION. 233-5025

Review Stop L LANDSCAPING
Rev No 1 Status P Date 2011-11-18 Cont ID  
Sent By jpapa Date 2011-11-18 Time 14:39 Rev Time 0.00
Received By jpapa Date 2011-11-18 Time 14:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2012-07-10 Cont ID  
Sent By rmcdouga Date 2012-07-10 Time 13:18 Rev Time 0.00
Received By rmcdouga Date 2012-07-10 Time 13:18 Sent To  
Notes
2012-07-10 13:25:06REVISION REQUIRED: THE ENERGY CALCULATIONS THAT WERE
 SUBMITTED FOR THE GARAGE BONUS ROOM ARE BASED ON THE
 2010 FBC AND THIS PROJECT IS PERMITTED UNDER THE 2007
 FBC. SUBMIT TWO COPIES OF THE 2007 FBC ENERGY
 CALCULATIONS.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2012-03-26 Cont ID  
Sent By rmcdouga Date 2012-03-26 Time 16:26 Rev Time 0.00
Received By rmcdouga Date 2012-03-26 Time 16:26 Sent To  
Notes
2012-03-26 16:58:142007 FBC W/2009 REVISIONS
  
 DENIED BY MECHANICAL
  
 1) THE MECHANICAL PLANS ON SHEET A-5.0 HAVE THE TITLE
 BLOCK OF THE ARCHITECT ON THEM AND ARE NOT SIGNED AND
 SEALED BY HIM AS REQUIRED BY FLORIDA STATUTES SECTION
 481 AND F.A.C.61G1-16.004. THE MECHANICAL PLANS DO NOT
 HAVE TO BE DESIGNED BY AN ARCHITECT OR ENGINEER. THE
 MECHANICAL CONTRACTOR CAN DESIGN THE SYSTEM AND PROVIDE
 HIS NAME AND LICENSE NUMBER AND CONTACT NUMBER ON THE
 PLAN. THE ARCHITECT'S TITLE BLOCK MUST BE REMOVED FROM
 THE MECHANICAL PLANS IF HE IS NOT TAKING DESIGN
 RESPONSIBILITY BY SIGNING AND SEALING THEM.
  
 2) THE DUCTWORK SPECIFIED TO BE INSTALLED UNDER THE
 HOUSE SHALL NOT BE LOCATED WITHIN 4 INCHES OF THE EARTH
 IN ACCORDANCE WITH FBCR M1601.3.10.
  
 3) SECTION N 1100.0 REQUIRES ENERGY CALCULATIONS FOR
 THE NEW BONUS ROOM ABOVE THE GARAGE. THE ELECTRICAL
 PLANS INDICATE THAT IT HAS BEEN DESIGNED TO ACCOMMODATE
 THE FUTURE INSTALLATION OF HEATING OR COOLING
 EQUIPMENT.
  
 4) THE ENERGY CALC. FORMS ARE REQUIRED TO BE SIGNED BY
 THE OWNER/AGENT. 2007 FBC ENERGY GLITCH AMENDMENTS
 N1100.2.2.
  
 5) SHOW COMPLIANCE WITH FBC M1701.1 FOR COMBUSTION AIR
 FOR THE GAS WATER HEATER AND DRYER IN THE SECOND FLOOR
 LAUNDRY ROOM. THE GAS RISER SHOWS THE WATER HEATER IS
 199,000 BTU AND THE DRYER IS 25,000 BTU. IN ORDER FOR
 ALL AIR FROM INSIDE THE BUILDING TO BE USED THE VOLUME
 OF THE SPACE CONTAINING THE FUEL BURNING EQUIPMENT IS
 REQUIRED TO BE GREATER THAN 50 CUBIC FEET PER 1,000
 BTU. THE LAUNDRY ROOM IS TOO SMALL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-12-01 Cont ID  
Sent By rmcdouga Date 2011-12-01 Time 07:28 Rev Time 0.00
Received By rmcdouga Date 2011-12-01 Time 07:28 Sent To  
Notes
2011-12-01 07:41:282007 FBC W/2009 REVISIONS
  
 DENIED BY MECHANICAL
  
 1) NO MECHANICAL PLANS WERE SUBMITTED. PLEASE SUBMIT
 TWO SETS OF MECHANICAL PLANS WITH AN EQUIPMENT
 SCHEDULE, DUCT LAYOUT, DUCT SIZES & GRILL SIZES. CITY
 AMENDMENTS FBC 106.3.5.4
  
 2) SUBMIT TWO SETS OF EQUIPMENT SIZING LOAD
 CALCULATIONS AS REQUIRED BY FBCR M1401.3.
  
 3) SUBMIT TWO SETS OF ENERGY CALCULATIONS IN ACCORDANCE
 WITH 2007 FBC ENERGY AMENDMENTS SECTION N1100.3.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-03-26 Cont ID  
Sent By rmcdouga Date 2012-03-26 Time 11:05 Rev Time 0.00
Received By rmcdouga Date 2012-03-26 Time 11:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-11-30 Cont ID  
Sent By rmcdouga Date 2011-11-30 Time 16:51 Rev Time 0.00
Received By rmcdouga Date 2011-11-30 Time 16:51 Sent To  
Notes
2011-11-30 16:54:212007 FBC W/2009 REVISIONS
  
 DENIED BY PLUMBING
  
 1) ONLY ONE SET OF PLUMBING PLANS WERE SUBMITTED.
 PLEASE SUBMIT 2 SETS OF DRAWINGS. CITY AMENDMENTS FBC
 106.1
  
 2) PLANS FROM AN ARCHITECT OR ENGINEER WITH THEIR TITLE
 BLOCKS ARE REQUIRED TO BE SIGNED AND SEALED IN
 ACCORDANCE WITH FAC 61G1-16.001 AND FAC 61G15-23.002.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2011-11-18 Cont ID  
Sent By jpapa Date 2011-11-18 Time 14:38 Rev Time 0.00
Received By jpapa Date 2011-11-18 Time 14:38 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2011-09-27 Cont ID  
Sent By jpapa Date 2011-09-27 Time 11:31 Rev Time 0.00
Received By jpapa Date 2011-09-27 Time 11:31 Sent To  
Notes
2011-09-27 11:49:21FAILED.
  
 1. THE BUILDING HEIGHT SHALL BE MEASURED ACCORDING TO
 SEC. 94-79(A)(3) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS, WHICH STATES, "OVERALL HEIGHT IS MEASURED
 AS THE VERTICAL DISTANCE IN FEET FROM FINISHED GRADE TO
 THE HIGHEST POINT OF THE ROOF FOR FLAT ROOFS; TO THE
 DECK LINE FOR MANSARD ROOFS; AND TO THE AVERAGE HEIGHT
 BETWEEN EAVES AND THE RIDGE FOR GABLE, HIP AND GAMBREL
 ROOFS. WHERE FINISHED GRADE IS MORE THAN TWO FEET ABOVE
 NATURAL GRADE, OVERALL HEIGHT SHALL BE MEASURED FROM
 TWO FEET ABOVE NATURAL GRADE. FINISHED GRADE SHALL NOT
 EXCEED REQUIRED MINIMUM FLOOD REGULATIONS. SEE SECTION
 94-306 FOR LIMITED HEIGHT EXCEPTIONS."
  
 2. IN ACCORDANCE WITH SECTION 94-85(F)(5) OF THE ZLDRS,
 THE ITEMS DEMONSTRATING THE USE OF GREEN BUILDING
 PRACTICES MUST BE INCLUDED IN THE PLANS FOR
 CONSTRUCTION. PLEASE REVIEW THE ITEMS LISTED IN THE
 JUSTIFICATION STATEMENT SUBMITTED FOR HPB 11-33 AND
 NOTE THEM IN THE PERTINENT IRRIGATION, LANDSCAPING,
 PLUMBING AND ELECTRICAL PLANS.
  
 3. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 FOR MORE INFORMATION, PLEASE CONTACT JILLIAN PAPA,
 HISTORIC PRESERVATION PLANNER AT 561-822-1454.
  
  
  