Plan Review Details - Permit 11090023
Plan Review Stops For Permit 11090023
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-09-22 Cont ID  
Sent By lmartine Date 2011-09-22 Time 14:36 Rev Time 0.00
Received By lmartine Date 2011-09-22 Time 14:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-09-09 Cont ID  
Sent By shill Date 2011-09-09 Time 16:09 Rev Time 0.00
Received By shill Date 2011-09-09 Time 16:09 Sent To  
Notes
2011-09-09 16:18:35****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 COMMENTS FROM PREVIOUS LIST:
  
 1. ADDRESSED
  
 2. ENHANCED FASTENING FOR THE FLAT DECKS REQUIRE
 CALCULATIONS BY AN ARCHITECT, ENGINEER, OR REGISTERED
 ROOF CONSULTANT, SEE GENERAL LIMITATION #7, LAST PAGE
 OF PRODUCT APPROVAL.
  
 2ND REVIEW, THE DESIGN PRESSURES SPECIFIED BY ARCHITECT
 COLETTE SATCHELL ARE TOO LOW. SEE FBC RAS 127, FBC
 RESIDENTIAL TABLE 301.2(2) AND (3). THIS STRUCTURE IS
 LOCATED IN 140MPH EXPOSURE C, PRESSURES OF -47.66,
 -55.01, -73.6 ARE TOO LOW. SEE ALSO ASCE7-05, SECTION
 6.2, DEFINITION OF "EFFEECTIVE WIND AREA", FOR CLADDING
 FASTENERS, THE EFFECTIVE WIND AREA SHALL NOT BE GREATER
 THAN THE AREA THAT IS TRIBUTARY TO AN INDIVIDUAL
 FASTENER. THEREFORE, AREA IS < 10' FOR ALL ZONES.
 PLEASE FEEL FREE TO CONTACT ME TO DISCUSS.
  
 NEW COMMENT:
  
 3. THE NEW SHINGLE PRODUCT APPROVALS ARE TO BE REVIEWED
 BY HISTORIC PRIOR TO RESUBMITTAL.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-09-07 Cont ID  
Sent By shill Date 2011-09-07 Time 09:53 Rev Time 0.00
Received By shill Date 2011-09-07 Time 09:53 Sent To  
Notes
2011-09-07 09:58:27****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLEASE INDICATE WHICH APPROVED ASSEMBLY IS PROPOSED.
  
 2. ENHANCED FASTENING FOR THE FLAT DECKS REQUIRE
 CALCULATIONS BY AN ARCHITECT, ENGINEER, OR REGISTERED
 ROOF CONSULTANT, SEE GENERAL LIMITATION #7, LAST PAGE
 OF PRODUCT APPROVAL.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2011-09-14 Cont ID  
Sent By jpapa Date 2011-09-14 Time 16:58 Rev Time 0.00
Received By jpapa Date 2011-09-14 Time 16:58 Sent To  
Notes
2011-09-14 16:58:59APPROVAL OF ROOF REPLACEMENT ONLY.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2011-09-01 Cont ID  
Sent By jpapa Date 2011-09-01 Time 14:29 Rev Time 0.00
Received By jpapa Date 2011-09-14 Time 16:58 Sent To  
Notes
***NONE***