Plan Review Details - Permit 11080740
| Plan Review Stops For Permit 11080740 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-09-14 |
Time |
10:31 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2011-09-14 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2011-09-14 10:32:18 | STRUCTURAL: M-7A DETAILS # 12 & 13 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-09-13 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-09-13 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-09-12 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2011-10-24 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2011-10-24 |
Time |
|
Rev Time |
0.50 |
| Received By |
|
Date |
2011-10-24 |
Time |
|
Sent To |
|
|
| Notes |
| 2011-10-24 13:01:38 | PLAN IS ACCEPTABLE | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-10-26 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-10-26 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-08-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-08-29 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-08-29 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2011-08-29 14:25:36 | 8740 STATE ROAD 7 | | | PERMIT #11080740 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NO ADDRESS PROVIDED ON DRAWINGS. | | | | | | PROVIDE MATERIAL SAFETY DATA SHEETS (MSDS) FOR 19% | | | AMMONIA HYDROXIDE. | | | | | | INDICATE IF THE BUILDING IS PROTECTED BY AN AUTOMATIC | | | FIRE SPRINKLER SYSTEM. | | | | | | CONFIRM THE TOTAL QUANTITY OF AMMONIA HYDROXIDE TO BE | | | LOCATED IN THE ROOM IS 320 GALLONS (TANK #1 - 155 | | | GALLONS, TANK #2 - 55 GALLONS, SPARE TANK - 55 GALLONS | | | (X2)). | | | | | | VERIFY AMMONIA HYDROXIDE ROOM IS SEPARATED FROM | | | ADJACENT CHLORINE ROOM WITH A FIRE RESISTANCE RATING OF | | | AT LEAST ONE-HOUR. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
P |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-10-26 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-10-26 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2011-10-26 13:51:17 | IN FIRE BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-10-24 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-10-24 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-08-29 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2011-08-29 10:14:26 | SENT TO C1 SHELF FOR ALL TRADES REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2011-09-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-09-22 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-09-22 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2011-09-01 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-09-01 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-09-01 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-09-19 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2011-09-19 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2011-09-19 |
Time |
17:40 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |